Symptoms
After a platform power on, multiple system boards and or expanders fail post with error "Seeprom never went ready". These may also be accompanied by messages "unable to determine board type in slot SBx".

Resolution
On applying power to the platform the system controller cpu boards will immediately start post, then Solaris[TM], and then SMS. If the obp is not set to run the SCCPOST the I2C network will not be fully ready to probe all the devices when SMS starts.
Check the main sc's obp settings and ensure they are set as follows:
On SC0: diag-level pmax-epmax
On SC1: diag-level pmax-epvmax
On both SC's diag-switch? true
On both SC's post-on-sir?=true
Once these are set the main sc will need to be rebooted. These settings need to be maintained on the
SC's to ensure proper platform operations.

Additional Information
References:
Problem Resolution "12K/15K/E20K/E25K: SC POST results: Power On Selftest not run on last reset.
Technical Instruction "Sun Enterprise[TM] 12K/15K: EIS standard EEPROM settings"
Problem Resolution "Sun Fire[TM] 15K: Running diagnostics on System Controller"

Product
Sun Fire E25K Server
Sun Fire E20K Server
Sun Fire 15K Server
Sun Fire 12K Server

Seeprom, 15k, 12k, 20k, 25k
Previously Published As
88229

Change History
Date: 2010-04-26
User Name: Volkmar Grote 117021
Action: Reviewed for Content Team