Solution Type Technical Instruction Sure Solution 1012786.1 : Sun StorEdge[TM] 351x FC Array: Unable to set scsi-3 persistent reservations
PreviouslyPublishedAs 217562 Description A Sun StorEdge[TM] 351x FC Array seems to be functioning, but cluster software is unable to set any scsi-3 reservations on the array. Steps to Follow The Sun StorEdge 351x FC Array had lds which were removed and recreated. After they were recreated, cluster was unable to reserve the "new" lds. The array showed the lds as optimal. Customer attempted to run: # /usr/cluster/lib/sc/scsi -c inkeys -d /dev/did/rdsk/d5s2 do_scsi3_inkeys failed Reservation keys(0): The error in /var/adm/messages at the time: May 17 23:14:16 host device busy too long May 17 23:14:16 host Cluster.CCR: [ID 826747 daemon.warning] reservation error(node_join) - do_scsi3_inkeys() error for disk /dev/did/rdsk/d5s2 The reservations needed to be cleared at the array level. From any host connected to the array, unmount the volumes. Confirm that you have a host with serial access to the array. On the host managing the array, run sccli: # /usr/sbin/sccli Choose the correct array if multiple are connected to the host. Run the command to shutdown the controller, it is necessary to sync the cache to the disks so that the LDs remain consistent. sccli> shutdown controller Reset the controller sccli> reset controller From the host with serial port access Watch the boot up until you find message ======================================================================== Restoring saved persistent reservations. Preparing to restore saved persistent reservations. Type 'skip' to skip: ======================================================================== Type skip which will skip the loading of any persistent reservation keys stored on the array, essential scrubbing them from the array. Allow the array to continue to boot normally. At this time, retry the cluster command to initiate scsi-3 reservations. The reset on the array needs only be run once. If any reservations on any hosts exist prior to this procedure, the host will no longer have access to the lds, and could result in a panic of that host, or an ejection from the cluster. Product Sun StorageTek 3510 FC Array Sun Cluster 3.0 Internal Comments Similar to: Issue in Technical Instruction <Document: 1010599.1> . Firmware was at current rev (4.11i). minnow, scsi-3, persistant, reservations, cluster, se3511, se3510, se351x Previously Published As 85841 Change History Date: 2006-06-06 User Name: 97961 Action: Approved Comment: - Changed title to comply to the standard format - Applied trademarking - Made simple sentence/grammatical corrections - Tidied up formatting Version: 3 Date: 2006-06-06 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2006-06-06 User Name: 124974 Action: Approved Comment: The document looks good. Attachments This solution has no attachment |
||||||||||||
|