Solution Type Problem Resolution Sure Solution 1009648.1 : SepromContainer.writeOut: sun.serengeti.I2cException: verify error:
PreviouslyPublishedAs 213283 Symptoms SepromContainer.writeOut: verify error message are logged by the system controller. Typical messages: Example 1 Apr 1 13:33:37 ospprod2 lw8: [ID 575994 kern.error] /N0/SB0/P2/B1/D1: SepromContainer.writeOut: Example 2 May 17 08:07:16 kgebzdb_sc0 Platform.SC: [ID 921792 local0.error] SepromContainer.writeOut: verify Example 3 Jun 01 10:10:14 sf6800-1sc0 Platform.SC: [ID 266093 local0.warning] /N0/SB0/P3/B1/D3: These messages may appear once, a few times, or at regular (4 hours FRU update cycle) intervals. Resolution Suggested course of action Background Information on the Errors SEEPROMs hold information such as Part Number, Serial Nunmber, power events, etc for various components in the system. Components like DIMMS, SB, IO, PS etc have SEEPROMs. Part of the SEEPROM is fixed, part is dynamic and sometimes modified by ScApp. In the above example 1, SCAPP wants to write information into DIMM /N0/SB0/P2/B1/D1 's SEEPROM via the I2c bus. Upon verification of that write, SCAPP discovers a mismatch.The SepromContainer.writeOut verify error does not affect Solaris[TM] Operating System Domains at all and is essentially harmless because the error is taking place in an area (SEEPROM) that Solaris does not utilize. Suggested Action Plan In most cases, the problem can be ignored because the error is not in a region that will cause a domain outage. The biggest issue with this error is whether or not the messages themselves are excessive or not.
In example 3 above, the logical error in the seeprom segments were repaired. The errors were caused by an abrupt power loss, as might happen if the Frame Manager keyswitch were turned off while one or more domain setkeyswitch on operations were underway. A number of seeprom segments were half written when the power was lost. At recent FW levels, in this case 5.19.5, the ScApp methods that write the records will quietly clean these incomplete records up as it discovers them.
Relief/Workaround Additional Information In cases where several FRUs are reported, then the problem might be the I2C bus itself. The I2C bus runs from the system controller(s) to all FRU holding SEEPROMs. Example:
In cases where a section of the I2C bus is bad, other errors like I2C timeouts (I2cComm.busyWait) might be reported. The faulty FRU must then be located by finding where in the tree the problem starts. In this case contact sun support services to help determine the source of the fault. Product Sun Fire V1280 Server Sun Fire E6900 Server Sun Fire E4900 Server Sun Fire E2900 Server Sun Fire 6800 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Sun Netra 1290 Server Netra 1280 Server Internal Comments Try to persuade customers not to ask for replacement. Examples for the the situation described in the "Additional Information" section, can be found here: <Document: 1005071.1> . SepromContainer.writeOut, verify error, seprom, seeprom, DIMM, PS, I2cException Previously Published As 85226 Attachments This solution has no attachment |
||||||||||||
|