Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1012024.1 : How To Resolve Sun StorEdge[TM] 351x Array: SES or PLD Firmware Mismatches
PreviouslyPublishedAs 216477
Applies to:Sun Storage 3511 SATA Array - Version: Not Applicable and later [Release: N/A and later]Sun Storage 3510 FC Array - Version: Not Applicable and later [Release: N/A and later] All Platforms GoalThis document illustrates what to look for if you receive the following message indicating a SES or PLD firmware mismatch.sccli> show ses * indicates SES or PLD firmware mismatch. SolutionResolution Based on the above output, you will need to upgrade your PLD firmware. You can get the firmware for your particular array from My Oracle Support (MOS).
After the PLD firmware upgrade, which could take 5 minutes, log out of the sccli> quit Then, log in again and run a show ses command, to verify there is no longer a sccli> show ses The PLD and SES firmware should be the same for both controllers. Internal Comments This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the âDocument Feedbackâ alias(es) listed below: [email protected] The Knowledge Queue for this article is KNO-STO-VOLUME_DISK. PLD, SES, SE3510, Minnow, firmware, firmware mismatch, 3510, audited, normalized, 3511, SE3511 Previously Published As 71538 Change History Date: 2009-12-24 User Name: [email protected] Comment: Currency & Update Date: 2007-07-03 User Name: 7058 Comment: OK to publish now. Attachments This solution has no attachment |
||||||||||||
|