Problem Document
|
Former IBIS ID
|
Synopsis
|
Last Modified Date
|
1020543.1 |
260468 |
Sun Fire[TM] 12K/15K/20K/25K: Esmd reports false voltage alarms on HPCI boards |
2011-02-02
|
1019902.1 |
248546 |
"showboards" may report invalid power values when the locale is not set to "C" |
2011-01-26
|
1018867.1 |
230667 |
Sun Fire[TM] 12K/15K/E20K/E25K: Mailbox Framework Failures, Even Without DR Operation |
2011-02-04
|
1018155.1 |
229505 |
Sun Fire[TM] 12K/15K Servers : prtdiag reports "/IO31/P3" for SlotId and "-1" for PortId. |
2010-06-21
|
1018065.1 |
229375 |
Virtual Console Daemon (cvcd) fails to start on a Solaris[TM] 10 High End Server domain. |
2011-02-02
|
1017937.1 |
229199 |
Sun Fire[TM] 12K/15K/E20K/E25K: UltraSPARC[R] IV Processors report over-temperature events. |
2011-01-12
|
1017727.1 |
228936 |
System Management Services (SMS) 1.3 or older: flashupdate unable to flash boards with 5.19.X or newer |
2010-09-20
|
1017493.1 |
228616 |
Sun Fire[TM] 12K/15K/E20K/E25K: Cheat Sheet: hsPCI, hsPCI+ and hsPCI-X Cartridge Locations |
2011-04-19
|
1012322.1 |
217005 |
System Management Services: The smsconnectsc command fails with "all ports busy" or just hangs. |
2010-06-15
|
1012320.1 |
217002 |
Sun Fire[TM] 12K/15K/20K/25K: Domain reports "sun-dr/tcp: bind: Address already in use" |
2010-06-29
|
1012044.1 |
216503 |
Sun Fire[TM] 12K/15K: Recognizing SMS split brain |
2011-05-26
|
1011843.1 |
216224 |
Sun Fire[TM] 15K server: Duplicate Open Boot Prom (OBP) devaliases may prevent the system from booting |
2009-02-08
|
1011106.1 |
215279 |
Fabric devices and QuickLoop devices exported to Solaris [TM] via the same Fiber Channel connection. |
2010-01-28
|
1010957.1 |
215113 |
"uname -a" on a Sun Fire[TM] 12K/20K/25K reports Sun-Fire[TM]15000 |
2010-12-20
|
1010924.1 |
215073 |
Sun Fire[TM] Server : Dynamic Reconfiguration (DR) fails due to Real Time (RT) process running. |
2011-01-30
|
1010750.1 |
214835 |
Sun Fire[TM] 12K/15K/E20K/E25K: Domain fails HPOST test "PCI IOC External Functional Tests,SUBTEST=PCI IOC DMA External loopback Tests" |
2011-05-26
|
1010722.1 |
214797 |
Sun Fire[TM] 12K/15K/E20K/E25K: Error message "cfgadm: Hardware specific failure: unconfigure SB2: Failed to off-line: dr@0:SB2::cpu2" |
2011-02-09
|
1010705.1 |
214778 |
Reboot of one domain, 2 others dstop with ?Timeout on head of CI queue? |
2011-01-12
|
1010600.1 |
214583 |
Sun Fire[TM] 12K/15K/E20K/E25K: "Domain failed by hpost: ecode=39" |
2010-06-18
|
1010336.1 |
214178 |
Sun Fire[TM] 12K/15K: FOMD error 8563 - failed to configure logical interface |
2009-09-15
|
1010335.1 |
214177 |
Sun Fire[TM] 12K/15K/E20K/E25K: Identifying and recovering from a domain hang |
2011-05-10
|
1009696.1 |
213337 |
"kstat -p" and "prtdiag -v" may give seemingly different PCI bus speeds for Dual Fast Ethernet and Dual SCSI PCI Adapters |
2010-07-06
|
1009533.1 |
213152 |
Sun Fire[TM] 12K/15K/20K/25K: DR not possible when CSB is blacklisted and domain configured with both Centreplane halves active |
2010-06-18
|
1009267.1 |
212826 |
cfgadm: Component system is busy, try again |
2010-06-15
|
1009206.1 |
212741 |
How to remove unwanted aliases in NVRAM; nvunalias does not remove them from NVRAM, still show when run "devalias" |
2009-11-29
|
1009124.1 |
212618 |
Sun Fire[TM] 12K/15K/E20K/E25K: showdevices takes a long time to return |
2010-05-27
|
1008914.1 |
212263 |
Sun Fire[TM] 15K: Console stuck in IOSRAM mode |
2010-06-14
|
1008905.1 |
212253 |
Sun Fire[TM] 12K/15K/E20K/E25K: Safari Agent ID Cheat Sheet and Decoding CPU, Memory, and IOC Locations |
2011-04-07
|
1008904.1 |
212252 |
Sun Fire[TM] 15K server: Adding a user with the smsconfig command |
