Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Technical Instruction Sure Solution 1017931.1 : Sun Fire[TM] 15K: Setting up SMS 1.2 "mld" service to receive domains syslog messages
PreviouslyPublishedAs 229192 Description Correctly setting up the System Management Software (SMS) 1.2 "mld" (message logging daemon) configuration to correlate to the domain OS "syslogd" configuration could help to alleviate a known SMS 1.2 "mld" memory leak condition. Steps to Follow The SMS "mld" service provides logging services to all SMS daemons and processes. "mld" is the first SMS daemon started by "ssd (1M)" in order to capture the output of all other SMS daemons and processes during their startup phases. Platform log messages are stored in: /var/opt/SUNWSMS/adm/platform/messages And domain log messages are stored in : /var/opt/SUNWSMS/adm/domain_id/messages The "mld" process on the system controller also receives syslog messages from the domains. Depending on the configuration of the "mld" process (via the mld.cf file) the messages are either logged or simply ignored. To alleviate an inherent issue with the SMS 1.2 "mld" service, where it could potentially run into a memory leak condition when processing incoming (from the domains' syslog) messages. We recommend correlating the SMS 1.2 "mld" configuration alignment with the domain OS "syslogd" configuration. Here is an example to correlate the "mld" service remote message reception configuration file contents against each specific domains syslog configuration. To align domain A's syslog configuration against "mld" remote messages reception setting for domain A as follows. On the System Controller (/etc/opt/SUNWSMS/config/mld.cf): *.err;kern.debug;daemon.notice;mail.crit /var/opt/SUNWSMS/adm/A/syslog In addition, the System Controller also uses the information housed in "/etc/opt/SUNWSMS/config/MAN.cf" file to document domain-to-SC, the SC-to-domain, and the SC-to-SC management network. For example, the MAN.cf documents the following IP address assignment for the SC-to-domain A I1 network connection : I1 SC-I1 v4u-15ka-sc-i1 192.168.103.1 Next, the "/etc/syslog.conf" on each domain resident in the Sun Fire[TM] 15K platform should be 'aligned' to the above mld.cf & MAN.cf configuration information. For example, based on the above SMS mld.cf and MAN.cf configuration, the domain A's /etc/syslog.conf should be as follows: *.err;kern.debug;daemon.notice;mail.crit @192.168.103.1 And the "syslogd" on the domains should be restarted (if any modifications were necessary on the domain OS's /etc/syslog.conf). Product Sun Fire 15K Server Internal Comments For internal Sun use only. See Bug 4784976 -- Received remote messages which are ignored by the "mld" process are not correctly freed but stay in memory of the "mld" process. sms, mld, syslog.conf, mld.cf, MAN.cf Previously Published As 71353 Change History Date: 2006-02-08 User Name: 71396 Action: Add Comment Comment: *** This is an automatic message. This document has received 0 hits in Sunsolve in 60 days (see http://krep.emea.sun.com/stats/dochistory.cgi?docid=71353 ). If it does not receive any hit in the next 30 days, it will be automatically archived. See http://kmo.central.sun.com/VAM/ for further details. *** Version: 0 Date: 2003-09-15 User Name: 97961 Action: Approved Comment: Correction mades. Reformatting and trademarking applied where appropriate. Version: 0 Date: 2003-09-12 User Name: 8727 Action: Approved Comment: Looks good Please publish Version: 0 Attachments This solution has no attachment |
||||||||||||
|