Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1017748.1 : How to Set the Date of Sun Storage[TM] 351x Array Batteries After Replacement
PreviouslyPublishedAs 228960 After replacement of a Sun Storage[TM] 3510 FC or 3511 SATA Array battery for expiration,
Applies to:Sun Storage 3310 SCSI ArraySun Storage 3320 SCSI Array Sun Storage 3510 FC Array Sun Storage 3511 SATA Array All Platforms The following command return an error : sccli > show battery-status sccli: Upper Battery: error: in service date not set in the battery sccli: Lower Battery: error: in service date not set in the battery GoalThis document will explain how to set the Battery in-service date.SolutionSteps To FollowRun the command :sccli> show battery-status -u The show battery-status -u command sets the in-service date to the battery board sccli> show battery-status Upper Battery Type: 1 Lower Battery Type: 1 Change History Date: 2010-11-30 User Name: [email protected] Action: Currency & Update Date: 2005-10-24 Attachments This solution has no attachment |
||||||||||||
|