Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge 3510 FC Array, RoHS:YL : How Tos


How Tos Former IBIS ID Synopsis Last Modified Date
1272612.1 How to Remove and Replace a Sun Storage 3510/3511 FC Array Battery:ATR:1009:0 [Video] 2011-05-05
1021453.1 271929 How to avoid the probe-scsi-all command hanging the system when there are multiple hosts on the same Fibre Channel Loop 2010-01-25
1019030.1 233501 Sun Storage 3120, 33x0 SCSI and 351x FC Arrays: Support for mixed Spindle Speeds (RPMs) in arrays and expansion units 2010-11-15
1018906.1 230750 Sun StorEdge[TM] 3510 FC Array and Sun StorEdge[TM] 3511 SATA Array: Replacing the I/O Controller Module 2011-02-07
1018772.1 230503 Sun Storage 3310, 3320, 3510, & 3511: Setting Passwords on the SE3310, SE3320, SE3510 & SE3511 Arrays 2010-08-02
1018716.1 230430 How to Unconfigure a Single Lun from a Target which has multiple Luns 2011-06-08
1018173.1 229526 Drives may be marked BAD upon upgrade to 4.13 firmware which may be good drives. 2009-02-12
1017944.1 229213 Sun StorEdge[TM] 3510 - What is the "Remote Redundant Controller" setting for? 2009-09-22
1017748.1 228960 How to Set the Date of Sun Storage[TM] 351x Array Batteries After Replacement 2010-11-30
1017719.1 228928 Sun StorEdge[TM] 351x/33x0: Telnet session problems with 3.2x Controller Firmware 2009-12-06
1017707.1 228912 Logical Unit Number(LUN) 0 , A SCSI Requirement 2009-12-03
1012994.1 217792 Sun StorEdge[TM] 3510 FC Array: SCCLI loop references - SES view from loop A 2009-12-04
1012828.1 217609 Sun Storage[TM] 3510 FC Array Experiences Unexpected SES Events 2010-12-21
1012786.1 217562 Sun StorEdge[TM] 351x FC Array: Unable to set scsi-3 persistent reservations 2009-01-20
1012660.1 217413 Can't Connect to Sun StorEdge[TM] Array via Ethernet 2011-02-13
1012557.1 217290 Sun StorEdge[TM] 3510/3511 Arrays: Understanding Link Error Status Block (LESB) counters. 2010-09-30
1012343.1 217029 How to Collect Support Information for Sun Storage 33xx/35xx Arrays 2010-11-29
1012254.1 216903 Sun StorEdge[TM] 3000: Saving and Restoring NVRAM and Logical Drive Configuration 2009-09-20
1012024.1 216477 How To Resolve Sun StorEdge[TM] 351x Array: SES or PLD Firmware Mismatches 2011-05-13
1011735.1 216092 How to Add New Storage Disk Devices to Solaris[TM] Without Performing a Reconfiguration Boot 2011-05-30
1011431.1 215672 Troubleshooting Sun StorEdge[TM] 33x0/351x Hardware 2011-05-16
1011302.1 215508 Verify DMP Health 2010-01-20
1010987.1 215145 Oracle Explorer Data Collector: How to Get se3kxtr in Out-of-Band Status 2011-05-06
1010848.1 214983 Sun Storage[TM] Array Battery Life Cycle 2011-03-16
1010810.1 214938 How to resolve "DRAM parity error detected" on Sun Storage 33x0/351x Arrays 2010-07-06
1010657.1 214710 The Proper Way to De-stage Cache in a Sun StorEdge[TM] 351x/33x0 Array is to Use the "shutdown" Command 2009-12-27
1010599.1 214582 Sun StorEdge[TM] 3510/3511 FC Array: Scgdevs cluster command may cause SE3510 arrays to reset. 2009-01-05
1010511.1 214437 Sun[TM] StorageTek 3000 Array: Resetting Factory Defaults 2009-11-08
1010064.1 213814 Sun StorEdge[TM] 33x0/351x Array - How to Replace a Hard Drive 2011-05-16
1009885.1 213556 Sun StorageTek[TM] 3510FC midplane temperature report higher values after upgrade of ses to 1102 2009-09-15
1009716.1 213359 Sun StorEdge [TM] 33x0/351x: Steps to Verify Configuration Parameter Settings 2011-03-07
1009274.1 212837 Sun StorEdge[TM] 3510 FC Array: Understanding The Internal Loop Architecture During Controller Failover 2011-05-13
1009268.1 212828 How to replace and assign the new drive in the same location as the failed disk in a raid1 logical drive in Sun StorEdge[TM] 3000 ? 2009-12-05
1009253.1 212803 Sun StorEdge[TM] 3510/3511 FC Array: StorADE 2.4 Quick Installation and Configuration Guide. 2011-04-17
1009196.1 212731 Sun StorEdge[TM] 3510: How to Map Partitions to Multiple Hosts in a SAN Using Host Filters 2011-02-07
1009168.1 212696 Sun StorEdge[TM] 33x0/351x Host Channel Port IDs 2010-01-27
1009069.1 212505 Sun StorEdge[TM] 351x Array: Battery Expiration and Status Monitoring 2010-06-30
1008932.1 212292 Deletion or modification of a partition on the Sun StorEdge[TM] 33x0 SCSI and Sun StorEdge 3510 FC & 3511SATA arrays with FW 4.x. 2009-01-11
1008255.1 211315 Sun StorEdge[TM] 351x Arrays: How to Handle "Drive Recovered Error Reported" and Other Disk Drive Messages 2011-06-06
1008236.1 211296 New LUN mapped on Sun StorageTek[TM] 351x Array not seen in format 2010-01-12
1008196.1 211255 Recreate lun mapping from show configuration on a Sun StorEdge[TM]3000 array 2009-05-27
1007692.1 210659 Sun Storage 351x Array switch settings and disk IDs 2010-07-01
1006955.1 209625 Sun Storage[TM] 3000 Arrays: Cheatsheet for Documentation References Before Replacing an I/O Controller 2010-12-09
1006856.1 209520 Troubleshooting StorEdge [TM] 351x Redundant Loop Failures 2010-01-20
1006608.1 209218 Microsoft Windows(R) operating system: How to obtain troubleshooting information for storage issues 2009-12-20
1006605.1 209214 Sun StorEdge[TM] 3510/3511 Arrays: Definitions of the Logical Drive Firmware Menu 2008-12-30
1006471.1 209066 Mapping Solaris[TM] host disk devices to Sun StorEdge[TM] 351x Fibre Channel Array LUN's 2010-06-01
1006414.1 208997 Sun StorEdge[TM] 351x/33x0 Arrays: Mute Button held during reset of array will cause false battery failure messages 2009-11-08
1006405.1 208987 Quickstart Reference for Sun Storage disk replacement 2011-06-01
1005598.1 207771 How to partition a logical drive on a Sun StorageTek[TM] 3310, 3320, 3510 or 3511 array [Video] 2010-10-01
1005597.1 207769 How do I configure a local/global spare on a Sun Storage 3310, 3320, 3510 or 3511 Array? [Video] 2010-10-11
1005475.1 207599 What is the meaning of the message: from the Solaris [TM] format(1m) utility? 2011-05-13
1005062.1 207118 How to use the sccli command to configure and unconfigure Global Spare Disks in Sun Storage 3310, 3320, 3510, and 3511 Arrays 2010-06-28
1005034.1 207084 Understanding the "show loop-map" output for the Sun StorEdge[TM] 3510 2009-03-03
1004772.1 206624 Sun StorEdge[TM] 3510 FC Array/Sun StorEdge[TM] 3310:Symptom:Firmware version shown in label on 'format' output is out of date 2009-11-08
1004759.1 206608 Sun StorEdge[TM] 3000:Tech Tip:Access out of band (network) 2009-11-10
