 Quad GigaSwift Ethernet UTP
 
| Workstations: | Sun Blade 100, 150, 1000, 1500, 2000, 2500 |  
| Servers: | Enterprise 220R, 250, 420R, 450 Sun Fire V120, V210, V240, V250, V440, V490, V890
 Sun Fire 280R, V480, V880, 12K, 15K, E20K, E25K
 Sun Fire V20z, V40z, 4800, 6800, E4900, E6900
 |  
| Telco: | Netra 20, 120, 240, 440 Netra T1 AC200/DC200, t1120/1125, t1400/1405
 |  Option 4444
| 501-6522 |  
| Unshielded Twisted Pair 3.3/5V   32/64Bit   33/66MHz
 |   
 Notes
The minimum operating system is Solaris 7.
The Quad GigaSwift Ethernet ce device driver requires Solaris 7 Patch
     112327-17,
    Solaris 8 Patch  111883-23,
    or Solaris 9 Patch  112817-16.To configure 501-6522 into an hsPCI I/O assembly (option X4575A) on
    Sun Fire 12K or 15K, the following patches are required:On Solaris 8: >=
  116962-01 On Solaris 9: >=
  117171-07The minimum operating system for the VLAN Utility is Solaris 8.
The VLAN Utility requires Solaris 8 Patch
     112119-04
    or Solaris 9 Patch  114600-02.Use 1.5' Ethernet Cable 530-3335 without locking tab and
    RJ45 Female to Female Adapter 130-5586 to workaround BugID 5011918
    against 501-6522-06.(Cable Kit 530-3336 includes 530-3335 and 130-5586.)
 530-3335 and 130-5586 briefly shipped with X4444A until 501-6522-07 was
    released.
501-6522-07 fixes BugID 5011918
    (WO_29531, July 2004)
    by positioning connector orientation tab down:
  Refer to Sun Alert article
  1000479.1
  for information about forced mode with the CE driver.
 References
 Quad GigaSwift Ethernet UTP Adapter Installation and User's Guide, 817-2974. 
 |