Solution Type Problem Resolution Sure Solution 1006217.1 : Sun Fire[TM] System Controller: Warning Message Appears After the CP1500 Board Replacement
PreviouslyPublishedAs 208701
Applies to:Sun Fire 15K Server - Version: Not ApplicableSun Fire 12K Server - Version: Not Applicable and later [Release: N/A and later] All Platforms SymptomsThe following is the Sun Fire[TM] 15K System Controller warning message that appears after a CP1500 board replacement:May 20 12:30:48 sc0 root: Warning: Unable to detect gchip in system configuration. The S99sms command should only be executed on a Sun Fire 15K System Controller. CauseThe new SC doesn't have the proper firmware loaded.SolutionThe resolution is to do the following "flashupdate":root@sc0 # su - sms-svc sc0:sms-svc:1> cd /opt/SUNWSMS/firmware sc0:sms-svc:2> ls SCOBPimg.di nSSCPOST.di oSSCPOST.di sc0:sms-svc:3> flashupdate -f SCOBPimg.di sc0/fp0 Unable to determine local SC number. Only the local System Control Fproms can be updated. Do you wish to continue? (yes/no)? yes Current System Controller FPROM Information =========================================== ERROR: Invalid FPROM segment at offset 0. SC Flash Image Information ========================== Name: SSCOBP-dropins, Version: 1.3 Size: 144, Check Sum: 55375 Date Flashed: 03/09/04 Date Created: 03/09/04 Do you wish to update the SC User FPROM (yes/no)? yes Update SC at Local SC, FPROM 0 : Erasing... Done. Writing and verifying ... Done. Internal Comments This procedure has been performed successfully on a customer's site. References<NOTE:1000816.1> - Firmware upgrade required when replacing the CP1500 CPU on the System Controller of a Sun Fire 15K system.<NOTE:1001900.1> - Sun Fire[TM] 12K/15K: Checking and Updating SC Firmware(FW) Guidelines <NOTE:1010734.1> - SunFire[TM] 12K/15K/E20K/E25K servers: Installing/Replacing a CP2140 (Othello+) in a SunFire 12K/15K/20K/25K server Attachments This solution has no attachment |
||||||||||||
|