Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1009178.1 : Sun Fire[TM] 6800 domain's Notice messages: "platmod: [ID 349959 kern.info] NOTICE: enque_ecc_mailbox_msg: sbbc_mbox_queue_ecc_event not found"
PreviouslyPublishedAs 212708 Symptoms Notice messages in domain log file: "platmod: [ID 349959 kern.info] NOTICE: enque_ecc_mailbox_msg: sbbc_mbox_queue_ecc_event not found" Resolution Sun Fire[TM] 6800 domain's Notice messages: Above is resolved with Patch ID: 110373-05 or higher - fixed Bug ID: 4860142. According to Bug ID: 4860142, the notice messages in the system log file are likely the result of applying S8 KJP Patch ID:108528-24 or newer and not applying S8 sgsbbc driver Patch ID: 110373-05 or newer. (Theoretically, this could also occur if the sgsbbc driver were not loaded, but in the practical sense we would not then have a running Serengeti.) The fix for Bug ID: 4860142 was splitted by the S8 patch gate keepers into these two patches. This created a soft one-way dependency. Patching the platmod with Patch ID: 108528-24 or newer but not patching the sgsbbc driver with Patch ID: 110373-05 or newer violates this dependency and prevents any ECC events from being reported to the SC. This was documented in the README file for the S8 Kernel Update: NOTE 48: To get the complete fix for Bug ID: 4860142, or the complete fix for Bug ID: 4833032 on Serengeti, please also install the following patch: 110373-05 (or newer) sgsbbc patch If Patch ID: 110373-05 or newer is applied, the dependency should be fixed. Incidentally, this patch does affect Solaris[TM] 8 CPU and Memory offlining mechanism if missing. As part of CHS data mechanism, any missing patch 110373-05 is definitely responsible for the failure of the domain OS to communicate any ECC action to the SC. On a Serengeti, Solaris[TM] is completely dependent on the sgsbbc driver to communicate information about ECC events to the SC (eg. for purpose of CHS data). Hence, also for Solaris CPU and Memory offlining to work, the requirements are Solaris 8 OE update 4 with KU-108528-29 plus Patch ID: 117000-03 (or higher) and Patch ID: 110373-05 (or higher). Note: Patch ID: 110373-05 (or higher) is not found currently in Solaris 8 Recommended Patch Cluster. Product Sun Fire V1280 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Sun Fire 6800 Server Internal Comments For the internal use of Sun Employee's. References: - Bug ID: 4860142 - Compiled technical contributions from [email protected] (Bug 4860142). platmod, enque_ecc_mailbox_msg: sbbc_mbox_queue_ecc_event not found, sgsbbc, chs, serengeti, lw8, 3800, 4800, 4810, 6800, 1280, V1280, SC Previously Published As 79220 Change History Bug ID: 4833032 is found in the Resolution Statement as an internal document. We can do the following in order to be able to publish this document. 1). Move the ID to the internal comments. 2). Remove the reference to the ID 3). Replace the current ID with another that relates. Date: 2005-01-24 User Name: 111868 Action: Approved Comment: Verified Metadata Verified audience Checked review date Checked for TM removed the name as per Josh request Publishing Version: 3 Date: 2005-01-24 User Name: 111868 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|