Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire V880 - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Backplane/Centerplane
Option # Manufacturing
Part #
Description Previous
Part #
X6751A [S] 595-6213 Storage Expansion Kit, includes 1 of the following backplanes and 6 of the following disks: n/a
  • 6 Slot FC Base/Expansion Backplane
501-5993 [F]
  • 540-4525 [F]
  • 36.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks:
n/a
    • 340-6640
    • Plate
n/a
    • 340-7269
    • Plate,
n/a
    • Seagate ST336704FC [ST336704FSUN36G]
      (36.4GB - 10000 RPM - FC-AL Disk)
n/a
    • Seagate ST336605FC [ST336605FSUN36G]
      (36.4GB - 10000 RPM - FC-AL Disk)
n/a
    • Seagate ST336607FC [ST336607FSUN36G]
      (36.4GB - 10000 RPM - FC-AL Disk)
n/a
    • 1" SPUD Bracket,
n/a
X6756A [S] 595-6347 2 Storage Expansion Kit, includes 1 of the following backplanes and 6 of the following disks: n/a
  • 6 Slot FC Base/Expansion Backplane
501-5993 [F]
  • 540-5408 1 [F]
  • 73.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks:
n/a
    • 340-6640
    • Plate
n/a
    • 340-7269
    • Plate,
n/a
    • Seagate ST373405FC [ST373405FSUN72G]
      (73.4GB - 10000 RPM - FC-AL Disk)
n/a
    • Fujitsu MAN3735FC [MAN3735F SUN72G]
      (73.4GB - 10000 RPM - FC-AL Disk)
n/a
    • Seagate ST373307FC [ST373307FSUN72G]
      (73.4GB - 10000 RPM - FC-AL Disk)
n/a
    • Fujitsu MAP3735FC [MAP3735F SUN72G]
      (73.4GB - 10000 RPM - FC-AL Disk)
n/a
    • Hitachi DK32EJ-72FC [DK32EJ72FSUN72G]
      (73.4GB - 10000 RPM - FC-AL Disk)
n/a
    • Seagate ST373207FC [ST373207FSUN72G]
      (73.4GB - 10000 RPM - FC-AL Disk)
n/a
    • Fujitsu MAT3073FC [MAT3073F SUN72G]
      (73.4GB - 10000 RPM - FC-AL Disk)
n/a
    • Hitachi HUS1073FA [HUS1073FASUN72G]
      (73.4GB - 10000 RPM - FC-AL Disk)
n/a
    • 1" SPUD Bracket,
n/a
X6858A [S] 595-7103 Storage Expansion Kit, includes 1 backplane and 6 of the following disks: n/a
  • 6 Slot FC Base/Expansion Backplane
501-5993 [F]
  • 540-5459 4 [F]
  • 146GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks:
n/a
    • 340-6640
    • Plate
n/a
    • 340-7269
    • Plate,
n/a
    • Seagate ST3146807FC [ST314680FSUN146G]
      (146GB - 10000 RPM - FC-AL Disk)
n/a
    • Fujitsu MAP3147FC [MAP3147F SUN146G]
      (146.8GB - 10000 RPM - FC-AL Disk)
n/a
    • Hitachi DK32EJ-14FC [DK32EJ14FSUN146G]
      (146GB - 10000 RPM - FC-AL Disk)
n/a
    • Seagate ST3146707FC [ST314670FSUN146G]
      (146GB - 10000 RPM - FC-AL Disk)
n/a
    • Fujitsu MAT3147FC [MAT3147F SUN146G]
      (146GB - 10000 RPM - FC-AL Disk)
n/a
    • Hitachi HUS1014FA [HUS1014FASUN146G]
      (146GB - 10000 RPM - FC-AL Disk)
n/a
    • Fujitsu MAW3147FC [MAW3147FCSUN146G]
      (146GB - 10000 RPM - FC-AL Disk),
n/a
    • Hitachi HUS1014FA [HUS1014FASUN146G]
      (146GB - 10000 RPM - FC-AL Disk),
n/a
    • Seagate ST3146707FC [ST314670FSUN146G]
      (146GB - 10000 RPM - FC-AL Disk),
n/a
    • 1" SPUD Bracket,
n/a
n/a 230-1697 3 nylon washers to insulate screws from FC Disk Backplane, included with X6751A and X6756A, required n/a
n/a 501-5993 [F] 6 Slot FC Base/Expansion Backplane n/a
n/a 501-6665 [F] 6 Slot FC Base/Expansion Backplane 501-5993 [F]
