Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1001838.1
Update Date:2011-02-07
Keywords:

Solution Type  Technical Instruction Sure

Solution  1001838.1 :   Sun StorEdge[TM]3510 FC Array voltage sensor information.  


Related Items
  • Sun Storage 3510 FC Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
202515


Description
This document describes the voltage sensors for the Sun StorEdge[TM] 3510 FC Array. The sensor numbers are often seen from the array events messages. The information below should help you map the sensor numbers to a FRU.

Steps to Follow
Some examples of the messages you might see:
[3F3F] #22:  SES Device on StorEdge Array SN#8003306 CH2 ID12: ALERT:
voltage sensor state changed to critical (sensor 0)

[3F3F] #23:  SES Device on StorEdge Array SN#8003306 CH2 ID12: ALERT:
voltage sensor state changed to critical (sensor 1)

[3F3F] #24:  SES Device on StorEdge Array SN#8003306 CH2 ID12: ALERT: PS
0 power supply state changed to critical

[3F3f] #26:  SES Device on StorEdge Array SN#8014851 CH2 ID12: ALERT: PS 1 power supply state changed to critical


Voltage Sensors:
0  Voltage Sensor #1 for Left Power Supply 5V
1  Voltage Sensor #2 for Left Power Supply 12V
2  Voltage Sensor #3 for Right Power Supply 5V
3  Voltage Sensor #4 for Right Power Supply 12V
4  Voltage Sensor #5 on Upper IOM, 2.5V Local
5  Voltage Sensor #6 on Upper IOM, 3.3V Local
6  Voltage Sensor #7 on Upper IOM, Midplane 5V Power
7  Voltage Sensor #8 on Upper IOM, Midplane 12V Power
8  Voltage Sensor #9 on Lower IOM, 2.5V Local
9  Voltage Sensor #10 on Lower IOM, 3.3V Local
10 Voltage Sensor #11 on Lower IOM, Midplane 5V Power
11 Voltage Sensor #12 on Lower IOM, Midplane 12V Power


Here is a link to the Field replacement manual for FRU replacements.
http://download.oracle.com/docs/cd/E19957-01/816-7326-16/index.html



Product
Sun StorageTek 3510 FC Array

Internal Comments
For the internal use of Sun Employee's.

Here is a link to the FE hand book on the above FRU's
https://support.us.oracle.com/handbook_internal/Systems/3510/components.html
SE3510, sensor, temperature, voltage, events, messages