Solution Type  Technical Instruction Sure

Solution  1005597.1 :   How do I configure a local/global spare on a Sun Storage 3310, 3320, 3510 or 3511 Array? [Video]  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3310 Array
  •  
  • Sun Storage 3511 SATA Array
  •  
  • Sun Storage 3320 SCSI Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  
  • GCS>Support>KM>Content>Video
  •  

PreviouslyPublishedAs
207769


Applies to:

Sun Storage 3310 SCSI Array
Sun Storage 3320 SCSI Array
Sun Storage 3510 FC Array
Sun Storage 3511 SATA Array
All Platforms

Goal

Description

This document describes how to configure a spare on a Sun Storage 3000 series array.
Video - Configuring a Global and Local Spare (05:00)


Sunsolve users must download the attachment to view the video.

Solution


Steps to Follow

How do I configure a local/global spare on a Sun  Storage 3310, 3320, 3510 or 3511 Array?

In this example, the global spare is created on disk 3.0

Create Global Spare with sccli:

# sccli configure global-spare 3.0

In this example we created a local spare from disk 3, logical drive 0.

Create Local Spare with sccli:

# sccli configure local-spare 3.0  ld0

Create Global or Local Spare with telnet or serial connection:

1.  Telnet or tip thru serial port to array.

# telnet 10.1.229.120

10.1.229.120 is the address of your Sun StorEdge disk.

Or

# tip -38400 /dev/ttyb

2.  Select  view and edit Drives 

3.  Select a disk drive in the table.

4.  Select either  add Local spare drive  or  add Global spare drive  from the submenu.

5.  For local spares, select the logical drive that the spare will be associated.

5.  Select 'yes' when prompted.

See the following InfoDoc for additional troubleshooting information:

<Document: 1005313.1> Troubleshooting StorEdge 33x0/ 351x Configuration