Solution Type Problem Resolution Sure Solution 1005013.1 : probe-scsi-all may fail without reset-all on all Sun[TM] Systems
PreviouslyPublishedAs 207032 Symptoms 'probe-scsi-all' may fail with the following error message (or similar). {0} ok probe-scsi-all This command may hang the system if a Stop-A or halt command has been executed. Please type reset-all to reset the system before executing this command. Do you wish to continue? (y/n) y /pci@1f,700000/scsi@2,1 ERROR: LSI1030: timeout waiting for interrupt status. ERROR: LSI1030: Could not set initiator ID. ERROR: LSI1030: timeout waiting for interrupt status. ERROR: LSI1030: Could not set initiator ID. Can't open SCSI host adapter /pci@1f,700000/scsi@2 ERROR: LSI1030 MPT Firmware, Fault code: 8112: PCI bus fault ERROR: LSI1030: Could not set initiator ID. ERROR: LSI1030 MPT Firmware, Fault code: 8112: PCI bus fault ERROR: LSI1030: Could not set initiator ID. Can't open SCSI host adapter {0} ok Resolution Run 'reset-all' prior to run 'probe-scsi-all': ok reset-all ok probe-scsi-all Important Notes: If performing this recommendation when troubleshooting a problem at OBP, verify the auto-boot? parameter is set to false. Product Sun Fire V440 Server Sun Netra 1290 Server Netra 1280 Server Sun Fire V1280 Server Sun Fire V880/890 Sun Fire E6900 Server Sun Fire E4900 Server Sun Fire E2900 Server Sun Fire 6800 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Internal Comments See the following info also:
probe-scsi-all, reset-all, boot, auto-boot? Previously Published As 76093 Change History Date: 2007-01-29 User Name: 31620 Action: Approved Comment: Verified Metadata - ok Verified Keywords - ok Verified still correct for audience - currently set to contract Audience left at contract as per FvF at http://kmo.central/howto/content/voyager-contributor-standards.html Checked review date - currently set to 2008-01-26 Checked for TM - ok as presented Activated STM links on both links in internal only section Attachments This solution has no attachment |
||||||||||||
|