Solution Type Technical Instruction Sure Solution 1021453.1 : How to avoid the probe-scsi-all command hanging the system when there are multiple hosts on the same Fibre Channel Loop
PreviouslyPublishedAs 271929 Description At the OBP prompt, the probe-scsi-all command may cause host(s) to hang, when there are multiple hosts connected to the same fibre channel loop. When we configure hosts to boot from the StorageTek[tm] 3510 FC array that are configured on the same fibre channel loop, if a probe-scsi-all command is issued at the OBP prompt on one host, other hosts might not be able to boot from OBP due to CR: 4589231's effect. CR 4589231 probe-scsi-all ; boot -v kills LILP map and topology discovery process Also see related CR: 6904697 Synopsis: probe-scsi-all should cause the hosts hang RFE. If other hosts are running, it might cause those hosts to hang with 'Loop OFFLINE' message. The following is the message outputted from a running host when issued probe-scsi-all on the other server. Sep 23 17:25:59 xxxxxx lw8: [ID 555425 kern.notice] Main, up 53 days 00:51:16, Memory 8,755,544 Sep 23 21:25:59 xxxxxx lw8: [ID 944324 kern.notice] Main, up 53 days 04:51:16, Memory 8,591,008 Sep 24 00:57:59 xxxxxx qlc: [ID 630585 kern.info] NOTICE: Qlogic qlc(2): Loop OFFLINE Sep 24 05:35:38 xxxxxx genunix: [ID 540533 kern.notice] ^MSunOS Release 5.10 Version Generic_118833-24 64-bit Sep 24 05:35:38 xxxxxx genunix: [ID 172907 kern.notice] Copyright 1983-2006 Sun Microsystems, Inc. All rights reserved. We tested in the following environment. [env] V480 x2 + SE3510 V480-a:PCI#0 ---- SE3510:Controller#A CH0 V480-a:PCI#1 ---- SE3510:Controller#B CH1 V480-b:PCI#0 ---- SE3510:Controller#A CH1 V480-b:PCI#1 ---- SE3510:Controller#B CH0 - HBA: P/N(375-3363), FW(1.17), Jumper(1-2) - SE3510:Controller P/N(371-0532), FW(4.21F) -------------------- test 1 (reproduced) -------------------- (1) v480a poweron (2) v480b poweron (3) v480a probe-scsi-all (4) v480b probe-scsi-all (5) v480a boot <-- boot fail (6) v480b boot <-- boot fail -------------------- test 2(reproduced, though changed v480a v480b boot order) -------------------- (1) v480b poweron (2) v480a poweron (3) v480b probe-scsi-all (4) v480a probe-scsi-all (5) v480b boot <-- boot fail (6) v480a boot <-- boot fail -------------------- test 3(not reproduced if one node boot earlier) -------------------- (1) v480a poweron (2) v480a probe-scsi-all (3) v480a boot (4) v480b poweron (5) v480b probe-scsi-all (6) v480b boot -------------------- test 4(not reproduced if issue reset-all after probe-scsi) -------------------- (1) v480a poweron (2) v480b poweron (3) v480a probe-scsi-all (4) v480a reset-all (5) v480b probe-scsi-all (6) v480b reset-all (7) v480a boot (8) v480b boot -------------------- Test log snip -------------------- - power on v480a and v480b - doing probe-scsi-all on v480a =================== {2} ok probe-scsi-all /pci@9,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 2100000c50ac5725 SEAGATE ST336605FSUN36G 0638 1 1 0 2100000c50696a0c SEAGATE ST336607FSUN36G 0307 /pci@8,600000/SUNW,qlc@2,1 QLA2342 Host Adapter fcode version 1.17 08/09/07 Firmware version 3.03.23 Link not ready - Loss of Sync /pci@8,600000/SUNW,qlc@2 QLA2342 Host Adapter fcode version 1.17 08/09/07 Firmware version 3.03.23 *************************** Local Loop Devices *************************** Adapter LoopId - 0 Device AL-PA a5 loopId 2a Hard-addr 2a Port WWN 226000c0ffa01f53 Lun 0 SUN StorEdge 3510 413C Device AL-PA a3 loopId 2b Hard-addr 2b Port WWN 226000c0ffb01f53 Lun 0 SUN StorEdge 3510 413C /pci@8,600000/SUNW,qlc@1,1 QLA2342 Host Adapter fcode version 1.17 08/09/07 Firmware version 3.03.23 Link not ready - Loss of Sync /pci@8,600000/SUNW,qlc@1 QLA2342 Host Adapter fcode version 1.17 08/09/07 Firmware version 3.03.23 *************************** Local Loop Devices *************************** Adapter LoopId - 0 Device AL-PA a7 loopId 28 Hard-addr 28 Port WWN 216000c0ff801f53 Lun 0 SUN StorEdge 3510 413C Device AL-PA a6 loopId 29 Hard-addr 29 Port WWN 216000c0ff901f53 Lun 0 SUN StorEdge 3510 413C =================== Issue probe-scsi-all on v480b. =================== {2} ok probe-scsi-all /pci@9,600000/SUNW,qlc@2 LiD HA LUN --- Port WWN --- ----- Disk description ----- 0 0 0 21000004cf98a7bd SEAGATE ST373405FSUN72G 0638 1 1 0 21000004cf989c39 SEAGATE ST373405FSUN72G 0638 /pci@8,600000/SUNW,qlc@2,1 QLA2342 Host Adapter fcode version 1.17 08/09/07 Firmware version 3.03.23 Link not ready - Loss of Sync /pci@8,600000/SUNW,qlc@2 QLA2342 Host Adapter fcode version 1.17 08/09/07 Firmware version 3.03.23 Link not ready - Waiting for AL_PA /pci@8,600000/SUNW,qlc@1,1 QLA2342 Host Adapter fcode version 1.17 08/09/07 Firmware version 3.03.23 Link not ready - Loss of Sync /pci@8,600000/SUNW,qlc@1 QLA2342 Host Adapter fcode version 1.17 08/09/07 Firmware version 3.03.23 Link not ready - Waiting for AL_PA =================== Steps to Follow The following steps are the suggested workaround. If all systems on the same fibre channel loop are at the OBP prompt: issue a 'reset-all' after performing the "probe-scsi-all" command. If any systems on the shared fibre channel loop are up and running, do not issue a 'probe-scsi-all' without first shutting down those machines. Product Sun StorageTek 3510 FC Array probe-scsi-all, shared loop, hung, se3510, minnor, 3510, 3510 Array, OBP Product_uuid 58553d0e-11f4-11d7-9b05-ad24fcfd42fa Attachments This solution has no attachment |
||||||||||||
|