Where are SMS files located within the System Controller file system?
For example, where is the asr blacklist file?

Notes:
  • asr = Automatic System Recovery
  • sms = System Management Services


Steps to Follow
The SMS File System Layout is as follows:
-/opt/SUNWSMS/SMS1.x
|--/man
|
|--/lib
|
|--/bin
|
|--/firmware (sc firmware binaries)
|
|--/hostobjs (system board firmware binaries)

-/var/opt/SUNWSMS/SMS1.x
|
|--/.lock
|
|--/.pcd
|
| domain_info
| platform_info
| sysboard_info
|
|--/adm
| |
| |--
| | |
| | | console
| | | messages
| | | syslog
| | |
| | |--/dump
| | |
| | |--/post
| |
| |
| |--/platform
| |
| | messages
| |
| |--/dump
| |
| |--/events
| |
| | |--eventlog (SMS 1.4.1)
| |
| |--/trace
| |
| |--tracejournal (SMS 1.4.1)
|
|--/data
| |
| |--/
|
| idprom.image
| nvramdata
|
|--/doors
|
|--/pipes

-/etc/opt/SUNWSMS
|
|--/startup
|
| sms
| sms_env
| smsstartup
|
|--/config
| |
| | MAN.cf (network config file)
| | cod.cf
| | dsmd_tuning.txt
| | esmd_tuning.txt
| | fomd.cf
| | fomd_sys_datasync.cf
| | kmd_policy.cf
| | mld.cf
| | mld_tuning
| | event_email.cf
| | elad_tuning.txt
| |
| |--/
| |
| | blacklist (domain blacklist file)
| | .postrc (domain post config file)
| |
| |--/asr
| |
| | blacklist (asr blacklist file)
| |
| |--/platform
|
| blacklist (platform blacklist file)
| .postrc (platform post config file)

/export/home/sms-svc


Product
Sun Fire 15K Server
Sun Fire E25K Server
Sun Fire E20K Server
Sun Fire 12K Server

SMS, starcat, asr, file system, file location, blacklist, SUNWSMS, configuration, file
Previously Published As
48135

Change History
Date: 2009-11-23
User Name: Josh Freeman
Action: Updated
Comment: Made this a Technical Instruction article because that is what it is.
Date: 2005-11-10
User Name: 18392
Action: Approved
Comment: Expanded abbreviations.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback