Solution Type  Technical Instruction Sure

Solution  1006092.1 :   Sun Fire[TM] 12K/15K/E20K/E25K: Enterprise Installation Standards(EIS) EEPROM settings  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
208497


Applies to:

Sun Fire 12K Server
Sun Fire 15K Server
Sun Fire E20K Server
Sun Fire E25K Server
All Platforms

Goal

The pre-Installed EEPROM settings on the SC's are as follows:
setenv auto-boot          false
setenv diag-level         pmax-epvmax
setenv input-device       ttya
setenv output-device      ttya
setenv local-mac-address  true
setenv diag-switch        true
setenv post-on-sir        true
setenv diag-device        
Some of these settings are changed during a normal Enterprise Installation Standards(EIS) installation. By following the EIS standards, the result is a consistent, high quality, and cost-effective installation that speeds up the time to deployment, and provides the foundation for enhanced stability and performance. This document is intended to provide the EIS standard EEPROM settings for those who do not have access to the EIS CD.

Solution

These setting are critical to the System Controller (SC) operation. The settings on SC0 and SC1 should be as follows:

Post-Installation EIS applied EEPROM changes:
On both SC's:
auto-boot     true
diag-switch   true
On SC0:
diag-level pmax-epmax
On SC1:
diag-level pmax-epvmax
The value for  auto-boot will insure that the SC will reboot if it should crash, and diag-switch is set to true, so that the SC will run in diagnostic mode.
The more verbose diag-level on SC1 will delay the POST completion and thus will ensure that there is no race condition for the MAIN role if both SCs are started at the same time, and that SC0 will come up as MAIN.

If  SC0 is not the MAIN, or if an SC failover occurs, the values for diag-level do not need to be changed.


Questions comments: [email protected]

Also see: HAS Team Web page which is currently located at http://has.us.oracle.com/ or http://mcst.us.oracle.com/

The complete EIS SF 12K/15K/E20K/E25K checklist is currently located at http://eis.central/checklists/pdf/SF15K-e.pdf

Eprom, EEPROM, terminal, settings, tty, pmax-epmax
Previously Published As
53501

Change History
Date: 2009-11-18
User Name: Volkmar Grote 117021
Action: Reviewed for Content Team
Comment: only changed the EIS URL
Date: 2004-12-07
User Name: 36642
Action: Approved
Comment: I updated the title and some sentences. It was already trademarked, so it is ready for SunSolve.

Version: 9
Date: 2004-12-06
User Name: 36642
Action: Accept
Comment:
Version: 0
Date: 2004-12-06
User Name: 103287
Action: Approved
Comment: Looks good.
Version: 0


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback