Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1004679.1
Update Date:2010-10-18
Keywords:

Solution Type  Problem Resolution Sure

Solution  1004679.1 :   Sun Fire[TM] Servers: setdefaults does not reset local-mac-address? parameter  


Related Items
  • Sun Fire 4810 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Netra 1280 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
206485


Applies to:

Sun Fire 3800 Server
Sun Fire 4800 Server
Sun Fire 6800 Server
Sun Fire E2900 Server - Version: Not Applicable and later    [Release: NA and later]
Sun Fire 4810 Server - Version: Not Applicable and later    [Release: NA and later]
All Platforms

Symptoms

The Sun Fire[TM] System Controller setdefaults command does not do anything with the local-mac-address OBP variable.

Cause

There is no "Cause", this is expected behavior.

Solution

System Controller Application (ScApp) does not store any OBP parameters initially. When a property is changed, OBP asks ScApp to save this information. ScApp treats the data as opaque and does not interpret it in any way. When OBP starts, it asks ScApp for a list of arbitrary properties. If a property is returned, OBP uses it. Otherwise OBP just uses a hardcoded default value.

In other words, the ScApp setdefaults command does not know the names of any OBP properties which are private to OBP.  Since ScApp doesn't know the properties, it cannot set them to default values.