Solution Type  Problem Resolution Sure

Solution  1007730.1 :   Sun Fire[TM] 12K/15K/E20K/E25K: showdevices command fails on system controller  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
210708


Applies to:

Sun Fire 12K Server
Sun Fire 15K Server
Sun Fire E20K Server
Sun Fire E25K Server
Sun SPARC Sun OS

Symptoms

When attempting to run the showdevices command on the SF15K-SF25K system controller the following messages can be seen in the /var/opt/SUNWSMS/adm/platform/messages file:

Mar 22 14:21:25 2005 epttsp80-sc1 kmd[2509]: [0 928926673615195 ERR KMDDomainInterface.cc 311] mbox reply status 2, sadb_msg_errno =22
Mar 22 14:21:25 2005 epttsp80-sc1 kmd[2509]: [0 928926720969106 ERR KMDDomainInterface.cc 311] mbox reply status 2, sadb_msg_errno =22
Mar 22 14:21:25 2005 epttsp80-sc1 kmd[2509]: [0 928926917991364 ERR KMDDomainInterface.cc 311] mbox reply status 2, sadb_msg_errno =22
Mar 22 14:21:25 2005 epttsp80-sc1 kmd[2509]: [0 928926961544058 ERR KMDDomainInterface.cc 311] mbox reply status 2, sadb_msg_errno =22
Mar 22 14:21:25 2005 epttsp80-sc1 kmd[2509]: [0 928927001096862 ERR KMDDomainInterface.cc 311] mbox reply status 2, sadb_msg_errno =22
Mar 22 14:21:25 2005 epttsp80-sc1 kmd[2509]: [0 928927123263614 ERR KMDDomainInterface.cc 311] mbox reply status 2, sadb_msg_errno =22
Mar 22 14:21:25 2005 epttsp80-sc1 showdevices[12540]: [0 928927212569570 ERR ri_init.cc 85] rcfgaRequestProxy->ri_init failed. status= 4314
Mar 22 14:21:25 2005 epttsp80-sc1 showdevices[12540]: [4509 928927233061616 ERR RcfgaCallback.cc 521] server accept failed. RcfgaCallback::serverAccept: failed in ioctl domain id = A

Cause

The domain may not have a dman interface plumbed.

Solution

Steps to follow:

1) Log into the domain as superuser.


2) Type:

# ndd -get /dev/dman man_get_hostinfo

The following is an example of the output displayed.

manc_magic = 0x4d414e43
manc_version = 01
manc_csum = 0x0
manc_ip_type = AF_INET
manc_dom_ipaddr = 10.1.1.3
manc_dom_ip_netmask = 255.255.255.224
manc_dom_ip_netnum = 10.1.1.0
manc_sc_ipaddr = 10.1.1.1
manc_dom_eaddr = 0:0:be:a8:48:26
manc_sc_eaddr = 8:0:20:f9:e4:54
manc_iob_bitmap = 0x400 io boards = 10.1,
manc_golden_iob = 10


3) Add or edit a network-i1 entry to /etc/netmasks, using the following format

<manc_dom_ip_netnum>   <man_dom_ip_netmask>

For example:
10.1.1.0   255.255.255.224


4) Create an /etc/hostname.dman0 file with the following content:

<manc_dom_ipaddr> netmask + broadcast + private up

For example:
10.1.1.3   netmask + broadcast + private up


5) Ensure that the 'manc_sc_ipaddr' IP address matches whats in /etc/syslog.conf

# cat /etc/syslog.conf
--snip--
*.notice @10.1.1.1
--snip--

If not, edit the /etc/syslog.conf file. Save and exit.


6) Type:

# ifconfig dman0 plumb
# ifconfig dman0 netmask + broadcast + private up

For example:
# ifconfig dman0 plumb
# ifconfig dman0 10.1.1.3 netmask + broadcast + private up


Product

Sun Fire E25K Server
Sun Fire E20K Server
Sun Fire 12K Server
Sun Fire 15K Server

Internal Comments
Documented in Bug id 4627344

showdevices, dman, RcfgaCallback, KMDDomainInterface.cc
Previously Published As 80864

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback