Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1006509.1
Update Date:2011-05-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  1006509.1 :   Sun Fire[TM] 12K/15K/E20K/E25K servers: System Controller, Solaris[TM] OS installation, and Solaris[TM] Volume Manager (SVM) Configuration  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
209107


Applies to:

Sun Fire 12K Server
Sun Fire 15K Server
Sun Fire E20K Server
Sun Fire E25K Server
All Platforms

Goal

The following procedure can be used to configure a Solaris[TM] installation and Solaris[TM] Volume Manager (SLVM) configuration on the System Controller when the System Controller (SC) disk must be completely rebuilt due to a failure.

Solution

How to configure Sun Fire[TM] 12K/15K/E20K/E25K servers:

1. As part of the Solaris installation, partition the disk at c0t2d0 following the partition tables:

Part        Size
0 8.00 GB /
1 4.00 GB swap
4 32.00 MB SLVM DB
5 32.00 MB SLVM DB
7 Avail. Free /export/install

Note: your previous installation of Solaris[TM] may have a two, four or four and a half gig swap space. All are supported, but new installations are recommended installing a four gig slice.


2. After the Solaris installation is complete, make sure the partition map on c0t3d0 is the same as c0t2d0. One method:

Run format
Select c0t2d0
Choose (p)artitions and name the map SCDISK
(q)uit the partition menu.
Choose (d)isks and select c0t3d0.
Choose (s)elect, pick SCDISK from the list presented and (l)abel the disk.
Exit format.

Or:

Run this command as root:
prtvtoc /dev/rdsk/c0t2d0s2 | fmthard -s - /dev/rdsk/c0t3d0s2


3. Install the SDS/SVM packages. (Note that SVM is bundled with Solaris 9 and higher)


4. Add the following to the end of the /etc/lvm/md.tab file.

mddb01   -c 3    c0t2d0s4
mddb02 -c 3 c0t2d0s5
mddb03 -c 3 c0t3d0s4
mddb04 -c 3 c0t3d0s5
d10 -m d11
d11 1 1 /dev/dsk/c0t2d0s0
d12 1 1 /dev/dsk/c0t3d0s0
d20     -m              d21
d21 1 1 /dev/dsk/c0t2d0s1
d22 1 1 /dev/dsk/c0t3d0s1
d30     -m              d31
d31 1 1 /dev/dsk/c0t2d0s7
d32 1 1 /dev/dsk/c0t3d0s7


5. Initialize the meta-databases with:

# metadb -a -f mddb01
# metadb -a mddb02
# metadb -a mddb03
# metadb -a mddb04


6. Remove the swap device.

# swap -d /dev/dsk/c0t2d0s1


7. Initialize the disk in the mirror and the mirror itself.

# metainit d21
# metainit d20


8. Add the new swap device and modify the /etc/vfstab file.

# swap -a /dev/md/dsk/d20
/dev/md/dsk/d20 - - swap - no -         vfstab entry


9. Unmount /export/install and initialize its disk and mirror.

# umount /export/install
# metainit d31
# metainit d30


10. Change /export/install's entry in /etc/vfstab to:

/dev/md/dsk/d30 /dev/md/rdsk/d30 /export/install ufs 2 yes logging 


11. Perform a newfs on /export/install and mount it.

# newfs -i 8192 -m 1 /dev/md/rdsk/d30
# mount /export/install


12. Prepare the disk and mirror for root.

# metainit -f d11
# metainit d10
# metaroot d10


13. REBOOT THE SYSTEM CONTROLLER.


14. Finally, synchronize the mirrors.

# metainit d12
# metattach d10 d12
# metainit d22
# metattach d20 d22
# metainit d32
# metattach d30 d32


Product
Sun Fire E25K Server
Sun Fire E20K Server
Sun Fire 12K Server
Sun Fire 15K Server

Internal Section

Keywords: SC, rebuild, failure, SLVM, starcat, 15k, 25k

Previously Published As 83103



Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.