Solution Type Problem Resolution Sure Solution 1012439.1 : DR diag-level is not synced with domain boot parameters diag-level
PreviouslyPublishedAs 217142 Symptoms The current diagnostic levels for cfgadm DR are "init, quick, min, default, mem1, mem2". The choices for diag-level settings from the Domain Boot Parameters specified in the setupdomain command are "init, quick, max, default, mem1, mem2". There is no "max" setting from the cfgadm command. Resolution This bug was generated not from customer complaint but internal sources. Therefore the limited resources of the firmware group will not be spent to resolve this minor problem at this time. Therefore, any one performing a DR operation needs to be aware that the DR diag-level specified from Solaris[TM] does not include the "max" parameter. Since the "default" parameter is essentially the same as "max" there is no loss of functionality. This Bug has been fixed in 5.19.0 FW revision (<SUNPATCH: 114526-01>) Relief/Workaround Additional Information Notice current valid diagnostic levels for DR cfgadm are "init, quick, min, default, mem1, mem2", but valid diag-level settings for Domain Boot Parameters from setupdomain are "init, quick, max, default, mem1, mem2": sc0:A> setupdomain Domain Boot Parameters
---------------------- DR in default mode, runs the quickest test available, unless specified in the cfgadm command. Product Sun Fire V1280 Server Sun Fire E6900 Server Sun Fire E4900 Server Sun Fire E2900 Server Sun Fire 6800 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Internal Comments For internal use only. Audited/updated 11/24/09 - [email protected], Mid-Range Server Content TeamBug ID: 4498429 dynamic reconfiguration, diag-level Previously Published As 79255 Change History Date: 2004-12-17 User Name: 71396 Action: Approved Comment: Reviewed document, publishing. Version: 5 Date: 2004-12-15 User Name: 71396 Action: Accept Comment: Version: 0 Product_uuid 6a74b2f9-bbd8-4b2c-870d-b6b73d6e224f|Sun Fire V1280 Server 4fe39727-0599-11d8-84cb-080020a9ed93|Sun Fire E6900 Server bed24aa9-0598-11d8-84cb-080020a9ed93|Sun Fire E4900 Server 63ff680d-0598-11d8-84cb-080020a9ed93|Sun Fire E2900 Server 29da7938-0a18-11d6-8a41-9ed1ad6d6779|Sun Fire 6800 Server 29d6f808-0a18-11d6-8aa8-943929fbbdd8|Sun Fire 4810 Server 29d3a694-0a18-11d6-92da-df959df44cdd|Sun Fire 4800 Server 29d05214-0a18-11d6-92b2-a111614865b5|Sun Fire 3800 Server Attachments This solution has no attachment |
||||||||||||
|