Solution  1003872.1 :   Sun StorEdge[TM] 3510 with non-default RCCom channels will require downtime for controller replacement.  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3511 SATA Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
205436


Description
A Sun StorEdge[TM] 3510 array using anything but the default channels (2 & 3) for Redundant Controller COMmunication (RCCom) may require system downtime in the event a controller replacement is necessary.


Steps to Follow
Users of Sun StorEdge[TM] 3510/3511 arrays with dual controllers have the option of moving the inter-controller communications function to unused channels to improve performance. System defaults are to use channels 2 and 3 as drive + RCCOM channels.

If a controller replacement becomes necessary, the replacement unit will likely come configured to attempt RCCOM communications on the default channels. If the existing controller is communicating on different channels, the two controllers will not crossload firmware or synchronize their actions, and both controllers will assume PRIMARY role. The array then becomes very difficult to manage, since both controllers are communicating via ethernet and they both write data to the serial port.

Suggested workaround: (requires downtime) Via serial port, telnet or sccli, change the channel settings so RCCOM is on channels 2 and 3. This requires controller reset. Then insert replacement controller.

Alternate workaround: (requires no downtime) Insert new controller into another unused array, connect via serial port, and change RCCOM channels to match the existing settings in the array needing the replacement. The controller can now be introduced into the array normally (HOT).



Product
Sun StorageTek 3511 SATA Array
Sun StorageTek 3510 FC Array

Internal Comments
Caution: This could potentially happen with mismatched controller firmware. This has not been tested.



minnow, RCCOM, controller, primary, nvram, firmware
Previously Published As
82191

Change History
Date: 2005-07-14
User Name: 97961
Action: Approved
Comment: Publishing. No further edits required.
Version: 4
Date: 2005-07-14
User Name: 97961
Action: Accept
Comment:
Version: 0
Date: 2005-07-14
User Name: 76672
Action: Approved
Product_uuid
9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array
58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback