Solution Type  Problem Resolution Sure

Solution  1008995.1 :   How to recover a domain on Sun Fire[TM] 3800/4800/4810/4900/6800/6900 Midrange Server that is found in Standby mode.  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire 4810 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
212411


Symptoms
A domain on a Sun Fire[TM] 3800/4800/4810/4900/6800/6900
Midrange Server is found in Standby mode.

Resolution
If the domain was active prior to being in a Standby mode without user
intervention, then a setkey off followed by a setkey on sequence will
properly recover the domain. This will ensure that the domain resources
will be in a known state.
With the following data it may be possible to determine if this event
occurred due to a power failure or environmental issue:
- domain loghost data
- domain console output
- domain showlogs output
- platform loghost data
- platform console output
- platform showlogs output


Additional Information
See the following documentation on setkey and Standby mode:
Sun Fire[TM] Midrange System Controller Command Reference Manual
Sun Fire[TM] Midrange Systems Platform Administration Manual
Part Numbers will vary depending on Firmware levels.


Product
Sun Fire 6800 Server
Sun Fire 4810 Server
Sun Fire 4800 Server
Sun Fire 3800 Server
Sun Fire E4900 Server
Sun Fire E6900 Server

found, Standby, domain, recover
Previously Published As
71386

Change History
Date: 2006-03-07
User Name: 71396
Action: Approved
Comment: Publishing.
Version: 3
Date: 2006-03-07
User Name: 71396
Action: Accept
Comment:
Version: 0
Date: 2006-03-07
User Name: 77482
Action: Approved
Comment: Made couple minor changes. Doc is ready to be Published
Version: 0
Date: 2006-03-03
User Name: 114416
Action: Approved
Comment: clarified the setkey sequence and added Amazon to doc
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback