Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1003561.1 : Sun StorEdge[TM] 33x0 and 351x: Host Channel LUN Assignments
PreviouslyPublishedAs 205011 Description This document outlines the number of LUNs that can be designated on the Sun StorEdge[TM] 3310, 3320, 3511, and 3510 arrays under different configurations. Steps to Follow Host Channel LUN Assignments Sun StorEdge 3310/3320 SCSI Array ================================ - Maximum number of LUNs per host ID is 32. - To achieve 128 partitions in a SCSI array, adjust the number of Logical Drives (LDs) and host IDs. For example: 4 host IDs x 4 LDs ==>32 x 4 = 128 LUNs Sun StorEdge 3510 FC/3511 SATA Array (Loop Mode) - 3.x Firmware ====================================== - 4 host channels per controller (0, 1, 4, and 5) - 8 host IDs per host channel (4 PID and 4 SID) - 32 logical unit numbers (LUNs) per host ID - 8 LDs per array - 128 LUNs or partitions for each LD Sun StorEdge 3510 FC/3511 SATA Array (Loop Mode) - 4.x Firmware ====================================== - 4 host channels per controller (0, 1, 4, and 5) - 8 host IDs per host channel (4 PID and 4 SID) - 32 logical unit numbers (LUNs) per host ID - 32 LDs per array - 32 LUNs or partitions for each LD For example: (4 host channels) x (8 IDs per channel) x (32 LUNs per ID) = 1024 LUNs per array Select the FC-AL protocol (loop mode) for environments needing more than 128 LUNs, or where a switched fabric network is not available. It is preferable that no more than four IDs be assigned to a controller on a given host channel. Sun StorEdge 3510 FC/3511 SATA Array (Point-to-Point Mode) ================================================ - 4 host channels per controller - 1 host ID per host channel. - 32 LUNs per host ID For example: (4 host channels) x (1 ID per channel) x (32 LUNs per ID) = 128 LUNs per array Note: If each LUN needs to have dual paths, then 64 dual pathed LUNs are available. Thus, in dual-controller configurations, either the primary or the secondary controller can have an ID assigned, but not both. Product Sun StorageTek 3310 SCSI Array Sun StorageTek 3320 SCSI Array Sun StorageTek 3510 FC Array Sun StorageTek 3510 2U FC Array Sun StorageTek 3511 SATA Array 3310, 3510, 3511. 3320, Minnow, host channels, PID, SID, lun, 3000 Previously Published As 75499 Change History Date: 2007-12-20 User Name: 7058 Action: Approved Comment: Updates OK to publish. Version: 7 Date: 2009-12-22 User Name: [email protected] Action: Currency & Update Date: 2007-12-20 User Name: 7058 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|