Solution Type Problem Resolution Sure Solution 1005825.1 : Sun Fire[TM] (3800-6800): Anomalies in showboards power status
PreviouslyPublishedAs 208088 Symptoms After removing a power supply or fan tray, the results of the showboards command shows that the power is still ON. Also, poweron/poweroff are confused in this situation, that is, poweron still thinks the component is still ON. Resolution This is a bug documented in bugid 4448419. The current workaround is to reboot the System Controller. Product Sun Fire 6800 Server Sun Fire 3800 Server Sun Fire 4800 Server Internal Comments Authors: Rick Holmes/John Cecere Previously Published As 26872 Change History Date: 2006-01-19 User Name: 31620 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT Version: 0 Date: 2006-01-19 User Name: 31620 Action: Update Started Comment: SSH AUDIT Version: 0 Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : George Bolduc comment : Added (3800-6800) to the title. date : Aug 14, 2001 updated by : George Bolduc comment : Article created. date : May 10, 2001 updated by : George Bolduc comment : Transferred from the Control Center's website. date : May 10, 2001 updated by : George Bolduc comment : Transferred from the Control Center's website. date : May 10, 2001 Version: 0 Product_uuid 29da7938-0a18-11d6-8a41-9ed1ad6d6779|Sun Fire 6800 Server 29d05214-0a18-11d6-92b2-a111614865b5|Sun Fire 3800 Server 29d3a694-0a18-11d6-92da-df959df44cdd|Sun Fire 4800 Server Attachments This solution has no attachment |
||||||||||||
|