High Speed Serial Interface (HSI/P)
Workstations: |
Ultra 5, 10, 30, 60, 80, 450, 25, 45
Sun Blade 100, 150, 1000, 1500, 2000, 2500 |
Servers: |
Enterprise 250, 450, 220R, 420R
Enterprise 3x00, 4x00, 5x00, 6x00
Sun Fire 280R, V480, V490, V880, V890
Sun Fire V120, V1280, V240, V250, V440
Sun Fire 4800, 4810, 6800, 12K, 15K, E2900, E4900, E6900 |
Telco: |
Netra T1, 20, 120, 240, 440, 1280
Netra t1120/1125, t1400/1405, ft 1800 |
Options 1040 / 1155 / 6931
370-2728 |
540-3982 |
Performance Technologies PT-PCI334-10592
5V 32Bit 33MHz |
Netra ft 1800 FRU
with 370-2728 |
Jumper Settings
JUMPERS |
PINS |
SETTING |
DESCRIPTION |
K1 |
1-2 |
Out |
Burn-In disabled |
K2 K3 |
1-2 1-2 |
In Out |
Max Power = 25W
Max DRAM 32MB |
K2 K3 |
1-2 1-2 |
Out In |
Max Power = 15W (default)
Max DRAM 8MB (default) |
K2 K3 |
1-2 1-2 |
In In |
Max Power = 7.5W
Max DRAM 2MB |
K2 K3 |
1-2 1-2 |
Out Out |
Max Power = 0W
Max DRAM 0MB |
Connectors
LOCATION |
PINS |
DESCRIPTION |
J1 |
72 |
SIMM socket |
J2 |
80 |
RS-449 (422) port |
P1 |
3 |
Debug port |
P2 |
10 |
Background Debug Mode (BDM) port |
P3 |
1 |
Clock test |
P4 |
34 |
Data bus test (not stuffed) |
P5 |
18 |
Control test (not stuffed) |
P6 |
34 |
Address bus test (not stuffed) |
Notes
- The HSI/P supports 1MB through 32MB, 72-Pin, 5 Volt SIMMs.
- A 4MB SIMM is installed as a standard configuration.
- The 4MB SIMM does not have a Sun part number.
- The BDM port is defined in the QUICC Users Manual, Section 9.9.
- The HSI/P Cable provides four DB37 connectors.
- The HSI/P is not supported on the PCI+ I/O assembly (540-6247)
Operating System Notes
- The minimum operating system is Solaris 2.5.1 Hardware: 4/97.
- The HSI/P 1.0 software is on CD-ROM 704-5748-10.
- The HSI/P 2.0 software is on CD-ROM 704-6439-10.
- Option 1155 includes HSI/P 2.0 for Solaris 7.
- The Solaris 8 Supplement includes HSI 3.0 software.
- Solaris messaging identifies the card as "pci1214,334".
Reference
-
HSI/P Users Guide, 805-1075.
|