Solution Type Problem Resolution Sure Solution 1017727.1 : System Management Services (SMS) 1.3 or older: flashupdate unable to flash boards with 5.19.X or newer
PreviouslyPublishedAs 228936
Applies to:Sun Fire E25K ServerSun Fire 12K Server Sun Fire 15K Server Sun Fire E20K Server All Platforms SymptomsSystems running System Management Services(SMS) 1.3 or older software, are unable to flashupdate new system boards that have 5.19.X or newer firmware pre-installed.ChangesThe version of flashupdate that comes with SMS 1.3 or older, can only handle images less than 1M in size. If a system is running SMS 1.3 then it should be using lpost 5.14.X.CauseNew boards, or replacement boards from the RSLs, will be unuseable if they have the latest firmware(5.20.X) installed.Update: 23-June-2008: Sustaining support for SMS 1.3 was discontinued October 5, 2005. So SMS 1.3 should not be used anymore. Customers still using SMS versions less then 1.6 are kindly urged to upgrade asap. The workaround in this document should not been seen as support for SMS 1.3 and should only be used to avoid critical customer situations. SolutionThe workaround and solution, is to upgrade to 1.6.A special flashupdate binary is available from Sun only to relieve critical customer situations and the action plan need to include a planning for SMS upgrade to a supported version. This flashupdate binary ignores the read errors and will flash successfully if you answer yes to the question. Here is an example: sms-svc:36> ./flashupdate -f /opt/SUNWSMS/hostobjs/sgcpu.flash SB7 Current System Board FPROM Information CPU at SB7, FPROM 1: Flash Image Information Do you wish to update the FPROM (yes/no)? yes Notes: Prior to downloading the new flashupdate program make a backup copy of the existing flashupdate program. This is for your protection only. ***DO NOT OVERWRITE THE FLASHUPDATE program*** # cp /opt/SUNWSMS/bin/flashupdate /opt/SUNWSMS/bin/flashupdate.orig Relief/Workaround 1) Upgrade SMS to version SMS 1.5 or SMS 1.6 This is the preferred method. 2) Use a different starcat platform running SMS 1.4.1, SMS 1.5 or SMS 1.6 to flash the boards prior to inserting them into the SMS 1.3 platform. SMS 1.3 can downgrade from 5.18.x and 5.17.x . So these can be use as interim versions. 3) Use a Sun Fire[TM] E6900/E4900/6800/4810/4800/3800 server to flash the boards prior to inserting them into the SMS 1.3 platform. SMS 1.3 can downgrade from 5.18.x and 5.17.x . So these can be use as interim versions. Additional Information System Management Services (SMS) 1.3 or older: flashupdate unable to flash boards with 5.19.X or newer The problem is fixed in SMS 1.4, so will exist in all versions of SMS prior to 1.4. At the time of writing of this document, SMS 1.5 and SMS 1.6 are the supported SMS versions. For more information on SMS releases and firmware versions, see: For more information on supported SMS versions see: www.sun.com: Sun Fire System Management Services (SMS) Product Sun Fire E25K Server Sun Fire E20K Server Sun Fire 15K Server Sun Fire 12K Server Internal Comments System Management Services (SMS) 1.3 or older
The internal link to the InfoDoc:
The flashupdate binary can be found at:
See Bug: CR 4818465 Need to support images > 1MB Attachments This solution has no attachment |
||||||||||||
|