How Tos
|
Former IBIS ID
|
Synopsis
|
Last Modified Date
|
1325039.1 |
|
DIMM Size Reference Sheet for Sun Fire Midrange and Highend Servers |
2011-05-25
|
1019337.1 |
238627 |
Introduction to cache-line retirement feature for Ultrasparc-IV+ (USIV+) processors |
2010-07-06
|
1018896.1 |
230737 |
Sun Fire[TM] 12K/15K/E20K/E25K: Management Networks (MAN) |
2010-09-16
|
1018796.1 |
230578 |
Sun Fire[TM] 12K/15K/E20K/E25K Platform: Complete procedure for creating and OS loading a new Starcat domain. |
2011-05-25
|
1018764.1 |
230492 |
Sun Fire[TM] Servers: 12K/15K/E25K/E20K: Cheat Sheet: SMS Command Privileges |
2010-06-21
|
1018758.1 |
230485 |
Sun Fire[TM] 12K/15K/E20K/E25K: Split Expander Considerations |
2010-08-06
|
1018757.1 |
230484 |
Sun Fire[TM] 12K/15K/E20K/E25K: Cheat Sheet: I2C Buses/Addresses |
2011-02-02
|
1018756.1 |
230483 |
Sun Enterprise[TM]10000 / Sun Fire[TM] 12K/15K/E20K/E25K servers: Dynamic Reconfiguration (DR) Cheat Sheets |
2011-05-11
|
1018123.1 |
229447 |
StorEdge[TM] PCI Dual Ultra3 SCSI Host Adapter Requirements |
2011-03-08
|
1018053.1 |
229360 |
Sun Fire[TM] Servers (12K/15K/E20K/E25K): POST Level |
2011-01-25
|
1017931.1 |
229192 |
Sun Fire[TM] 15K: Setting up SMS 1.2 "mld" service to receive domains syslog messages |
2009-02-26
|
1017736.1 |
228947 |
using psrset to bind oracle db server to set of CPU's during startup |
2009-11-19
|
1017647.1 |
228831 |
Sun Fire[TM] 12K/15K/E20K/E25K: incorrect character shown on SC's LED display |
2010-06-21
|
1017551.1 |
228696 |
Sun Fire[TM] Servers: 12K/15K/E25K/E20K: SMS System Controller Communication; zoed |
2010-06-21
|
1013021.1 |
217823 |
Upgrading System Disk Firmware without Downtime |
2011-05-11
|
1012638.1 |
217387 |
Sun Fire[TM] 12K/15K/E20K/E25K, Sun Fire V1280/4800/6800/E2900/E4900/E6900, Netra 1280/1290 servers: UltraSPARC IV+ DR restrictions on Solaris9 Update8 |
2009-11-30
|
1012349.1 |
217037 |
Kernel Cage Splitting Overview |
2010-01-06
|
1012305.1 |
216980 |
Sun Fire[TM] 15K/12K Servers: DR attach/detach operations failing due to portid conflicts arising from third party device drivers |
2010-08-11
|
1012287.1 |
216961 |
Sun Fire[TM] Servers: 12K/15K/E25K/E20K: Platform Identification on Highend Systems |
2011-05-23
|
1012284.1 |
216949 |
Sun Fire[TM] 12K/15K/E20K/E25K: Fastest Way to Move System Boards(SB) Between Domains. |
2011-04-26
|
1012194.1 |
216813 |
Sun Fire[TM] Servers: Memory Placement Optimization (MPO) Frequently Asked Questions (FAQ) |
2011-01-12
|
1012186.1 |
216797 |
Sun Fire[TM] Server: How to Use Dynamic Reconfiguration (DR) in a Sun Cluster[TM] 3.x Environment |
2011-02-22
|
1012140.1 |
216722 |
Sun Fire[TM] 12K/15K/E20K/E25K: MAN Interface Mapping |
2010-06-15
|
1012092.1 |
216624 |
Sun Fire[TM] 12K/15K/E20K/E25K: Decoding Safari bus error CSR to a hardware device |
2011-04-20
|
1012043.1 |
216501 |
Processor may be Incorrectly Offlined When it Encounters a UCC + ME bit set in AFSR |
2010-07-06
|
1011988.1 |
216430 |
