Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1018210.1 : Sun Fire[TM] Midframe Server:Symptom:Flashupdate fails when user is root-No boards can be updated
PreviouslyPublishedAs 229578 Symptoms Attempt to flashupdate the System Controller fails to upgrade firmware and simply resets the System Controller when root is used as the FTP user account. SC> flashupdate -f ftp://root:password@hostname//tmp/directory scapp rtos As part of this update, the system controller will automatically reboot. RTOS will be upgraded automatically during the next boot. ScApp will be upgraded automatically during the next boot. Do you want to continue? yes (-y) No boards can be updated. Rebooting the SC to automatically complete the upgrade. Rebooting. Software Reset... Resolution The ftp source is failing to be seen. Make sure root is either present or uncommented in the /etc/ftp/users file. Make sure that the firmware is actually at the location specified in the URL. Product Sun Fire 6800 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Internal Comments This document is a Normalized Resolution Path and is managed by the MidRange Server Group's Domain Engineer. * Please send any feedback on this resolution path to [email protected]. Include the document ID in the subject line. * Do not update this document without first contacting the feedback email alias. system, controller, ftp, firmware, SC, normalized Previously Published As 74108 Attachments This solution has no attachment |
||||||||||||
|