1143971.1 |
|
Sun Fire 3800/4800/4810/6800/E4900/E6900/v1280/E2900 or Netra 1280/1290: System Controller reports TOD BATTERY LOW FLAG SET |
2010-07-13
|
1019667.1 |
243326 |
Sun Fire[TM] Server System Board (SB) voltage errors. |
2011-04-25
|
1018948.1 |
230806 |
Sun Fire[TM] Serengeti: System Board power on generates "JTAG part 0x91a0: Substituting version 0x3 for version 0x4" |
2010-07-07
|
1018832.1 |
230625 |
Sun Fire[TM] Midframe servers: POST fails during IOPOST, marking all I/O Boards (IBs) as bad. |
2010-07-07
|
1018813.1 |
230603 |
Sun Fire[TM] 3800-6800: Domains running firmware 5.15.x or later with hang-policy set to "notify" may lose critical troubleshooting data |
2010-06-15
|
1018620.1 |
230316 |
Sun Fire [TM] Midrange Server: inaccurate msg from the SC following a reboot |
2010-07-07
|
1018210.1 |
229578 |
Sun Fire[TM] Midframe Server:Symptom:Flashupdate fails when user is root-No boards can be updated |
2010-05-21
|
1018097.1 |
229413 |
Problems loading Solaris[TM] on Sun Fire[TM](3800-6800) system with swap > 4GB |
2009-09-29
|
1017987.1 |
229265 |
Response to error: SepromSegment(constructor): PE at 0x----: Invalid CRC observed=xxxxxxxx expected=yyyyyyyy |
2010-07-06
|
1017926.1 |
229185 |
Sun Fire[TM] 3800-6800: Troubleshooting NCPQ_TO errors |
2010-07-15
|
1017844.1 |
229081 |
Sun Fire[TM] MidRange Server I/O Board (IB) power supply failures. |
2011-02-03
|
1017808.1 |
229038 |
send break does not always work on Sun Fire[TM] platform |
2010-08-20
|
1012439.1 |
217142 |
DR diag-level is not synced with domain boot parameters diag-level |
2010-07-06
|
1011923.1 |
216320 |
Disabling Capacity On Demand (COD) on Sun Fire[TM] (3800-6800) |
2009-12-22
|
1011922.1 |
216319 |
Sun Fire[TM] (3800-6800): prtdiag reports Incorrect status on power supplies |
2009-12-22
|
1011882.1 |
216268 |
Sun Fire[TM] 3800-6800: Usage: error from using DR (cfgadm) |
2010-06-15
|
1010924.1 |
215073 |
Sun Fire[TM] Server : Dynamic Reconfiguration (DR) fails due to Real Time (RT) process running. |
2011-01-30
|
1010922.1 |
215069 |
New US IV board were just added and the OS will not see them properly |
2010-05-27
|
1010901.1 |
215041 |
Installation of Solaris[TM] 9 04/04 or Solaris[TM] 10 causes domain to panic or ERROR Fast Data Access MMU Miss |
2010-07-06
|
1010378.1 |
214238 |
Sun Fire[TM] 3800/4800/4810/6800/E4900/E6900: Moving system boards from one segment to another |
2010-05-21
|
1010310.1 |
214143 |
Telnet send break fails to enter domain shell on Sun Fire[TM] system controller |
2008-12-28
|
1009954.1 |
213638 |
Sun Fire[TM] Midrange Server: Time Jumps When SC Accumulates Extended Uptime |
2010-07-06
|
1009696.1 |
213337 |
"kstat -p" and "prtdiag -v" may give seemingly different PCI bus speeds for Dual Fast Ethernet and Dual SCSI PCI Adapters |
2010-07-06
|
1009648.1 |
213283 |
SepromContainer.writeOut: sun.serengeti.I2cException: verify error: |
2010-07-06
|
1009467.1 |
213078 |
How to clear faults in FMA after component replacement on Sun Fire[TM] servers. |
2011-06-07
|
1009358.1 |
212945 |
Pending "disabled" status being reported by "showcomponent" command |
2010-07-07
|
1009332.1 |
212913 |
Certain Memory Configurations with 5.19.0 and 5.19.1 May panic on boot with init level POST |
2010-07-07
|
1009228.1 |
212768 |
Sun Fire[TM] Serengeti Server: System Serial Number(SSN) in showplatform different from SSN on the label. |
2010-06-14
|
1009206.1 |
212741 |
How to remove unwanted aliases in NVRAM; nvunalias does not remove them from NVRAM, still show when run "devalias" |
2009-11-29
|
1009178.1 |
212708 |
Sun Fire[TM] 6800 domain's Notice messages: "platmod: [ID 349959 kern.info] NOTICE: enque_ecc_mailbox_msg: sbbc_mbox_queue_ecc_event not found" |
2010-07-07
|
1009008.1 |
212426 |
