Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1005403.1 : Sun Fire[TM] 3800-6800/12K-E25K servers: Capacity on Demand (COD) How to activate CPU's into a domain?
PreviouslyPublishedAs 207524 Description After the licenses are ordered, delivered and entered into the Systems Controller configuration how do I bring the newly licensed CPU's into the domain configuration? Steps to Follow POST or HPOST evaluates the state of the licenses on the particular platform when it runs. stage_cpu_lpost(): No NMB Boards in config. Skipping Stage nmb_cpu_lpost.
Acquiring licenses for all good processors... Therefore in order to activate COD licenses into a domain POST needs to run. So we have the following options:
From the Systems controller: SC> addcodlicense verylonglicensestringhere SC> deleteboard SB1 SC> addboard SB1 From the domain: SC> addcodlicense verylonglicensestringhere DOMAIN> cfgadm -c disconnect SB1 DOAMIN> cfgadm -c configure SB1 On single board domains only option 1 can be used. Product Sun Fire V1280 Server Sun Fire E6900 Server Sun Fire E4900 Server Sun Fire E2900 Server Sun Fire 6800 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Sun Fire E25K Server Sun Fire E20K Server Sun Fire 15K Server Sun Fire 12K Server COD, cpu, license, DR, activate, enable Previously Published As 90205 Change History Date: 2007-08-09 User Name: 71396 Action: Approved Comment: Performed final review of article. No changes required. Publishing. Version: 3 Date: 2007-08-07 User Name: 71396 Action: Accept Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|