Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1006728.1
Update Date:2011-01-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1006728.1 :   Connection to Nile proxy is down and could not be re-established, remote reporting aborted.  


Related Items
  • Sun Fire E25K Server
  •  
  • Solstice FTAM
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
209372


Applies to:

Sun Fire 12K Server
Sun Fire 15K Server
Sun Fire E20K Server
Sun Fire E25K Server
Solstice FTAM - Version: 9.0 and later    [Release: 9.0 and later]
All Platforms

Symptoms

Error messages like these appear after each "erd" event message:

Aug 15 07:32:39 2006 sc0-summer erd[3107]: [11900 ... CRIT MessageReportingService.cc 243] [VCM] Event: SF15000-800C-SP CSN: 310A4711 DomainID: A ADInfo: 1.VCM-DE.1 Time: Tue Aug 15 07:32:31 MEST 2006 Recommended-Action: Service action required
Aug 15 07:32:39 2006 sc0-summer erd[3107]: [11918 ... ERR RemoteReportingService.cc 237] EVENT-CLASS: list.suspects; Connection to Nile proxy is down and could not be re-established, remote reporting aborted.

The exact line numbers vary between SMS versions and patch levels.

Cause

erd is looking for a library (libsrsimapi.so.1) to log the event to SRS/NetConnect* but fails to find it, most likely because it was never installed.

Solution

This message is harmless.

The Nile proxy is a piece of software used to establish a safe connection from the customer's system to a site within Sun for remote system monitoring.
erd is looking for a library (libsrsimapi.so.1) to log the event to SRS/NetConnect* but fails to find it, most likely because it was never installed.

Relief/Workaround

If SRS/NetConnect* is installed and you still see these messages, please check the installation instructions for the package and SMS.


Additional Information
Please note that other Sun software may also use this library to report events to Sun.

* SRS/Netconnect infrastructure was decommissioned in May 2009 and was replaced by Solaris Tool Bundle.

Product
System Management Services 1.5 Software
Sun Fire E25K Server
Sun Fire E20K Server
Sun Fire 15K Server
Sun Fire 12K Server
Amazon 20/25 Phase 2 Hardware

Internal Comments
For Internal Use Only

A change request to remove these repeated messages from erd
had been filed and closed as "not worth fixing".
See escalation 1-19001626 and CR 6461946.

Information about the Nile project
sms, erd, srs, netconnect, nile

Previously Published As 86689

Change History
Date: 2006-08-25
User Name: 95826
Action: Approved
Comment: - ckecked change : ok
- no further edit required
Publishing
Product_uuid
6ce875f9-a63d-11d9-9adf-080020a9ed93|System Management Services 1.5 Software
d842dd03-059b-11d8-84cb-080020a9ed93|Sun Fire E25K Server
1404a2d3-059a-11d8-84cb-080020a9ed93|Sun Fire E20K Server
29e4659c-0a18-11d6-9fa1-e67bbc033df8|Sun Fire 15K Server
077fd4c5-df8f-4320-ad69-7d01603a674d|Sun Fire 12K Server
5bd95459-a08a-11d8-ab52-080020a9ed93|Amazon 20/25 Phase 2 Hardware

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback