Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1003403.1 : Sun Fire[TM] 15K/12K: CP1500 Nordica board LCD display characters and their meanings
PreviouslyPublishedAs 204776 Description The CP1500 board in a 12K/15K system controller has an LCD screen, labeled the Display screen in the Sun[TM] System Handbook. This display screen shows a letter or number, or cycle of letters depending on the current status of the system controller. The table below describes what each of these characters represent. Steps to Follow Character Representation ---------------------------------------------------------- d POST invoked. 1 Init System BSS 2 Ecache tests 3 all CPU basic tests 3 all basic MMU tests 3 all basic cache tests 4 memory Probe and Init 4 all FPU basic tests 4 memory tests 5 all basic CPU IO tests 6 all advanced CPU tests 6 all CPU error reporting tests 7 all advanced CPU IO tests 8 all basic PCIO tests 9 all basic I2C tests 9 all basic PCI-to-PCI Bridge tests 9 all basic Symbios 875 SCSI controller tests P POST exits with status = PASS. F POST exited with status = FAIL. O (The letter O ) OBP is currently executing. E RED state exception encountered in OBP. A Detection of a BREAK combination. b Solaris boot has taken place. H, E, L, P This sequence (with each letter flashed at a 4-second interval) is initiated if the system is at the ok prompt for more than two minutes after power-on, without booting. It does not appear after Solaris[TM] has booted. Product Sun Fire 15K Server Sun Fire 12K Server Internal Comments References: SPARCengine CP1500 360MHz/440MHz Technical Reference and Installation Manual http://www.sun.com/products-n-solutions/nep/hardware/boards/cp1500/docs/techman.pdf SPARCengine CP1500 http://sunsolve.central.sun.com/handbook_internal/Devices/System_Board/SYSBD_SPARCengine_CP1500.html#5473 Nordica, CP1500, SC, LCD, LED, Display, post, obp Previously Published As 71040 Change History Date: 2004-02-17 User Name: 36260 Action: Approved Comment: Added missing trademark and corrected some grammar. Version: 0 Date: 2004-02-17 User Name: 72607 Action: Approved Comment: I agree with Josh to open this doc for free audience. I just fixed one of the internal references, because the FEHandbook URL has been moved. No more comments, please publish. Version: 0 Date: 2004-02-13 User Name: 103287 Action: Approved Comment: Made the doc Free so that a customer can tell what the status LCD represents without having to log a call. Depending on the status, they will be able to decide if a call is needed to support. Version: 0 Date: 2004-02-13 User Name: 103287 Action: Updated Comment: Changing audience Version: 0 Date: 2003-07-31 User Name: 43660 Action: Approved Comment: Useful article. Added trademarks. Version: 0 Date: 2003-07-31 User Name: 101037 Action: Approved Comment: Looks good Version: 0 Date: 2003-07-30 User Name: 103287 Action: Approved Comment: Ran across this info on the alias and haven't seen it on sunsolve, so thought it useful. Prompted by questions from HAS team ont he subject... Version: 0 Date: 2003-07-30 User Name: 103287 Action: Created Comment: Version: 0 Product_uuid 29e4659c-0a18-11d6-9fa1-e67bbc033df8|Sun Fire 15K Server 077fd4c5-df8f-4320-ad69-7d01603a674d|Sun Fire 12K Server Attachments This solution has no attachment |
||||||||||||
|