Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1009253.1 : Sun StorEdge[TM] 3510/3511 FC Array: StorADE 2.4 Quick Installation and Configuration Guide.
PreviouslyPublishedAs 212803 Description This document is a quick installation guide for installing and configuring StorADE 2.4 for a Sun StorEdge 3510(SE3510) array. The installation is for a master StorADE server and must have a network connection to the array(s). With StorADE 2.4 installed you can monitor the array and have access to additional troubleshooting features. Important note about out-of-band access:
Notes:
Steps to Follow
If your java is at a lower revision you will be prompted to update your java revision. Failure to do so will result in unpredictable behavior of StorADE. Note: Hosts that do not have a data connection to the array will only be able to do out-of-band management of the array. Patch Installation ================== Get the latest patch 117650 from http://support.oracle.com/ and install it as user root: # patchadd 117650-xx To view the patch Click Here. Special note about array firmware: WARNING: Failure to upgrade the following devices to the minimum accepted firmware levels will result in failed discovery for the device.
Running ras_install ============================== As requested after package and patch installation, run the following: # /opt/SUNWstade/bin/ras_install Answer the questions asked in the script (the best way for the first install is to confirm the default answers): #opt/SUNWstade/bin/ras_install **** Installing the Package and Crons **** ? Are you installing a Master or a Slave Agent? (Enter M=master,S=slave,E=Empty Master)[M/S/E]: (default=M) M ? Do you want to turn on https security [Y/N](default=N) N ? Select language for GUI [en,B=Browser](default=B) B *** Master Install *** This script will now add the inet service to the inetd config file. /etc/services is now updated. /etc/inetd.conf is now updated. ? Do you want to C=start or P=stop the Agent cron [C/P] : (default=C) C ** cron installed. - Resetting the inetd services to see the new rashttp service. - Testing access to the webserver, (this will timeout after 30 secs) ... ***** ping 'sanconfig.france.sun.com' succeeded! 1/6 attempting to contact agent service... *** Contacted agent service (830ff810). SUNWstade installed properly! Filling the /etc/deviceIP.conf File ==================================== If the master StorADE server will use an out-of-band connection (refer to note in Description section) to monitor the SE3510 array, fill the following file: # vi /etc/deviceIP.conf # # Sample configuration file for devices that support IP discovery # # Enter device IP address and name # Note: The name is optional # # 10.0.0.1 switch1 # 10.0.0.2 T3b # SE3510 array 129.157.218.148 se3510-73g-a-epar02 3510 Note: The type of the array, "3510" in the example above, must be specified after the array name in the deviceIP.conf file. Discover the array with ras_admin =================== /opt/SUNWstade/bin # ./ras_admin discover_deviceIP Reading deviceIP: 10.1.229.114 storage-minnow-fc 3510 Start Discover::fromIP on 10.1.229.114 - found 1 device(s) Adding devices from deviceIP.local to configuration: adding device : storage-minnow-fc/206000c0ff004b07/ip=10.1.229.114 ************************************************************************** Site informatin has not been setup yet. Please run 'ras_admin site_info_upd' to complete installation. ************************************************************************** Update the site information =================== /opt/SUNWstade/bin # ras_admin site_info_upd Enter the proper site information. The lines with (*) are required. Setting up the sa_admin role and assigning users ==================== This step is required to be able to run diagnostic tests. create the sa_admin role # roleadd -c "SA Role" -s /bin/pfcsh -A "solaris.*" -P "All" sa_admin Assign a password to the sa_admin role. In this example, the password is fido. # passwd sa_admin ### Use password fido Create a user named admin assigned to the sa_admin role: # useradd -c "SA Admin" -s /bin/csh -R sa_admin -A "solaris.*" admin Assign the password to the user admin. In this example, the password is fido. # passwd admin ### Use password fido Configuring StorADE ==================== From any hosts that have network access to the master StorADE server, launch a web browser and type: https://<master_hostname>:6789 A login is required. Enter admin for the userid Select sa_admin for the role Enter fido for the password Follow the basic installation steps: 1. Review Site information. Enter all the mandatory information about the site, then click Submit 2. Click Inventory -> Name of the 3510 Once you have completed this setup, you should be able to have a report for the array. Diagnostic test are also available from this view. The installation is now completed. Product Storage Automated Diagnostic Environment 2.4 Sun StorageTek 3510 FC Array Sun StorageTek 3511 SATA Array Internal Comments For a more complete look at StorADE 2.4 installation please refer to: Sun Storage Automated Diagnostic Environment, Enterprise Edition, Version 2.4, Release Notes se3510, 3510, storade, 2.3, minnow, deviceIP.conf, monitoring, discovery, 3.27r Previously Published As 77344 Change History Date: 2006-02-15 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2006-02-15 User Name: 109562 Action: Approved Comment: Note: Document 75821 is also a quick install guide but addresses versions 2.2 and 2.3 of storade. Added comment so that reader knows that this document contains examples Version: 0 Date: 2006-02-14 User Name: 109562 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|