Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1007730.1 : Sun Fire[TM] 12K/15K/E20K/E25K: showdevices command fails on system controller
PreviouslyPublishedAs 210708
Applies to:Sun Fire 12K ServerSun Fire 15K Server Sun Fire E20K Server Sun Fire E25K Server Sun SPARC Sun OS SymptomsWhen attempting to run the showdevices command on the SF15K-SF25K system controller the following messages can be seen in the /var/opt/SUNWSMS/adm/platform/messages file:Mar 22 14:21:25 2005 epttsp80-sc1 kmd[2509]: [0 928926673615195 ERR KMDDomainInterface.cc 311] mbox reply status 2, sadb_msg_errno =22 CauseThe domain may not have a dman interface plumbed.SolutionSteps to follow:1) Log into the domain as superuser. 2) Type: # ndd -get /dev/dman man_get_hostinfo The following is an example of the output displayed. manc_magic = 0x4d414e43 3) Add or edit a network-i1 entry to /etc/netmasks, using the following format <manc_dom_ip_netnum> <man_dom_ip_netmask> For example: 10.1.1.0 255.255.255.224 4) Create an /etc/hostname.dman0 file with the following content: <manc_dom_ipaddr> netmask + broadcast + private up For example: 10.1.1.3 netmask + broadcast + private up 5) Ensure that the 'manc_sc_ipaddr' IP address matches whats in /etc/syslog.conf # cat /etc/syslog.conf If not, edit the /etc/syslog.conf file. Save and exit. 6) Type: # ifconfig dman0 plumb # ifconfig dman0 netmask + broadcast + private up For example: # ifconfig dman0 plumb Product Sun Fire E25K Server Sun Fire E20K Server Sun Fire 12K Server Sun Fire 15K Server Internal Comments Documented in Bug id 4627344 showdevices, dman, RcfgaCallback, KMDDomainInterface.cc Previously Published As 80864 Attachments This solution has no attachment |
||||||||||||
|