1004741.1 206583 Sun StorEdge[TM] 3310/3320/3510/3511 and VxVM - How to Setup VxVM DMP to Work on These Arrays 2008-06-01
1004355.1 206020 How do I create a logical drive on a Sun StorageTek[TM] 3310,3320,3510 or 3511 array? [Video] 2010-10-04
1004352.1 206015 How to Download and Install Sun Storage[TM] Configuration Service Software (SUNWsscs) 2011-05-12
1003908.1 205483 Sun Storage 3310/3320/3510/3511: SSE or FE steps to follow to assist with RCA. 2010-08-02
1003872.1 205436 Sun StorEdge[TM] 3510 with non-default RCCom channels will require downtime for controller replacement. 2009-09-21
1003692.1 205207 Sun StorEdge[TM] 3310/3320/3510/3511: How To Replace A Failed Disk In A Logical Drive 2011-05-12
1003631.1 205125 Implications of Predictable Failure Test on Sun StorEdge[TM] 3000 Family with Firmware 4.11 2009-08-06
1003605.1 205093 StorEdge [TM] 3310, 3320, 3510, 3511: Failed Component Beep Codes 2009-12-27
1003584.1 205059 Sun StorEdge[TM] 3000 Series Arrays: How to Reset the Minnow to Factory Default Settings or Saved Settings to the Disks. 2011-05-27
1003561.1 205011 Sun StorEdge[TM] 33x0 and 351x: Host Channel LUN Assignments 2009-12-27
1003544.1 204985 How to Capture Console Output in a Microsoft Windows(TM) HyperTerminal Session 2009-07-19
1003542.1 204978 How to setup SSCS monitoring of Sun StorEdge[TM] 3000 family storage arrays 2009-12-27
1003527.1 204959 Sun StorEdge[TM] 351x/33x0 Arrays: Examples of sccli commands to create/map LDs and partitions 2009-12-04
1003370.1 204691 Sun StorEdge[TM] 3510:Tech Tip: Fail-over Functionality Testing 2009-01-25
1002906.1 204001 How to create or change primary and secondary IDs on a StorEdge(TM) 33x0 and 351x Array [Video] 2010-10-05
1002758.1 203773 Sun StorEdge[TM] 351x: JBOD's at Different SES Firmware Revisions is not reported 2009-04-12
1002465.1 203438 Verifying STMS (mpxio) Health 2009-10-08
1002442.1 203415 Setting the time on a Sun StorEdge [TM] 3510 FC Array 2009-02-26
1002426.1 203394 Battery replacement procedure for the Sun StorEdge[TM] 3310SCSI/3510FC/3511FC Arrays 2009-12-27
1002402.1 203363 Sun StorEdge[TM] 33x0/3510/3511: What does the "M" mean in the show disks output 2010-01-14
1002298.1 203225 Best Practices: configuring target id's on Sun StorEdge[TM] 3xx0 arrays 2011-04-06
1002266.1 203191 How to convert a Sun StorEdge[TM] 33x0/351x single controller array to a dual controller array 2009-11-12
1002198.1 203110 Reserved ip address range for Sun StorEdge [TM] 3510 FC Array 2009-09-13
1002130.1 203031 Sun StorEdge[TM] 33x0/351x: How to reset "disk Reserved space" on a disk drive 2009-12-30
1001903.1 202639 How to configure Sun Storage 3310/3510/3511/3320 Arrays for event reporting WITHOUT using the sscs GUI. 2010-08-02
1001838.1 202515 Sun StorEdge[TM]3510 FC Array voltage sensor information. 2011-02-07
1001837.1 202514 How to Replace a Disk in a Sun Storage[TM] 3510 FC JBOD Array 2011-02-11
1001781.1 202434 Sun StorEdge[TM] A5x00, T3, 6120, 33xx, 351xFC, A3500FC arrays: Disk Firmware/Patch Matrix Summary Rev. 3.23 2011-05-27
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback