Solution Type Technical Instruction Sure Solution 1017944.1 : Sun StorEdge[TM] 3510 - What is the "Remote Redundant Controller" setting for?
PreviouslyPublishedAs 229213 Description On the firmware (tip/telnet) interface for the Sun StorEdge[TM] 3510 (SE3510) array, there is a menu entry for 'remote redundant controller' which can be either "enabled" or "disabled." It is disabled by default. The firmware manual (for 3.27) only mentions this parameter to say: Do not use these menu options. They are reserved for specific troubleshooting procedures and should only be used by qualified technicians. This seems very cryptic... What does this parameter do? Why does it need to remain 'disabled, and what could happen if you 'enable' it? Steps to Follow This parameter was originally introduced on previous Dothill arrays for enabling remote redundant controllers in separate chassis at remote locations. Neither Dothill nor Sun Microsystems support this type of hardware configuration on the SE3510 array, and therefore, this parameter (remote redundant controller) MUST remain 'disabled'. One odd thing that was seen when the variable was 'enabled' was a lack of correct controller failover when the primary controller failed. The next version of the firmware documentation will be changed to reflect this: Do not use the Remote Redundant Controller menu option. It is not supported by the RAID controller hardware. Product Sun StorageTek 3510 FC Array Previously Published As 80120 Change History Date: 2005-01-31 User Name: 71396 Action: Approved Comment: Performed final review of article Update product name and trademarking Publishing. Version: 3 Date: 2005-01-27 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2005-01-27 User Name: 38107 Action: Approved Comment: very helpful doc Version: 0 Date: 2005-01-27 User Name: 38107 Action: Accept Comment: Version: 0 Date: 2005-01-27 User Name: 38107 Action: Unlock Comment: Version: 0 Date: 2005-01-27 User Name: 26973 Action: Approved Comment: got this information right from dothill in response to an escalation i worked. Version: 0 Date: 2005-01-27 User Name: 26973 Action: Created Comment: Version: 0 Product_uuid 58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array Attachments This solution has no attachment |
||||||||||||
|