Solution Type Problem Resolution Sure Solution 1005038.1 : Sun Fire[TM] 12K/15K/E20K/E25K: Domain Reboots if the Open Boot PROM Boot Device Is Incorrect
PreviouslyPublishedAs 207089
Applies to:Sun Fire 12K ServerSun Fire 15K Server Sun Fire E20K Server Sun Fire E25K Server All Platforms ***Checked for relevance on 23-Apr-2011*** SymptomsA domain on a Sun Fire[TM] 12K/15K/E25K platform reboots if the domain cannot boot off the Open Boot PROM boot device, either because it is set incorrectly or because of a hardware failure.CauseFor example, if a user modifies the boot device of a domain incorrectly and then tries to boot the domain, the domain will be rebooted automatically. The user is then disconnected from the domain console. Messages similar to the following will appear on the console:
$SMSVAR/SMS/adm/--->domain_id<---/messages: Feb 28 10:32:40 2003 xc9p13-sc1 dsmd[7207]-M(): [2536 1359068189896205 NOTICE DomainsPatrol.cc 664] Reset domain M request received, restarting domain. Feb 28 10:34:35 2003 xc9p13-sc1 dsmd[7207]-M(): [2537 1359183873470286 NOTICE DomainsPatrol.cc 747] Domain M OBP failed, rebooting domain. Feb 28 10:34:35 2003 xc9p13-sc1 dsmd[7207]-M(): [0 1359183874528188 NOTICE SysControl.cc 485] Since domain failure occurred at OBP, set boot command to SolutionThis is a feature of the Sun System Management Software (SMS) and the system is performing as designed. It is actually the domain status monitoring daemon (DSMD) controlled by SMS that initiates the rebootaction. DSMD has no way to determine whether the cause is due to a user's typographical error or due to a true error. For example, the error reported by Open Boot PROM could be a true error for those occasions when the boot disk is powered down. Internal Comments This is behavior will not be changed. See internal Bug ID 4825660 See also <Document 1004721.1> Can't locate boot device, OBP failed, rebooting domain, 12K, 15K, E20K, E25K, boot-device, incorrect, The dxs disconnected, starcat Previously Published As 76798 Attachments This solution has no attachment |
||||||||||||
|