Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1006728.1 : Connection to Nile proxy is down and could not be re-established, remote reporting aborted.
PreviouslyPublishedAs 209372
Applies to:Sun Fire 12K ServerSun Fire 15K Server Sun Fire E20K Server Sun Fire E25K Server Solstice FTAM - Version: 9.0 and later [Release: 9.0 and later] All Platforms SymptomsError messages like these appear after each "erd" event message:Aug 15 07:32:39 2006 sc0-summer erd[3107]: [11900 ... CRIT MessageReportingService.cc 243] [VCM] Event: SF15000-800C-SP CSN: 310A4711 DomainID: A ADInfo: 1.VCM-DE.1 Time: Tue Aug 15 07:32:31 MEST 2006 Recommended-Action: Service action required Aug 15 07:32:39 2006 sc0-summer erd[3107]: [11918 ... ERR RemoteReportingService.cc 237] EVENT-CLASS: list.suspects; Connection to Nile proxy is down and could not be re-established, remote reporting aborted. The exact line numbers vary between SMS versions and patch levels. Causeerd is looking for a library (libsrsimapi.so.1) to log the event to SRS/NetConnect* but fails to find it, most likely because it was never installed.SolutionThis message is harmless.The Nile proxy is a piece of software used to establish a safe connection from the customer's system to a site within Sun for remote system monitoring. Relief/Workaround If SRS/NetConnect* is installed and you still see these messages, please check the installation instructions for the package and SMS. Additional Information Please note that other Sun software may also use this library to report events to Sun. * SRS/Netconnect infrastructure was decommissioned in May 2009 and was replaced by Solaris Tool Bundle. Product System Management Services 1.5 Software Sun Fire E25K Server Sun Fire E20K Server Sun Fire 15K Server Sun Fire 12K Server Amazon 20/25 Phase 2 Hardware Internal Comments For Internal Use Only A change request to remove these repeated messages from erd had been filed and closed as "not worth fixing". See escalation 1-19001626 and CR 6461946.
Information about the Nile project
Previously Published As 86689 Date: 2006-08-25 User Name: 95826 Action: Approved Comment: - ckecked change : ok - no further edit required Publishing Product_uuid 6ce875f9-a63d-11d9-9adf-080020a9ed93|System Management Services 1.5 Software d842dd03-059b-11d8-84cb-080020a9ed93|Sun Fire E25K Server 1404a2d3-059a-11d8-84cb-080020a9ed93|Sun Fire E20K Server 29e4659c-0a18-11d6-9fa1-e67bbc033df8|Sun Fire 15K Server 077fd4c5-df8f-4320-ad69-7d01603a674d|Sun Fire 12K Server 5bd95459-a08a-11d8-ab52-080020a9ed93|Amazon 20/25 Phase 2 Hardware Attachments This solution has no attachment |
||||||||||||
|