1 Effective 27-Jan-2006, this assembly was replaced by 540-6604 in option X6805A.
2 Previously, 595-6347 consisted of 1 × 501-6665 and 6 × 540-4905 disks.
3 Effective 27-Jan-2006, this assembly ships with option XRA-FC1CB-146G10K.
4 Effective 27-Jan-2006, this assembly was replaced by 540-6605 in option XRA-FC1CB-146G10K.
NOTE: Some Sun Fire V880s may have the following two parts installed:
NOTE: Supported disk backplane cabling diagrams
Boot PROM
Socket Manufacturing
Part #
Patch
U3007 525-1793 119231
Cables
Option # Manufacturing
Part #
Description Previous
Part #
X311L Price Localized Power Cord Kit - North America/Asia,
180-1097 [C] IEC 320 C13 to NEMA 5-15P - 15A/125V 2.5M Black, n/a
X312L Localized Power Cord Kit - Continental Europe,
180-1993 [C] IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, n/a
X314L Localized Power Cord Kit - Swiss,
180-1994 [C] IEC 320 C13 to SEV 1011 - 10A/250V 2.5M Black, n/a
X317L Localized Power Cord Kit - U.K.,
180-1997 [C] IEC 320 C13 to BS 1363 - 10A/250V 2.5M Black, n/a
X320A Price Localized Power Cord Kit - North America/Asia,
180-2164 [C] IEC 320 C13 to NEMA 6-15P - 10A/250V 2.0M Black, 530-1351 [C]
X383L Localized Power Cord Kit - Danish,
180-1995 [C] IEC 320 C13 to Asfnit 107 - 10A/250V 2.5M Black, 530-1819 [C]
X384L Localized Power Cord Kit - Italian,
180-1996 [C] IEC 320 C13 to CEI 23-16/VII - 10A/250V 2.5M Black, n/a
X386L Localized Power Cord Kit - Australian,
180-1998 [C] [S] IEC 320 C13 to AS 3112 - 10A/250V 2.5M Black, n/a
X9715A 537-1020 [F] Fibre Optical Cable SC/SC, 5M n/a
X973A 537-1004 [F] Fibre Channel Optical Cable 50/125 Multimode, 2M n/a
X978A 537-1006 [F] Fibre Channel Optical Cable 50/125 Multimode, 15M n/a
X985A 530-1869 [F] Serial Port Adapter (Y-Splitter) Cable, 50 cm n/a
X3830A [S] 530-2454 [F] External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 4M n/a
X3831A [S] 530-2455 [F] External SCSI Cable (Drive to Host HBA), HD68 to VHDC, 10M n/a
X3832A [S] 530-2453 [F] External SCSI Cable, HD68 to VHDCI, 2M n/a
X3872A [S] 130-3034 [F] HD15F to DB13W3M Adapter n/a
X470A [S] 530-2357 [F] Video Connector Adapter, 13W3F to HD15M n/a
X6755A [S] 530-3056 [F] Internal Loop B cable n/a
X913A [S] 130-4332 FastWide to Narrow SCSI Adapter, L n/a
n/a 530-1351 [C] IEC 320 C13 to NEMA 6-15 - 10A/250V 2.0M Black, n/a
n/a 530-1819 [C] Localized Power Cord Kit - Danish n/a
n/a 530-4249 [F] Dual FC-AL PCI Board Loop B Cable, 530-3732 [F]
Communication
Option # Manufacturing
Part #
Description Previous
Part #
X1074A 5 [S] 370-3868 [F] SCI Adapter (SCI/P) n/a
X1133A [S] 375-0130 [F] Crypto Accelerator I n/a
X1155A [S] 370-2728 [F] High Speed Serial Interface PCI (HSI/P) 2.0 n/a
X1157A [S] 501-3028 [F] SunATM-155/MFiber PCI 4.0 n/a
X1158A [S] 501-3027 [F] SunATM-155/UTP PCI 4.0 n/a
X1159A [S] 501-3029 [F] SunATM-622/MFiber PCI 4.0 n/a
X2156A [S] 375-0100 [F] Serial Asynchronous Interface PCI (SAI/P) 3.0 n/a
X3895A [S] 370-3922 [F] Cluster 4 port SCI switch, Dolphin Model D515 n/a
X3901A [S] 530-2869 [F] Cluster SCI Cable, 2M n/a
X3903A [S] 530-2871 [F] Cluster SCI Cable, 7.5M n/a
X3904A [S] 530-2872 [F] Cluster SCI Cable, 10M n/a
X4011A [S] 501-6039 [F] Crypto Accelerator 4000 UTP (copper) n/a
X4012A [S] 501-6040 [F] Crypto Accelerator 4000 MMF (fiber) n/a
X4111A [S] 501-6039 [F] Crypto Accelerator 4000 UTP (copper) n/a
X4112A [S] 501-6040 [F] Crypto Accelerator 4000 MMF (fiber) n/a
X4810A 6 [S] 540-4721 [F] Sun OC48 Packet Over Sonet n/a
X4812A [S] 540-5207 [F] Sun OC48 Packet Over Sonet SRP Cable Kit n/a
  • 530-2995
  • Cable, External Copper, SRP Data, 50cm
n/a
  • 530-2996
  • Cable, Internal Coaxial, SRP Clock
n/a
X6762A [S] 375-3089 [F] Crypto Accelerator 1000 n/a
n/a 501-5856 [F] Remote System Control (RSC2) Board n/a
n/a 501-6767 [F] Advanced Lights Out Manager Plus Card n/a
5 This option requires a pair of SCI cables: order two of option X3901A, X3903A, or X3904A. Option X3895A is needed for more than two nodes.