Sun Fire[TM] 12K/15K/E20K/E25K: How to translate a DIMM Slot SubSlot message from the System Controller platform messages file into a physical location. |
2011-06-03
|
1011252.1 |
215454 |
Sun Fire[TM] 12K/15K/E20K/E25K Servers: POST settings for Memory Page Retirement support |
2009-11-30
|
1010919.1 |
215064 |
Understanding and Troubleshooting VCMON & CSTH-LITE errors |
2011-04-28
|
1010905.1 |
215045 |
Sun Enhanced Memory DIMM Replacement Policy for SPARC |
2011-04-13
|
1010903.1 |
215043 |
Sun Fire[TM] Servers: 12K/15K/E20K/E25K: How to Flash Update a System Board in conjunction with Dynamic Reconfiguration. |
2011-05-19
|
1010837.1 |
214967 |
Sun Fire[TM] 12K/15K/E20K/E25K, Sun Enterprise[TM] 10000 servers : Site Planning Considerations Using Redundant AC Power Sources |
2010-06-21
|
1010760.1 |
214863 |
Sun Fire[TM] 15K/12K/E20K/E25K Servers: What Happens in a DR Slot0 Attach Operation |
2010-06-16
|
1010757.1 |
214857 |
Sun Fire[TM] 12K/15K Servers: Voltage Error on CPU Leads to Blacklisting the PROCPAIR |
2009-09-24
|
1010723.1 |
214798 |
Procedure for Startup and Shutdown of Sun Fire[TM]12K/15K domains and frame |
2011-05-03
|
1010485.1 |
214399 |
Sun Fire[TM] 12K/15K/E20K/E25K: Summary of System Controller (SC) Commands |
2011-05-31
|
1010444.1 |
214352 |
Sun Fire 12K/15K/E20K/E25K Server: ACL usage and common error messages |
2011-02-04
|
1010412.1 |
214301 |
Sun Fire[TM] 12K/15K/E20K/E25K: Procedure to change the public hostname of a domain |
2009-12-03
|
1010363.1 |
214215 |
Sun Fire[TM] 12K/15K/E20K/E25K Servers: Dynamic Reconfiguration Considerations |
2011-02-17
|
1009465.1 |
213076 |
Sun Fire[TM] 12K/15K/E20K/E25K, Sun Fire V1280/4800/6800/E2900/E4900/E6900, Netra 1280/1290 servers: UltraSPARC IV+ DR restrictions on Solaris10 HW1 |
2010-07-06
|
1009357.1 |
212943 |
Sun Fire[TM] 12K/15K/E20K/E25K servers: System Controller serial port configuration |
2011-01-04
|
1009338.1 |
212920 |
CP2140 in Sun Fire[TM] F12K, F15K, E20K and E25K: What does "Loading PCI debug and information words:" mean? |
2010-05-18
|
1009222.1 |
212762 |
Sun Fire[TM] 15K/12K Servers: setkeyswitch ops report "[5358] Transmission or pcd(1M) handling of domain-down event failed: ecode=1711" |
2011-05-30
|
1009212.1 |
212749 |
Sun Fire[TM] 12K/15K/E20K/E25K: Solaris[TM] and SMS requirements and recommendations |
2011-02-08
|
1009201.1 |
212736 |
SunVTS[TM] command line syntax for SunVTS[TM] 5.1 |
2010-12-30
|
1009147.1 |
212657 |
Sun Fire[TM] 12K/15K/E20K/E25K: Procedure for applying Solaris[TM] and SMS patches to System Controllers |
2011-05-31
|
1009071.1 |
212508 |
SunFire[TM] 12K/15K/20K/25K: During POST Cycle, "lock_retries" Messages Appear |
2011-05-26
|
1009048.1 |
212474 |
Sun Fire[TM] 12K/15K/E20K/E25K: Changing the IP address for the C (Community) Network |
2011-05-02
|
1008920.1 |
212274 |
Sun Fire[TM] 12K/15K/E20K/E25K: Changing Host Names on the System Controllers |
2010-05-27
|
1008075.1 |
211118 |
Sun Fire[TM] E25K, E20K, E15K, E12K : BERR panic events off PCI-X/PCI Quad Gigaswift ethernet card installed on schizo based hsPCI slot |
2010-06-16
|
1008055.1 |
211094 |