Sun Fire[TM] 3800, 4800, 4810, 6800, E4900, E6900, V1280, E2900, Netra 1280, or 1290 server: NCPQ_TO workarounds |
2010-07-15
|
1008995.1 |
212411 |
How to recover a domain on Sun Fire[TM] 3800/4800/4810/4900/6800/6900 Midrange Server that is found in Standby mode. |
2009-03-09
|
1008844.1 |
212179 |
Sun Management Center "chassis failed to update status" errors on Sun Fire[TM] v1280, E2900, 3800, 4800, 4810, E4900, 6800, E6900, and Netra[TM] 1280/1290 servers. |
2009-11-05
|
1008719.1 |
211973 |
Resolving Hardhang problems on Ultra Servers |
2011-04-21
|
1008672.1 |
211889 |
Sun Fire[TM] (3800-6800/E2900-E6900/v1280) Server: System Controller Setdate to Daylight Savings Time |
2010-07-06
|
1007933.1 |
210942 |
Dynamic Reconfiguration (DR) failure on Sun Fire[tm] 4800 running Oracle |
2009-02-17
|
1007782.1 |
210767 |
Dynamic Reconfiguration or hot plug problems on a QGE HBA (4444A). |
2010-05-27
|
1007736.1 |
210714 |
Diagnosing multiple DIMM CE errors occurring on multiple DIMMs |
2010-12-28
|
1007666.1 |
210616 |
Sun Fire[TM] Servers/Solaris[TM] Operating System: CD-ROM Boot Attempt Fails With Error: "Cannot Assemble Drivers for Root" |
2010-08-27
|
1007552.1 |
210451 |
Sun Fire[TM] 3800-6800: Upgrade to firmware 5.13.x causes loss of network settings on the SC |
2009-09-27
|
1007102.1 |
209793 |
How to reset the OpenBootProm Password on Sun Fire 3x00-6x00[TM] server |
2010-05-27
|
1006864.1 |
209529 |
Sun Fire[TM] Mid Range and High end servers: Dynamic Reconfiguration for Uniboard removal may cause Lotus Domino server instance(s) to abnormally stop |
2010-05-26
|
1006508.1 |
209106 |
Sun Fire[TM] V1280/E2900/3800/48x0/E4900/6800/E6900: Prtdiag and showboard display wrong cpu speed. |
2010-07-06
|
1006156.1 |
208621 |
"ERROR: Can't open boot device" booting CDROM or disk with Sun[TM] Dual FastEthernet / Dual SCSI PCI Card |
2010-07-06
|
1005826.1 |
208090 |
Solaris[TM] won't boot off of any device on a Sun Fire[TM] (3800-6800) |
2009-09-20
|
1005825.1 |
208088 |
Sun Fire[TM] (3800-6800): Anomalies in showboards power status |
2009-09-27
|
1005013.1 |
207032 |
probe-scsi-all may fail without reset-all on all Sun[TM] Systems |
2010-07-06
|
1004794.1 |
206653 |
Sun Fire[TM] 3800-6800 servers with Emulex lpfc version 4.21e might panic upon cold boot |
2009-12-03
|
1004782.1 |
206640 |
probe-scsi-all can see disks, but boot -r, devfsadm , and drvconfig, fail to add disks to OS |
2011-05-27
|
1004680.1 |
206486 |
Sensor status warning messages on Sun Fire[TM] (3800-6800)systems |
2009-12-22
|
1004679.1 |
206485 |
Sun Fire[TM] Servers: setdefaults does not reset local-mac-address? parameter |
2010-10-18
|
1004364.1 |
206035 |
Sun Fire[TM] Midrange Server: Safari Port Error may be caused by a resetting SC |
2011-04-27
|
1004236.1 |
205860 |
Unconfigured domains report "current year is 197x" after a reboot of the SC in 2007 |
2008-07-29
|
1004235.1 |
205859 |
Frame Manager "Service LED" is on but no failures are reported by the system |
2011-03-30
|
1003251.1 |
204467 |
Obtaining part and serial numbers from Sun Fire[TM] (3800-6800) system board |
2009-03-01
|
1003105.1 |
204251 |
Sun Fire[TM] (3800-6800) FTP login failure while doing flashupdate on a System Controller |
2010-06-16
|
1002417.1 |
203384 |
Missing drv/clone forceload in /etc/system on a system with Emulex cards may cause panic during boot |
2010-06-07
|
1002133.1 |
203034 |
Sun Fire[TM] Midrange Servers: Fast Data Access MMU Miss when issuing probe-scsi-all or boot |
2010-07-06
|
1002033.1 |
202844 |
Sun Fire[TM] v1280, E2900, 3800, 4800, 4810, 6800, E4900, E6900, and Netra 1280, 1290 Server: How to Recover from a Hung System Controller |
2010-09-16
|
1001689.1 |
202295 |
Sun Fire[TM] Connection refused, console busy |
2009-09-20
|