Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1017719.1
Update Date:2009-12-06
Keywords:

Solution Type  Technical Instruction Sure

Solution  1017719.1 :   Sun StorEdge[TM] 351x/33x0: Telnet session problems with 3.2x Controller Firmware  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3310 Array
  •  
  • Sun Storage 3511 SATA Array
  •  
  • Sun Storage 3320 SCSI Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
228928


Description

Summary

The telnet session may hang after a short period of time, when connected to a
Sun StorEdge[TM] 3510 FC, 3511[TM] SATA, and 33x0 SCSI arrays on a private network running 3.2x Controller Firmware.




Steps to Follow
The Ethernet connection is sensitive to voltage drops, noise potentials,
inductive transients and electromagnetic interference.

1. It is therefore highly recommended to use CAT5 (or better) cable from
the Minnows to switches or administration hosts. It is also important
to use short cables and stay within the limits for cable length.
2. Use a switch port capable of full-duplex operation for the most reliable operation.
3. Switch  ports should be configured for auto-negotiation.
4. Ensure the array is upgraded to Controller Firmware 4.x.


Product
Sun StorageTek 3511 SATA Array
Sun StorageTek 3510 FC Array
Sun StorageTek 3310 SCSI Array
Sun StorageTek 3320 SCSI Array

Internal Comments
For the internal use of Sun Employee's.

DH confirmed 3150 link negotiation problem with Cisco switches with cables 50 meters or longer. it is doing testing and signal analysis. It seems the the 4.0 based code is a lot more robust in this respect than 3.25 and 3.27. There may be a problem in the Ethernet driver handling link negotiation. it is not clear if FW4.0 alone can fix the bug completely.

For more information see Bug ID: 5034422.

SE3510, SE3310, SE3511, SE3320, minnow, TCP/IP, telnet, ethernet
Previously Published As
78532

Change History
Date: 2005-04-29
User Name: 111868
Action: Add Comment
Comment: we received following feedback
(ref http://krep.emea.sun.com/stats/equip_survey.cgi?month=200503)
Date: 2009-12-04