2009-09-28
|
1008879.1 |
212221 |
Sun Fire[TM] 15K: Running diagnostics on System Controller |
2009-09-21
|
1008805.1 |
212092 |
Sun Fire[TM] 12K/15K/E20K/E25K: Remote Dynamic Reconfiguration (DR) generates "DCA/DCS Communication Error" and showdevices is ?Unable to get device information from domain?. |
2011-05-09
|
1008803.1 |
212090 |
Sun Fire[TM] 12K/15K: showdevices can hang if sd.conf is large or misleading |
2010-01-27
|
1008719.1 |
211973 |
Resolving Hardhang problems on Ultra Servers |
2011-04-21
|
1007966.1 |
210986 |
Sun Fire[TM] 12K/15K E20K/E25K servers: Can't setkeyswitch domains. POST aborts with ecode=2 |
2011-05-11
|
1007939.1 |
210950 |
Sun Fire[TM] 12K/15K/E20K/E25K: Solaris[TM] 10 DR detach of IO Board containing the dman interface fails with "Device busy: dr@0:IO<##>::pci2" |
2010-11-23
|
1007790.1 |
210776 |
Sun Fire[TM] 12K/15K/E20K/E25K: System Controller (SC) platform messages file reports "FRAD chkpt WRITE failed. session id: 128, return code: 8" errors. |
2009-09-01
|
1007782.1 |
210767 |
Dynamic Reconfiguration or hot plug problems on a QGE HBA (4444A). |
2010-05-27
|
1007768.1 |
210753 |
Sun Fire[TM] 15K: Reply for ssc-seteeprom command failed |
2009-09-28
|
1007736.1 |
210714 |
Diagnosing multiple DIMM CE errors occurring on multiple DIMMs |
2010-12-28
|
1007730.1 |
210708 |
Sun Fire[TM] 12K/15K/E20K/E25K: showdevices command fails on system controller |
2011-01-04
|
1007619.1 |
210538 |
Sun Fire [TM] 15k (12k) system controller gives message WARNING: pcipsy0: spurious interrupt from ino 0x1c |
2011-05-02
|
1007591.1 |
210502 |
Sun Fire[TM] 12K, 15K, E20K, E25K: OpenBoot[TM] Prom no Longer Accepts Shortened Disk Boot Device Paths in System Management Services (SMS) 1.4.1 |
2011-01-24
|
1006864.1 |
209529 |
Sun Fire[TM] Mid Range and High end servers: Dynamic Reconfiguration for Uniboard removal may cause Lotus Domino server instance(s) to abnormally stop |
2010-05-26
|
1006728.1 |
209372 |
Connection to Nile proxy is down and could not be re-established, remote reporting aborted. |
2011-01-03
|
1006575.1 |
209180 |
Sun Fire[TM] 12K/15K/E20K/E25K: After upgrading hsPCI to hsPCI+ domain fails to boot |
2011-04-26
|
1006505.1 |
209103 |
Best Practice for EMC Array Special LUN when connected to system running Solaris[TM] Operating System |
2011-03-24
|
1006491.1 |
209087 |
Sun Fire[TM] 12K/15K/E20K/E25K: System Controller /var/adm/messages shows many eri "link up" (and sometimes "link down") messages |
2010-09-01
|
1006327.1 |
208878 |
Sun Fire[TM] 12K/15K/E20K/E25K: The "setkeyswitch on" command fails with "FAIL Addr Bus C1: Cplane already in use with this bus deconfigured." |
2009-12-02
|
1006302.1 |
208841 |
Sun Fire[TM] 15k: Domain not Booting: "Domain failed by hpost: ecode=36" |
2010-05-27
|
1006249.1 |
208764 |
Sun Fire[TM] 12K/15K/E20K/E25K: Solaris[TM] 8 domain hangs on resuming JNI I/O device driver |
2011-02-17
|
1006233.1 |
208741 |
Sun Fire[TM] Servers: Interpreting System Management Services(SMS) Failed Power Supply Messages |
2010-12-27
|
1006217.1 |
208701 |
Sun Fire[TM] System Controller: Warning Message Appears After the CP1500 Board Replacement |
2011-01-19
|
1006156.1 |
208621 |
"ERROR: Can't open boot device" booting CDROM or disk with Sun[TM] Dual FastEthernet / Dual SCSI PCI Card |
2010-07-06
|
1006088.1 |
208489 |
Sun Fire[TM] 12K/15K/E20K/E25K: Dstop: AMX: Detected Header parity error from AXQ |
2011-01-12
|
1006050.1 |
208437 |
Sun Fire[TM] 12K/15K/E20K/E25K: Interrupt not serviced messages on System Controller |
2009-12-02
|
1006045.1 |
208431 |
Sun Fire[TM] 12K/15K/E20K/E25K: Incomplete removal of dynamic reconfiguration (DR) capability may lead to network hangs |