6 Maximum of two X4810A cards per V880 server supported. X4810A must be installed in 66MHz PCI slot only.
Disks
Option # Manufacturing
Part #
Description Previous
Part #
XRA-FC1CB-146G10K 540-6605 11 [F] 146GB - 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, 540-5459 10 [F]
  • 341-1986
  • Plate,
n/a
  • Fujitsu MAW3147FC [MAW3147FCSUN146G]
    (146GB - 10000 RPM - FC-AL Disk),
n/a
  • Hitachi HUS1014FA [HUS1014FASUN146G]
    (146GB - 10000 RPM - FC-AL Disk),
n/a
  • Seagate ST3146707FC [ST314670FSUN146G]
    (146GB - 10000 RPM - FC-AL Disk),
n/a
  • 1" SPUD Bracket,
n/a
X6724A [S] 540-4525 [F] 36.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST336704FC [ST336704FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST336605FC [ST336605FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST336607FC [ST336607FSUN36G]
    (36.4GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
X6742A [S] 540-4905 [F] 73.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST373405FC [ST373405FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST373307FC [ST373307FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST373207FC [ST373207FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
X6805A [S] 540-6604 13 [F] 73.4GB - 10000 RPM, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks, 540-5408 12 [F]
  • 341-1986
  • Plate,
n/a
  • Fujitsu MAW3073FC [MAW3073FCSUN73G]
    (73.4GB - 10000 RPM - FC-AL Disk),
n/a
  • Hitachi HUS1073FA [HUS1073FASUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk),
n/a
  • Seagate ST373207FC [ST373207FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk),
n/a
  • 1" SPUD Bracket,
n/a
n/a 540-5408 7 [F] 73.4GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST373405FC [ST373405FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAN3735FC [MAN3735F SUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST373307FC [ST373307FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAP3735FC [MAP3735F SUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Hitachi DK32EJ-72FC [DK32EJ72FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST373207FC [ST373207FSUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAT3073FC [MAT3073F SUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • Hitachi HUS1073FA [HUS1073FASUN72G]
    (73.4GB - 10000 RPM - FC-AL Disk)
n/a
  • 1" SPUD Bracket,
n/a
n/a 540-5459 9 [F] 146GB - 10000 RPM FC-AL, Disk Assembly with 1 bracket, 1 of the following plates, and 1 of the following disks: n/a
  • 340-6640
  • Plate
n/a
  • 340-7269
  • Plate,
n/a
  • Seagate ST3146807FC [ST314680FSUN146G]
    (146GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAP3147FC [MAP3147F SUN146G]
    (146.8GB - 10000 RPM - FC-AL Disk)
n/a
  • Hitachi DK32EJ-14FC [DK32EJ14FSUN146G]
    (146GB - 10000 RPM - FC-AL Disk)
n/a
  • Seagate ST3146707FC [ST314670FSUN146G]
    (146GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAT3147FC [MAT3147F SUN146G]
    (146GB - 10000 RPM - FC-AL Disk)
n/a
  • Hitachi HUS1014FA [HUS1014FASUN146G]
    (146GB - 10000 RPM - FC-AL Disk)
n/a
  • Fujitsu MAW3147FC [MAW3147FCSUN146G]
    (146GB - 10000 RPM - FC-AL Disk),
n/a
  • Hitachi HUS1014FA [HUS1014FASUN146G]
    (146GB - 10000 RPM - FC-AL Disk),
n/a
  • Seagate ST3146707FC [ST314670FSUN146G]
    (146GB - 10000 RPM - FC-AL Disk),
n/a
  • 1" SPUD Bracket,
n/a
7 Effective 27-Jan-2006, this assembly was replaced by 540-6604 in option X6805A.
8 Effective 27-Jan-2006, this assembly ships with option XRA-FC1CB-146G10K.
9 Effective 27-Jan-2006, this assembly was replaced by 540-6605 in option XRA-FC1CB-146G10K.
10 Effective 27-Jan-2006, this assembly was replaced by 540-6605 in option XRA-FC1CB-146G10K.
11 Effective 27-Jan-2006, this assembly ships with option XRA-FC1CB-146G10K.
12 Effective 27-Jan-2006, this assembly was replaced by 540-6604 in option X6805A.
13 Effective 27-Jan-2006, this assembly ships with option X6805A.
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
X5558A Price 375-3301 [C] 10Gb/sec XFP Optical Transceiver Short Range (SR), L n/a
X5560A-Z Price 375-3495 [F] 10Gb/sec XFP Optical Transceiver Long Range (LR), n/a
4455A [S] 10Gb PCI-X Ethernet Adapter w/ Transceiver (low-profile brackets)
375-3301 [C] 10Gb/sec XFP Optical Transceiver Short Range (SR), L n/a
501-7163 10Gb/sec PCI-X Ethernet Adapter n/a
  • 370-7792
  • Bracket Low-Profile 10Gb PCI-X Ethernet,
n/a
4455A-4 [S] 375-3301 [C] 10Gb/sec XFP Optical Transceiver Short Range (SR), L n/a
501-7414 10Gb/sec PCI-X Ethernet Adapter, n/a
  • 370-7792
  • Bracket Low-Profile 10Gb PCI-X Ethernet,
n/a
4466A [S] 375-3361 [C] XFP Optical PCI-X Transceiver Single Mode Fibre, L n/a
501-7414 10Gb/sec PCI-X Ethernet Adapter, n/a
  • 370-7792
  • Bracket Low-Profile 10Gb PCI-X Ethernet,
n/a
5544A [S] 10Gb PCI-X Ethernet Adapter w/ Transceiver (standard brackets)
375-3301 [C] 10Gb/sec XFP Optical Transceiver Short Range (SR), L n/a
501-7036 [C] 10Gb/sec PCI-X Ethernet Adapter n/a
  • 370-7665
  • Bracket Standard 10Gb PCI-X Ethernet,
n/a
5544A-4 [S] 375-3301 [C] 10Gb/sec XFP Optical Transceiver Short Range (SR), L n/a
501-7413 [C] 10Gb PCI-X Ethernet Adapter, n/a
  • 370-7665
  • Bracket Standard 10Gb PCI-X Ethernet,
n/a
  • 370-7792
  • Bracket Low-Profile 10Gb PCI-X Ethernet,
n/a
6644A [S] 375-3361 [C] XFP Optical PCI-X Transceiver Single Mode Fibre, L n/a
501-7413 [C] 10Gb PCI-X Ethernet Adapter, n/a
  • 370-7665
  • Bracket Standard 10Gb PCI-X Ethernet,
n/a
  • 370-7792
  • Bracket Low-Profile 10Gb PCI-X Ethernet,
n/a
X1033A [S] 501-5019 [F] Sun FastEthernet PCI Adapter (FE/P) 2.0 n/a
X1034A [S] 501-5406 [F] Quad FastEthernet PCI (QFE/P) n/a
X1141A [S] 501-4373 [F] Gigabit Ethernet PCI (GBE/P) 2.0 n/a
X1150A [S] 501-5902 [F] Sun GigaSwift Ethernet UTP (Copper) n/a
X1151A [S] 501-5524 [F] Sun GigaSwift Ethernet MMF (Fiber) n/a
X3150A [S] 501-5902 [F] Sun GigaSwift Ethernet UTP (Copper) n/a
X3151A [S] 501-5524 [F] Sun GigaSwift Ethernet MMF (Fiber) n/a
X4150A [S] 501-6719 [F] GigaSwift Ethernet UTP (GCS) n/a
X4151A [S] 501-6762 [F] GigaSwift Ethernet MMF (GFS) n/a
X4444A 14 [S] 501-6522 [F] Quad GigaSwift Ethernet UTP (QGE) n/a
X4445A [S] 501-6738 [F] Quad GigaSwift PCI-X Ethernet (QGE-X), n/a
X5544A 15 [S] 10Gb PCI-X Ethernet Adapter, no transceiver
370-7792 Bracket Low-Profile 10Gb PCI-X Ethernet, n/a
501-7036 [C] 10Gb/sec PCI-X Ethernet Adapter n/a
  • 370-7665
  • Bracket Standard 10Gb PCI-X Ethernet,
n/a
X5544A-4 [S] 10Gb PCI-X Ethernet Adapter, no transceiver,
501-7413 [C] 10Gb PCI-X Ethernet Adapter, n/a
  • 370-7665
  • Bracket Standard 10Gb PCI-X Ethernet,
n/a
  • 370-7792
  • Bracket Low-Profile 10Gb PCI-X Ethernet,
n/a
X5559A [S] 375-3361 [C] XFP Optical PCI-X Transceiver Single Mode Fibre, L n/a
14 If replacing X4444A with X4445A (same driver but different chip set), a reconfigure boot is required. See Problem article 1003454.1.
