Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1005403.1
Update Date:2010-05-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  1005403.1 :   Sun Fire[TM] 3800-6800/12K-E25K servers: Capacity on Demand (COD) How to activate CPU's into a domain?  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire 15K Server
  •  
  • Sun Fire 4810 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
207524


Description
After the licenses are ordered, delivered and entered into the Systems Controller configuration how do I bring the newly licensed CPU's into the domain configuration?


Steps to Follow
POST or HPOST evaluates the state of the licenses on the particular platform when it runs.
stage_cpu_lpost(): No NMB Boards in config. Skipping Stage nmb_cpu_lpost.

Acquiring licenses for all good processors...
Proc SB17/P3 deconfigured: no license available.
Proc SB17/P1 deconfigured: no license available.
......

Therefore in order to activate COD licenses into a domain POST needs to run. So we have the following options:

  1. Option 1; Keyswitch the domain domain off (or standby) and on to make post evaluate the license situation again.
  1. Option 2: DR a Uniboard (SB) out the domain and back in:

From the Systems controller:

SC> addcodlicense verylonglicensestringhere
SC> deleteboard SB1
SC> addboard SB1

From the domain:

SC> addcodlicense verylonglicensestringhere
DOMAIN> cfgadm -c disconnect SB1
DOAMIN> cfgadm -c configure SB1

On single board domains only option 1 can be used.



Product
Sun Fire V1280 Server
Sun Fire E6900 Server
Sun Fire E4900 Server
Sun Fire E2900 Server
Sun Fire 6800 Server
Sun Fire 4810 Server
Sun Fire 4800 Server
Sun Fire 3800 Server
Sun Fire E25K Server
Sun Fire E20K Server
Sun Fire 15K Server
Sun Fire 12K Server

COD, cpu, license, DR, activate, enable
Previously Published As
90205

Change History
Date: 2007-08-09
User Name: 71396
Action: Approved
Comment: Performed final review of article.
No changes required.
Publishing.
Version: 3
Date: 2007-08-07
User Name: 71396
Action: Accept
Comment:
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.