Sun Fire[TM] 12K/15K/E20K/E25K: SMS 1.6 + Solaris[TM] 10 deployed CP1500 based SC's C1 network interfaces reported with non-unique MAC address |
2011-05-18
|
1007746.1 |
210728 |
SunFire[TM] 12K/15K/E20K/E25K: Expected behavior of domains in different scenarios when the SCs are powered down or rebooted |
2011-05-10
|
1007669.1 |
210624 |
Torque driver settings in SI units. |
2009-10-30
|
1007600.1 |
210515 |
Sun Fire[TM] Servers: Dynamic Reconfiguration (DR) Module Not Installed During Agent Installation of Sun[TM] Management Center 3.5 V4 on High-End Servers |
2009-09-13
|
1007586.1 |
210494 |
smsconfig -s ssh can fail with "Permission denied" when sshd_config includes 'Banner' directive |
2010-08-27
|
1007568.1 |
210473 |
Sun Fire[TM] 12K/15K/E20K/E25K: Testing a single slot 0 board with no slot 1 board in a domain |
2011-05-23
|
1006927.1 |
209596 |
Sun Fire[TM] 12K/15K/20K/25K : "EpiSchizoEccR1_sc_tfunc(): ALERT: DXs do not report seeing forced ECC" from SMS1.6 POST run |
2009-12-03
|
1006645.1 |
209268 |
What is a Solaris[TM] PCI IOMMU error telling me? |
2010-05-19
|
1006623.1 |
209238 |
Domains on Sun Fire [TM] 12k/15k/E20k/E25k may dstop when SMS is simultaneously started on both SCs |
2010-07-20
|
1006613.1 |
209226 |
Sun Fire[TM] 12K/15K/E20K/E25K: Incorrect permission(s) on SMS Directories |
2011-06-06
|
1006509.1 |
209107 |
Sun Fire[TM] 12K/15K/E20K/E25K servers: System Controller, Solaris[TM] OS installation, and Solaris[TM] Volume Manager (SVM) Configuration |
2011-05-10
|
1006489.1 |
209085 |
Sun Fire[TM] 12K/15K/E20K/E25K: Main System Controller's Community Network (C1) interface failure causes a failover onto the Spare SC. |
2010-06-07
|
1006441.1 |
209030 |
FRUID capture and collection through Sun Explorer |
2010-05-18
|
1006214.1 |
208696 |
Sun Fire[TM] 12K/15K/E20K/E25K Servers: How to Replace a System Board Using Dynamic Reconfiguration |
2011-05-23
|
1006140.1 |
208600 |
Sun Fire[TM] 12K/15K/E20K/E25K: How to translate an E$ Slot SubSlot messages from the System Controller platform messages file into a physical location. |
2010-09-13
|
1006092.1 |
208497 |
Sun Fire[TM] 12K/15K/E20K/E25K: Enterprise Installation Standards(EIS) EEPROM settings |
2011-05-10
|
1006073.1 |
208469 |
Sun Fire[TM] Servers: 12K/15K/E25K/E20K: Sun[TM] Management Center and SMS |
2009-11-29
|
1005605.1 |
207781 |
Understanding which network interface will be used for a network boot on Sun SPARC(R) systems |
2011-05-18
|
1005403.1 |
207524 |
Sun Fire[TM] 3800-6800/12K-E25K servers: Capacity on Demand (COD) How to activate CPU's into a domain? |
2010-05-21
|
1005287.1 |
207393 |
Sun Fire[TM] Servers: 12K/15K/E20K/E25K: A196 Power Supply Upgrade Rules |
2011-05-23
|
1005025.1 |
207052 |
IPMP with Dynamic Reconfiguration (DR) |
2011-03-02
|
1004870.1 |
206832 |
Sun Fire[TM] V1280-E15000:Tech Tip:An offlined processor can be involved in a panic in rare cases |
2010-07-06
|
1004845.1 |
206790 |
Sun Fire[TM] Midrange and HighEnd Servers: Discussion of Component Health Status (CHS) |
2010-06-18
|
1004838.1 |
206774 |
Solaris[TM] and Minimum O.S. distribution requirements for Sun[TM] Cluster 3.x |
2009-02-17
|
1004773.1 |
206625 |
Sun Fire[TM] 12K/15K/E20K/E25K: Solaris[TM] Operating System I/O Device Probing and Configuration |
2011-05-18
|
1004222.1 |
205841 |
How to setup console logging and obtain diagnostic data from different types of SPARC servers |
2011-03-10
|
1003922.1 |
205498 |
Machine won't boot off network, CDROM, or DVD |
2011-05-24
|
1003867.1 |
205430 |
Memory DIMM Replacement Management Tool - cediag FAQ |
2011-03-14
|
1003582.1 |
205053 |
Sun Fire[TM] 12K/15K/E20K/E25K: What Happens in a DR Slot0 Detach Operation |
2010-06-10
|
1003575.1 |
205032 |
Sun Fire[TM] F12K/F15K/E20K/E25K: Component Health Status (CHS) - Q and A |
2010-08-18
|
1003507.1 |
204930 |
Sun Fire[TM] Servers: Differences Between PCI-X and PCI Express I/O Technologies |
2009-12-04
|
1003494.1 |
204913 |
Sun Fire[TM] 12K/15K/E20K/E25K: "Minimum proc_dump_delay has not been met." message during POST. |
2010-01-01
|
1003456.1 |
204843 |
STMS (MPxIO) degraded path messages seen at Solaris[TM] 8, 9 or 10 boot time. |
2010-07-22
|
1003415.1 |
204790 |
Sun Fire[TM] 12K / 15K / E20K / E25K: Platform Configuration Database (PCD) Daemon Data Description |
2009-11-30
|
1003403.1 |
204776 |
Sun Fire[TM] 15K/12K: CP1500 Nordica board LCD display characters and their meanings |
2009-09-22
|
1003372.1 |
204694 |
Sun Fire[TM] 12K/15K/E20K/E25K servers: Firmware Revisions |
2011-06-07
|
1003344.1 |
204643 |
Sun Fire[TM] 12K/15K/20K/25K: Clock Management |
2010-05-26
|
1003335.1 |
204631 |
Sun Fire[TM] 12K/15K: Cheat Sheet: CPU and Domain Signatures |
2010-05-26
|
1003319.1 |
204606 |
Sun Fire[TM] 12K/15K/E20K/E25K: POST level increments with repeated error |
2011-06-03
|
1003299.1 |
204578 |
Sun Fire[TM] 12K/15K/E20K/E25K server: SMS File System Layout |
2009-12-03
|
1002408.1 |
203371 |
Sun Fire[TM] 12K/15K: showdevices fails with "dcs: <11989> resource info init error (1)" |
2009-09-28
|
1002268.1 |
203193 |
Sun Fire[TM] 12K/15K/E25K/E20K Servers: nfs.server and tftpboot services may be open on a System Controller that has Solaris[TM] Security Toolkit software installed or System Management Services 1.5 with Secure by Default. |
2009-09-24
|
1002109.1 |
203006 |
Sun Fire[TM] 12K/15K/E20K/E25K: POST Overview |
2011-05-27
|
1002075.1 |
202916 |
System Management Services(SMS) software: Upgrade Requirements |
2011-06-09
|
1001900.1 |
202634 |
Sun Fire[TM] 12K/15K: Checking and Updating SC Firmware(FW) Guidelines |
2011-01-21
|
1001879.1 |
202571 |
Sun Fire[TM] 12K, 15K, E20K, and E25K: Determining slot numbers from I/O device paths |
2011-04-19
|
1001867.1 |
202557 |
Sun Fire[TM] 3800-6800/12K-E25K servers: What is Capacity on Demand (COD) and what are its commands? |
2010-07-20
|
1001683.1 |
202288 |
Sun Fire[TM] 12K/15K/E20K/E25K: Location and Relocation of Kernel for DR Operations |
2011-05-19
|
1001653.1 |
202249 |
Understanding Oracle Solaris Time Sharing(TS) Dispatch Tables for Low- and High-end Servers |
2010-08-26
|