15 Standard bracket 370-7665 is installed. Low-profile bracket 370-7792 is included. Order Option 4455A for factory integration.
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 540-3614 [F] CPU Fan Tray n/a
n/a 540-3615 [F] PCI I/O Fan Tray n/a
n/a 540-4025 [F] 80MM Motherboard Fan Tray n/a
Fibre Channel
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCI1FC-QF4 Price 375-3354 [F] 4Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI2FC-QF4 Price 375-3294 [F] 4Gb PCI-X Dual FC Host Adapter, n/a
SG-XPCI1FC-EM2 [S] 375-3304 [F] 2Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI1FC-JF2 [S] 375-3156 [F] JNI 2Gb PCI Single FC Host Adapter n/a
SG-XPCI1FC-QF2 [S] 375-3102 [F] 2Gb PCI Single FC Host Adapter n/a
SG-XPCI1FC-QL2 [S] 375-3383 [F] 2Gb PCI-X Single FC Host Adapter, n/a
SG-XPCI2FC-EM2 [S] 375-3305 [F] 2Gb PCI-X Dual FC Host Adapter, n/a
SG-XPCI2FC-JF2 [S] 375-3157 [F] JNI 2Gb PCI Dual FC Host Adapter n/a
SG-XPCI2FC-QF2 [S] 375-3108 [F] 2Gb PCI/PCI-X Dual FC Host Adapter n/a
  • 240-4839
  • Low Profile Bracket,
n/a
SG-XPCI2FC-QF2-Z [S] 375-3363 [F] 2Gb PCI/PCI-X Dual FC Host Adapter, n/a
  • 240-4839
  • Low Profile Bracket,
n/a
X6727A [S] 375-3030 [F] PCI Dual FC Host Adapter+, L n/a
X6767A 16 [S] 375-3102 [F] 2Gb PCI Single FC Host Adapter n/a
X6768A 17 [S] 375-3108 [F] 2Gb PCI/PCI-X Dual FC Host Adapter n/a
  • 240-4839
  • Low Profile Bracket,
n/a
X6799A [S] 375-3019 18 [F] PCI Single FC Host Adapter n/a
16 X6767A changed to SG-XPCI1FC-QF2 in July 2003
17 X6768A changed to SG-XPCI2FC-QF2 in July 2003
18 375-3019 with SC connector is no longer available. The substitute adapter uses a smaller LC connector.
NOTE: X6727A is the only FC card that supports internal multipathing. If a separate, second FC loop is desired, an X6755A internal cable (530-3056) is required.
Graphics
Option # Manufacturing
Part #
Description Previous
Part #
X1089A [S] 370-4072 [F] SunVideo Plus n/a
X3668A [S] 370-3753 [F] PGX32 8/24-Bit Color Frame Buffer n/a
X3684A 19 20 [S] 375-3052 [F] Expert3D Lite PCI Frame Buffer n/a
X3685A 21 [S] 375-3069 [F] XVR-500 Graphics Accelerator n/a
X3768A [S] 370-4362 [F] PGX64 8/24-Bit Color Frame Buffer n/a
X3769A [S] 375-3126 [F] XVR-100 Graphics Accelerator (32MB) n/a
X3770A [S] 375-3181 [F] XVR-100 Graphics Accelerator (64MB) n/a
X3780A [S] 375-3153 [F] XVR-600 Graphics Accelerator n/a
X6091AP [S] 595-6777 Sun Fire V880 to Sun Fire V880z Upgrade Kit n/a
X7296A [S] 375-3290 22 [F] XVR-100 Graphics Accelerator (64MB), n/a
19 If X3684A is installed in a 66MHz PCI slot, the other 66MHz PCI slot must remain empty.
20 The X3684A graphics accelerator requires the 501-6524 or 501-5142-12 or higher I/O board and is not supported in Sun Fire V880 systems shipped with 750MHz USIII CPUs.
21 The X3684A and X3685A graphics accelerators require the 501-6524 or 501-5142-12 or higher I/O board and are not supported in Sun Fire V880 systems shipped with 750MHz USIII CPUs.
22 Refer to FAB article 1001156.1> fuzzy or blurry video with the XVR-100 Graphics Accelerator.
I/O
Option # Manufacturing
Part #
Description Previous
Part #
n/a 501-5142 [F] I/O Board n/a
  • IDPROM, L
n/a
n/a 501-6524 [F] I/O Board n/a
  • IDPROM, L
n/a
Memory
Option # Manufacturing
Part #
Description Previous
Part #
X7056A 28 4 GB (4 × 1GB SDRAM DIMMs)
501-7386 [F] 1GB SDRAM DIMM, L 501-6109 [F]
X7050A 29 [S] 512MB (4 × 128MB SDRAM DIMMs)
501-4489 [F] 128MB SDRAM DIMM n/a
X7051A [S] 2 GB (4 × 512MB SDRAM DIMMs)
501-7385 [F] 512MB SDRAM DIMM, L 501-5030 [F] 
X7051A-Z [S] 2 GB (4 × 512MB SDRAM DIMMs), L
501-7385 [F] 512MB SDRAM DIMM, L 501-5030 [F] 
X7053A [S] 1 GB (4 × 256MB SDRAM DIMMs)
501-5401 [F] 256MB SDRAM DIMM 540-5084
X7056A-Z [S] 4 GB (4 × 1GB SDRAM DIMMs), L
501-7386 [F] 1GB SDRAM DIMM, L 501-6109 [F]
n/a 501-5030 [F] 512MB SDRAM DIMM 540-5085
n/a 501-6109 [F] 1GB SDRAM DIMM n/a
n/a 540-5086 [F] 1GB SDRAM DIMM n/a
n/a F511-1030 24 [F] Package of 25 × 512MB SDRAM DIMMs n/a
  • 512MB SDRAM DIMM, L
501-5030 [F] 
n/a F511-1031 26 [F] Package of 25 × 1GB SDRAM DIMMs n/a
  • 1GB SDRAM DIMM, L
501-6109 [F]
24 See FAB article1000920 (formerly 201233) for details.
26 See FAB article1000920.1 (formerly 201233) for details.
28 1GB DIMMs are not supported on 750MHz CPU/Memory boards.
29 Only supported with 750MHz CPUs
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-1353 [F] Power Supply n/a
n/a 375-0071 [F] Power Distribution Board n/a
Rack
Option # Manufacturing
Part #
Description Previous
Part #
SR9-XKL038A-IP 595-6712 Sun Rack 900, Empty X-Option Rack without Power, n/a
X4347A 540-4687 Sun Fire Cabinet Expansion Kit n/a
SF-XCAB [S] 540-4613 Sun Fire Cabinet n/a
SG-XARY030A [S] 595-4706 72 inch Sun StorEdge Expansion Cabinet n/a
X9628A [S] 595-5801 Rack Mount Kit for 72 inch Sun StorEdge Expansion Cabinet and Sun Fire Cabinet n/a
X9638A [S] 595-6879 Rackmount Kit for Sun Rack 900 n/a
X9818A [S] 595-4999 72 inch StorEdge Expansion Cabinet Front Door Kit n/a
Removable Media
Option # Manufacturing
Part #
Description Previous
Part #
SG-XMEDDAT72-10 [S] DAT 72 Data Cartridges, 10 pack
370-6908 [S] DAT 72 Data Cartridge n/a
SG-XTAPDAT72-5F-2 [S] 380-1324 [F] DAT 72 Internal Tape Drive, 5.25 inch/68 pin SCSI, n/a
SG-XTAPDAT72-5F68 [S] 380-1004 [F] 36-72GB 4 mm DAT 72 Tape Drive n/a
X6168A [S] 390-0025 [F] 10X DVD-ROM Drive n/a
X6283A [S] 370-2376 [F] 12-24GB 4 mm DDS-3 Tape Drive (Medium Grey Bezel) n/a
X6295A [S] 390-0028 [F] 20-40GB 4 mm DDS-4 Tape Drive (Medium Grey Bezel) n/a
NOTE: Any 50-pin device being added to the second and/or third media slots require the X913A adapter.
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
SGXPCI2SCSILM320-Z Price 375-3365 31 [F] PCI Dual Ultra320 SCSI Adapter, L n/a
SG-XPCI2SCSI-LM320 [S] 375-3191 [F] PCI/PCI-X Dual Ultra320 SCSI Adapter n/a
X1032A [S] 501-5656 [F] Single-Ended Ultra/Wide SCSI/FastEthernet (SunSwift PCI) n/a
X2222A [S] 501-5727 [F] Dual FastEthernet / Dual SCSI PCI Adapter n/a
X4422A [S] 501-6635 [F] Dual GigabitEthernet / Dual SCSI PCI Adapter n/a
X6540A [S] 375-0005 [F] Dual Single-Ended Ultra/Wide SCSI (PCI) n/a
X6541A [S] 375-0006 [F] Dual Differential Ultra/Wide SCSI (UDWIS/P)(HVD) n/a
X6758A [S] 375-3057 32 [F] PCI Dual Ultra3 SCSI Host Adapter (LVD) n/a
31 Ultra320 SCSI HBA (375-3365-01 REV 52) FCode 1.13 fails to work on all Sun Platforms, replace it with 375-3365-02 REV 50. See Problem article 1013105.1.
32 The necessary drivers (SUNWqus, SUNWqusu, SUNWqusx, & SUNWqusux) and patches for this product are not included in Solaris 8 or 9, but must be downloaded. Please see How To article 1018123.1 for details.
System Board
Option # Manufacturing
Part #
Description Previous
Part #
X6894A [S] CPU/Memory Board w/ 2× US III Cu 1050MHz, 4GB Memory
501-6163 [F] CPU/Memory Board w/ 2× US III Cu 1050MHz, 0MB
(Cheetah++ 527-1033)
501-6534
X6895A [S] CPU/Memory Board w/ 2× US III CU 1200MHz, 4GB Memory
501-6164 [F] CPU/Memory Board w/ 2× US III Cu 1200MHz, 0MB
(Cheetah+)
n/a
X7028A [S] CPU/Memory Board w/ 2× US III Cu 900MHz, 4GB Memory
501-6676 [F] CPU/Memory Board w/ 2× US III Cu 900MHz, 0MB
(Cheetah+ 2.2/2.3) FAB 270-6164
501-6334 [F] 
X7046A [S] 501-6360 [F] CPU/Memory Board w/ 2× US III 750MHz, 0MB
(Cheetah), 2× 3.3V DC-DC Converter
n/a
X7047A [S] CPU/Memory Board w/ 2× US III 750MHz, 4GB Memory
501-6360 [F] CPU/Memory Board w/ 2× US III 750MHz, 0MB
(Cheetah), 2× 3.3V DC-DC Converter
n/a
X7272A [S] CPU/Memory Board w/ 2× US III CU 1200MHz, 8GB Memory
501-6164 [F] CPU/Memory Board w/ 2× US III Cu 1200MHz, 0MB
(Cheetah+)
n/a
n/a 501-4300 [F] Motherboard n/a
n/a 501-5818 [F] CPU/Memory Board w/ 2× USP III 750MHz, 0MB
(Cheetah), 1× 3.3V DC-DC Converter
n/a
n/a 501-6323 [F] Motherboard n/a
n/a 501-6334 [F] CPU/Memory Board w/ 2× US III Cu 900MHz, 0MB
(Cheetah+ 2.2/2.3) FAB 270-4150
n/a
n/a 501-6677 [F] CPU/Memory Board w/ 2× US III Cu 1050MHz, 0MB
(Cheetah+) FAB 270-6164-01
n/a
n/a 501-6706 [F] CPU/Memory Board w/ 2× US III Cu 1050MHz, 0MB
(Cheetah+) FAB 270-6164-02
n/a
n/a 501-6707 [F] CPU/Memory Board w/ 2× US III 1050MHz, 0MB
(Cheetah++ 527-1116)
n/a
n/a 501-6731 [F] CPU/Memory Board w/ 2× US III Cu 900MHz, 0MB
(Cheetah+ 2.2) Reworked 501-6334-02
n/a
n/a 501-6752 [F] Motherboard n/a
n/a 501-6753 [F] Motherboard n/a
n/a 501-6771 [F] Motherboard n/a
n/a 501-7199 38 [F] Motherboard n/a
n/a 595-5531 Sun Fire CPU/Memory Board w/ 2 UltraSPARC III 750MHz w/ 0GB 1x 3.3V DC-DC Converter n/a
n/a 595-6211 Sun Fire CPU/Memory Board w/ 2 UltraSPARC III 750MHz w/ 4GB RAM (16 × 256MB DIMMs) n/a
33 501-7199 requires >=OBP 4.18.1
34 501-7199 requires >=OBP 4.18.1
35 501-7199 requires >=OBP 4.18.1
36 501-7199 requires >=OBP 4.18.1
37 501-7199 requires >=OBP 4.18.1
38 501-7199 requires >=OBP 4.18.1
NOTE: >= 1050MHz System Boards require that all memory DIMM slots be fully populated. Minimum OBP is 4.7.5. Although the above information states the minimum OBP levels, OBP 4.10.8 or higher is highly recommended for 900MHz and faster CPUs. Mixing CPU speeds within a V880 is not supported.

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

Sun Fire V880 Exploded View
Sun Fire V880 Exploded View
Sun Fire V880 Exploded View
Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
1 370-3957 Lower Disk LED Flex Circuit, L
2 370-3958 Upper Disk LED Flex Circuit, L
3 540-3694 [F] System Status Assembly
4 330-2399 [F] 5 1/4" Device External Filler Panel,
5 330-2400 [F] 3 1/2" Device External Filler Panel,
6 340-5934 3 1/2" Device Internal Filler Panel
7 340-5933 5 1/4" Device Internal Filler Panel
8 340-4895 FC-AL Backplane Filler Panel
9 370-3962 [F] I/O Fan LED Flex Circuit, L
10 370-3964 [F] PCI Internal LED Flex Circuit, L
11 540-4454 [F] CPU/Memory Board Status Assembly
12 540-4453 [F] CPU Fan Status Assembly
NS
  • 541-1092 [F]
  • CPU Fan Status Panel, L
13 340-6030 CPU Fan Tray Filler Panel
14 370-3960 [F] Motherboard Fan Status Flex Circuit, L
15 370-3963 [F] PCI External LED Flex Circuit, L
16 340-5519 Power Supply Filler Panel
17 540-4507 Disk Drive Enclosure w/o Status Panels
NS 330-2014 [F] AC Power Key / Door Key,
NS 330-3284 CPU/Memory Board Connection Cover
NS 340-6627 PCI Filler Panel,
NS 530-2548 [F] RME Power Cable,
NS 530-2569 [F] RME Wide SCSI Cable
NS 530-2621 [F] FC-AL Data Cable (short, 23cm)
NS 530-2622 [F] FC-AL Data Cable (medium, 44cm)
NS 530-2623 [F] FC-AL Data Cable (long, 95cm)
NS 530-2745 [F] I/O Board Remote Sense Cable
NS 530-2746 [F] I/O Signal Cable,
NS 530-2747 [F] Fan Power Cable
NS 530-2748 [F] RME Narrow SCSI Cable
NS 530-2816 [F] Motherboard Power Cable
NS 530-2818 [F] I/O Board Cable
NS 530-2835 [F] PCI Internal Status Cable,
NS 530-2836 [F] PCI External Status Cable,
NS 530-2837 [F] CPU/Memory Board Status Assembly Cable,
NS 530-2838 [F] PCI/CPU/SCHIZO Fan Status Cable,
NS 530-2839 [F] I/O Board to Keyswitch/Status Panel Cable,
NS 530-2840 [F] I2C Cable
NS 530-2841 [F] Base Backplane Power Cable
NS 530-2863 [F] Base / Expansion Power and ID Cable
NS 530-3096 Power Cord IEC 320-C13 to IEC 320 Sheet E 2.5M,
NS 540-3606 Right Side Panel/Door
NS 540-3607 Left Side Panel/Door
NS 540-3608 Front Door with lock assembly
NS 540-4431 39 CPU/Memory Board Air Baffle Assembly
NS
  • 230-1763
  • Plunger/Fastner
NS
  • 230-1769
  • Grommet
NS
  • 330-2580
  • CPU/Memory Board Filler Panel / Air Baffle
NS 560-2629 RME Device Rail Kit, A30
39 These yellow air baffles are shipped inside of every Sun Fire V880 and Sun Fire V890. See the Right Open View for installation and storage locations.
  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback