Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1006608.1 : Microsoft Windows(R) operating system: How to obtain troubleshooting information for storage issues
PreviouslyPublishedAs 209218 Description This article contains basic troubleshooting data for Microsoft Windows operating systems for storage related issues A growing number of Sun StorEdge? products have been certified, qualified and supported for Microsoft Windows? operating systems. This article should enable you to obtain basic troubleshooting data for Microsoft Windows? operating systems for storage related issues. For more generic issues you should reference troubleshooting doc. <Document: 1010936.1> Microsoft Windows and Linux operating systems: How to obtain troubleshooting information: The following Microsoft Windows? operating systems will be covered:
Steps to Follow Data Collection Steps Basic Microsoft Windows Data
CollectionFor most storage and storage software
related issues, the basic data to collect
are:
Veritas Storage Foundation Data CollectionFor further information go to http://support.veritas.com/ . The following commands use the CLI feature, and redirect to an output file:
Now there should be a command prompt on the screen.
Redirecting stdout to a file
If Veritas DMP has been licenced, additional commands follow:
Host Bus Adapter - Fibre ChannelFor a Windows platform, it should be able to collect the data
via screenshots, QLogicFor further information go to http://www.qlogic.com/Support/default.aspx . We will use CLI feature and redirect to an output file for following commands:
Now you should have a command prompt on the screen.
Please notice you require to install the SANsurfer FC HBA CLI application before. EmulexFor further information, go to: http://www.emulex.com/ts/ We will use CLI feature and redirect to an output file for following commands.
Now you should have a command prompt on the screen. Redirecting stdout to a file is Unix style .
Please notice you require to install the HBAnyware Command-Line Interface before. Sun Storedge Traffic Manager SSTMFor further information go to http://www.sun.com/products-n-solutions/hardware/docs/Software/Storage_Software/Sun_StorEdge_Traffic_Manager/ We will use CLI feature and redirect to an output file for following commands.
Now you should have a command prompt on the screen. Redirecting stdout to a file is Unix style .
HiCommand? Dynamic Link Manager HDLMFor further information refer to HiCommand? Dynamic Link Manager HDLM User`s Guide. We will use the DLMgetras utility for data collection. Since HDLM error information will be cleared soon the system restarts please run DLMgetras priory a system restart.
Now you should have a command prompt on the screen.
Please use an empty folder as output directory. RDAC and MPIO DSM for 6000 and 2500 ArraysDownload a copy of WinObj from Microsoft:
Device->csmdsm->array_name->Controller A and Controller B(expand BOTH paths) Drive:\Program Files\DSMDrivers\csmdsm\dsmUtil.exe -P GetMpioParameters >> hostname_dsm_param.txt Product Sun StorageTek 9990 System Sun StorageTek 9980 System Sun StorageTek 9970 System Sun StorageTek 9960 System Sun StorageTek 9910 Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the “Document Feedback” alias(es) listed below: [email protected] References to understand Microsoft Storage TechnologiesWith most recent releases of Microsoft Windows 2003 and Microsoft Windows XP two major changes had been introduced - Microsoft Multipath I/O (MPIO) and Storport Driver Model. Microsoft Multipath I/O (MPIO)The Microsoft Multipath I/O (MPIO) driver development kit allows storage vendors to build interoperable multipath solutions that integrate tightly with the Microsoft Windows family of products. If the configuration meets the prerequisites this will be a builtin feature for Microsoft Windows operating systems.
Storport Driver ModelStorport is a new storage driver model created by Microsoft for Windows Server 2003 and future Windows operating systems. Storport offers a higher performance architecture and better Fibre Channel compatibility in Windows systems. Try out following URLs as references.
Fibre Channel Information Tool (fcinfo)Works on Microsoft Windows Server 2003 and Microsoft Windows 2000 systems
Hitachi Dynamic Link ManagerMicrosoft Windows HDLM Data Collection (DLMgetras)ID: hds22525 SSTM, Veritas, QLogic, Emulex, multiplatform, windows, storedge, storage foundation, system information, xp, HDLM, troubleshoot, normalized, RDAC, MPP, mpp, rdac, DSM, MPIO Previously Published As 81805 Change History Date: 2007-08-21 User Name: 7058 Action: Approved Comment: OK to publish. Only normalized keyword added. Version: 15 Date: 2007-08-21 User Name: 88109 Action: Approved Comment: added normalized keyword Version: 0 Attachments This solution has no attachment |
||||||||||||
|