Solution Type Problem Resolution Sure Solution 1006302.1 : Sun Fire[TM] 15k: Domain not Booting: "Domain failed by hpost: ecode=36"
PreviouslyPublishedAs 208841 Symptoms The domain is not booting and displays the following message at the end of the POST output: Exitcode = 36: Non-configuration special hpost mode successful POST (level=32, verbose=40) execution time 6:27 [5304] Domain failed by hpost: ecode=36 Resetting and deconfiguring: CPU at SB16 Resetting and deconfiguring: HPCI at IO16 Resetting and deconfiguring: EXB at EX16 Resolution When running hPOST to check a single SB, a new domain is created and two flags are added to the .postrc file: no_ioadapt_ok <= only SB will be tested no_obp_handoff <= control won't be sent to OBP after finishing POST When you later attempt to boot the domain, these flags set in the .postrc file will cause the boot to fail. The keyswitch mode reverts to "standby". The solution is to remove both lines from the .postrc file. Additional Information .postrc example ================ /etc/opt/SUNWSMS/SMS1.3/config/R/.postrc: verbose 40 err_print 64 level 32 no_ioadapt_ok no_obp_handoff Product Sun Fire 15K Server Sun Fire 12K Server Internal Comments This solution is intended for use by Sun IT and Sun IT Partner Engineers only. <Document: 1007568.1> contains the procedure to test a single slot 0 board w/o any IO f15k, sms, 1.3, boot, no_ioadapt_ok, no_obp_handoff, ecode=36, setkeyswitch, standby Previously Published As 75762 Updated by the ESG Knowledge Content Team 4/2010 Attachments This solution has no attachment |
||||||||||||
|