Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1002642.1
Update Date:2011-05-12
Keywords:

Solution Type  Problem Resolution Sure

Solution  1002642.1 :   SMS Failover is disabled due to I2 network failure running on Solaris[TM] 10 Operating System with patch 122608-03 installed  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
203643


Applies to:

Sun Fire E20K Server
Sun Fire E25K Server
Sun Fire 12K Server
Sun Fire 15K Server
All Platforms

Symptoms

SMS (System Management Services) Failover is disabled due to I2 network failure.

An example of the showfailover output and linkup/linkdown messages from the Main SC:

sms% showfailover -v
SC Failover Status:     FAILED
Status of Shared Memory:
HASRAM (CSB at CS0):     ................................Powered Off
HASRAM (CSB at CS1):     ................................Powered Off

Status of sc0:
Role:                    .......................................MAIN
SMS Daemons:             .......................................Good
System Clock:            .......................................Good
Private I2 Network:      .....................................FAILED
Private HASRAM Network:  .....................................FAILED
Public Network:          .................................NOT TESTED
System Memory:           ........................................4.7%
Disk Status:             ........................................1.4%
Console Bus Status:      .................................NOT TESTED

** Unable to retrieve status from remote SC.

Messages logged:

eri: SUNW,eri1 : 100 Mbps full duplex link up
Apr 21 18:34:47 sc0 eri: SUNW,eri2 : No response from Ethernet network : Link down -- cable problem?
Apr 21 18:34:48 sc0 eri: SUNW,eri2 : 100 Mbps full duplex link up
Apr 21 18:34:57 sc0 eri: SUNW,eri1 : 100 Mbps full duplex link up
Apr 21 18:35:07 sc0 eri: SUNW,eri2 : 100 Mbps full duplex link up
Apr 21 18:35:15 sc0 eri: SUNW,eri1 : No response from Ethernet network : Link down -- cable problem?


Changes

Patch ID 122608-03 was installed on  Solaris[TM] 10 Operating System.

It is very likely that systems shipped in the first quarter of 2007 were shipped with this patch and may be configured with ipfiltering enabled in a generic manner. As a result, SMS failover would be disabled due to the I2 network failures at time of install for the affected systems.

Cause

This SUNWjass patch enables ipfiltering. With ipfiltering enabled in a generic way, all communications between SCs on the I2 network is blocked. Hence, I2 network fails, and failover is disabled.
Historically, ipfiltering has never been enabled on the SCs (even with Secure by Default installations). Therefore, all SMS testing has been executed with ipfiltering disabled.

Solution

A fix for Bug ID 6537623 has been implemented in 122608-05.

The text from workaround section of the bug is included for cases where a patch installation is not immediately possible.

Relief/Workaround

1) Change /opt/SUNWjass/Files/etc/ipf/ipf.conf-15k_sc *AND*
/etc/ipf/ipf.conf

by adding ALL 4 "pass in" lines as follows:
# Allow connections with the other SC (scman1, aka I2 network)
# This includes the Zoe daemon (55/tcp) used for SC failover communication.
pass in on scman1 proto tcp from any to any keep state
pass in on scman1 proto udp from any to any keep state
#
# Allow connections with the domains (scman0, aka I1 network)
# (This is *TEMPORARY* until the specific ports required for sc/domain communication
# have been verified--see Suggested Fix for 6537623.)
pass in on scman0 proto tcp from any to any keep state
pass in on scman0 proto udp from any to any keep state
After changing you MUST reboot OR restart the ipfilter SMF service (svcadm restart ipfilter).

2) Disable ipfiltering (ipfilter.fin) by commenting out ipfilter.fin in file
/opt/SUNWjass/Drivers/sunfire_15k_sc-hardening.driver. Then undo and reapply SST:
/opt/SUNWjass/bin/jass-execute -u
shutdown -y -i6
/opt/SUNWjass/bin/jass-execute -d sunfire_15k_sc-secure.driver
Then reboot.

3) Disable the ipfilter service in Solaris if enabled:
# svcadm disable ipfilter
# svcs ipfilter
STATE          STIME    FMRI
disabled        7:42:05 svc:/network/ipfilter:default

SMS, S10, Solaris 10, failover, ipfilter, SST, I2 network, FAILED
Previously Published As 89167

Change History

Date: 2007-12-04
User Name: 97961
Action: Approved
Comment: Publishing. No further edits required.
Version: 7

Date: 2007-12-04
User Name: 97961
Action: Accept
Comment:
Version: 0

Date: 2007-12-04
User Name: 18410
Action: Approved
Comment: Checked document for the most recent change - it's now ready to be published