Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1002437.1 : Sun Fire[TM] 12K/15K/20K/25K: cfgadm -c disconnect fails with Library error: RCM request delete capacity failed for SB
PreviouslyPublishedAs 203410 Symptoms When running cfgadm -c disconnect SB?, I an error: Library error: RCM request delete capacity failed for SB? Place the dr session into debug SBD_DEBUG=/tmp/sbd.log;export SBD_DEBUG rerun the cfgadm -c disconnect SB? Looking at the /tmp/sbd.log shows we are failing with a bad address: ....snip .... Resolution This error will occur if /var/run is not mounted as tmpfs. Using mount -p /var/run should be mounted as a tmpfs filesystem. # mount -p ...... swap - /var/run tmpfs - no xattr ...... Running Solaris[TM] 8 and Solaris[TM] 9, /var/run is mounted in the /etc/rcS.d/S70buildmnttab.sh. Note : Additional Information For further details, see : Bug 5088931 - deleteboard cmd results in rcm library error Product Sun Fire E25K Server Sun Fire E20K Server Sun Fire 15K Server Sun Fire 12K Server rcm, cfgadm, disconnect, deleteboard Previously Published As 83347 Change History Date: 2010-04-30 User Name: Cootware Action: Content Team Review Comment: Updated title to reflect error. Attachments This solution has no attachment |
||||||||||||
|