Problem Document
|
Former IBIS ID
|
Synopsis
|
Last Modified Date
|
1017478.1 |
228592 |
OpenBoot[TM] PROM (OBP) watch-net-all test fails with "ethernet chip initialization failed" message |
2009-02-25
|
1011910.1 |
216303 |
Disabling erroneous messages created by src/p hardware raid card |
2009-09-17
|
1011808.1 |
216174 |
Sun Enterprise [TM] e250/450 only shows 3 out of 4 CPU's under psrinfo or prtdiag |
2010-08-27
|
1011637.1 |
215958 |
GBICs are not seen on a Sun Enterprise[TM]450 and Sun Enterprise[TM]250 |
2009-09-14
|
1010812.1 |
214941 |
Sun Enterprise[TM] 450 indicates Power Supply (P.S.) and cpu fan tray failed. |
2009-01-06
|
1010666.1 |
214730 |
Sun Enterprise[TM] 220R/420R:Symptom:Replacing Drive in SRC/P Hardware Raid results in redirected drive |
2009-09-15
|
1010236.1 |
214056 |
typo in setenv disk-led-assoc 0 x y command causes no display on Sun Enterprise[TM] 450 |
2009-09-20
|
1010184.1 |
213993 |
Determining use of the Operating Environment Installation CD (OECD) versus limit-ecache-size for Solaris[TM] 2.5.1 and 2.6 Operating System boot problems. |
2009-02-26
|
1010151.1 |
213940 |
Disks not being recognized in a Sun Enterprise[TM] 450 (9gb and 18Gb) |
2009-09-20
|
1008744.1 |
212006 |
Ultra[TM] 450 (U450) activity led blinks on one system and is steady on another...why? |
2009-09-27
|
1008645.1 |
211855 |
src/p card causes Sun Enterprise[TM] 450 to fail boot with upa-port error. |
2009-09-27
|
1008568.1 |
211707 |
Sun Enterprise[TM]450 only shows 4 disks under prtdiag |
2009-09-20
|
1007577.1 |
210483 |
Sun Enterprise[TM] 450 during power up OBP hangs, last message "Environmental monitoring: enabled" |
2009-09-21
|
1007465.1 |
210311 |
Do Sun Enterprise[TM] 450s support audio? |
2009-09-17
|
1007439.1 |
210274 |
16 LUN support for Clariion Array on PCI based system |
2009-09-17
|
1007391.1 |
210215 |
How to locate a failed disk on Sun Enterprise[TM] 450 using Sun StorEdge SRC/P Storage Manager[TM] |
2009-09-27
|
1005704.1 |
207904 |
The SAI/P card fails with tip. |
2009-09-24
|
1004782.1 |
206640 |
probe-scsi-all can see disks, but boot -r, devfsadm , and drvconfig, fail to add disks to OS |
2011-05-27
|
1004655.1 |
206454 |
Boot cdrom on a Sun Enterprise[TM] 450 with 480 MHz CPU Module fails with panic or Fast Data Access MMU (memory management unit) miss |
2009-09-20
|
1004624.1 |
206412 |
Finding a bad CPU in a Sun Enterprise[TM] 450 server |
2009-02-24
|
1004425.1 |
206114 |
Sun Enterprise[TM] 450 reports Ultra[TM] 450 instead of Enterprise 450 |
2009-06-23
|
1003523.1 |
204953 |
The Enterprise[TM] 450 system's CPU temperature is not within the acceptable range |
2009-02-12
|
1003233.1 |
204443 |
Sun[TM] Gigabit Ethernet 2.0 card config causes slow cpu speed at bootup on Ultra Enterprise[TM] |
2009-09-21
|
1003181.1 |
204367 |
Sun StorEdge[TM] A1000/RSM2000/Sonoma: Problem getting 16 lun support to work on PCI based systems |
2009-09-17
|
1003035.1 |
204157 |
Sun Enterprise Volume Manager[TM] (SEVM) 2.5/2.6: Running vxinstall on system with Sun StorEdge[TM] A5000 prompts for license |
2009-09-28
|