2011-06-06
|
1005856.1 |
208141 |
Sun Fire[TM] 15K server: Domain Automated System Recovery (ASR) is disabled for one or more domains |
2009-09-28
|
1005038.1 |
207089 |
Sun Fire[TM] 12K/15K/E20K/E25K: Domain Reboots if the Open Boot PROM Boot Device Is Incorrect |
2011-04-26
|
1004782.1 |
206640 |
probe-scsi-all can see disks, but boot -r, devfsadm , and drvconfig, fail to add disks to OS |
2011-05-27
|
1004712.1 |
206542 |
Sun Fire[TM] 12K/15K/E20K/E25K: Domain reboot hangs at "resetting..." and does not run HPOST |
2009-12-03
|
1004618.1 |
206404 |
Sun Fire[TM] 12K/15K: frad daemon reports "Ignoring CRC error" or "TH Segment CRC is wrong on DIMM" |
2011-04-26
|
1004598.1 |
206377 |
Sun Fire[TM] 12K/15K/E20K/E25K: Recovering from a System Controller disk failure |
2010-06-10
|
1003853.1 |
205408 |
Sun Fire[TM] 12/15/20/25K server found with DC Breaker in the 'off' position |
2010-07-20
|
1003727.1 |
205251 |
System Management Services: Upgrading SMS 1.3 to 1.4.1 fails with smsrestore error |
2009-09-23
|
1003585.1 |
205060 |
Sun Fire [TM] 12K/15K: Cards Fail to be Configured in I/O Board Slot 1 if Slot 3 is Populated |
2010-08-27
|
1003552.1 |
204998 |
Sun Fire[TM] 12K/15K/E20K/E25K: SC POST results: 'Power On Selftest not run on last reset' |
2010-06-07
|
1003550.1 |
204994 |
Sun Fire[TM] 12K - E25K / Sparc Enterprise Mx000: WARNING: fcode_timer: Timeout waiting for interpreter - Interpreter did not pick up request |
2011-01-04
|
1003483.1 |
204885 |
Oracle database restart takes longer on high end systems running Solaris[TM] 8 |
2010-08-03
|
1003436.1 |
204819 |
Sun Fire[TM] 12K/15K: Post failure on Domain Advanced Tests |
2009-09-27
|
1003334.1 |
204629 |
Sun Fire[TM] 12K/15K: WARNING: mod_load: cannot load module 'scman' |
2009-12-03
|
1003308.1 |
204588 |
Sun Fire[TM]12K/15K/E20K/E25K: esmd warning; A power failure has been detected on a redundant power supply at ... |
2010-09-22
|
1002804.1 |
203828 |
Sun Fire[TM] 12K/15K/E20K/E25K: Hpost fails an IO board which "Shares an expander with an unthrottled USIV+ board which is active in another domain." |
2010-08-19
|
1002762.1 |
203778 |
Sun Fire[TM] 12K/15K/E20K/E25K: Seeprom never went ready errors after platform power on. |
2010-06-10
|
1002642.1 |
203643 |
SMS Failover is disabled due to I2 network failure running on Solaris[TM] 10 Operating System with patch 122608-03 installed |
2011-05-12
|
1002437.1 |
203410 |
Sun Fire[TM] 12K/15K/20K/25K: cfgadm -c disconnect fails with Library error: RCM request delete capacity failed for SB |
2010-06-18
|
1002417.1 |
203384 |
Missing drv/clone forceload in /etc/system on a system with Emulex cards may cause panic during boot |
2010-06-07
|
1002125.1 |
203025 |
Sun Fire[TM] 15K/12K/E20K/E25K Servers: RCM Daemon hanging, causing DR operations to hang |
2009-12-01
|
1002119.1 |
203019 |
Sun Fire[TM] 12K/15K/E20K/E25K: "Error reading E$Dimm SBxx/P[0,1]/E[0,1] seeprom" reported for a 2-cpu board. |
2011-01-05
|
1002017.1 |
202816 |
Sun Fire[TM] 12K and 15K: SunSAI/P serial port expansion cards are not compatible with Sun Fire servers |
2011-03-08
|
1002001.1 |
202789 |
Sun Fire[TM] Servers: 12K/15K/E25K/E20K: Post passed but CPUs are missing under Solaris[TM] |
2010-06-17
|
1001923.1 |
202678 |
Sun Fire[TM] 12K/15K/E20K/E25K: smsconnectsc command gives "Unable to obtain a lock." errors |
2009-09-27
|
1001848.1 |
202532 |
Sun Fire[TM] 12K/15K Server: Terminating a hpost reset/recovery loop test cycle on a domain |
2009-09-27
|
1001651.1 |
202247 |
Sun Fire[TM] 15K server: Displaying domain ethernet addresses from the system controller |
2009-12-01
|