Solution Type  Problem Resolution Sure

Solution  1007619.1 :   Sun Fire [TM] 15k (12k) system controller gives message WARNING: pcipsy0: spurious interrupt from ino 0x1c  


Related Items
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
210538


Applies to:

Sun Fire 12K Server
Sun Fire 15K Server
All Platforms

Symptoms

Sun Fire [TM] 15k (12k) system controller reports following error messages:

Mar 4 22:50:12 v4u-15ka-sc1 pcipsy: [ID 781074 kern.warning] WARNING: pcipsy0: spurious interrupt from ino 0x1c
Mar 4 22:50:12 v4u-15ka-sc1 pcipsy: [ID 548919 kern.info] su-0#0
Mar 4 22:50:12 v4u-15ka-sc1 pcipsy: [ID 100033 kern.info]

Cause

Check if a serial cable is connected to the System Controller and left disconnected on the other side. Leaving the cable disconnected this way can cause these errors.

This issue has been witnessed on Solaris [TM] 8 and Solaris [TM] 9.

It is documented in Bug ID 4966922.

Solution

  • Disconnect the serial cable from the System Controller.
Or:
  • Reconnect the other side of the serial cable to the terminal concentrator (if any) or Laptop.
This problem usually starts after a service action, such as sms upgrade or patch install.


system controller, 15k, 12k, sc, spurious, interrupt
Previously Published As 74664

Change History
Reviewed by ESG Content Team on 19 Nov 2009