Solution Type Problem Resolution Sure Solution 1010812.1 : Sun Enterprise[TM] 450 indicates Power Supply (P.S.) and cpu fan tray failed.
PreviouslyPublishedAs 214941 Symptoms System fails to boot. These errors were displyed on system console: WARNING: Power supply fan 1 failure detected WARNING: CPU fan 0 failure detected WARNING: CPU fan 1 failure detected WARNING: CPU fan 2 failure detected Resolution Stated Action plan was to replace P.S. 1 1. Upon investigation all green LED's were on for all P.S.. No fault LED's were on for any P.S. 2. Following the action plan, P.S. 1 was swapped. The system still failed to boot. On the system console the same message displays: WARNING: Power supply fan 1 failure detected WARNING: CPU fan 0 failure detected WARNING: CPU fan 1 failure detected WARNING: CPU fan 2 failure detected 3. Next step was to replace the cpu fan tray. This resolved the issue. Additional Information 1. Check the LED's on the power supplies, if you see these errors on the console: WARNING: Power supply fan 1 failure detected WARNING: CPU fan 0 failure detected WARNING: CPU fan 1 failure detected WARNING: CPU fan 2 failure detected 2. If the Power Supplies green LED's are on and no fault LED are on, then replace the CPU fan tray first. This is more likely the problem. Product Sun Enterprise 450 Server Power Supply, P.S., failure, detected, CPU fan, cpu fan tray, E450, Sun Enterprise 450 Previously Published As 80707 Change History Date: 2005-03-21 User Name: 71396 Action: Approved Comment: Performed final review of article. Updated trademakring. Date: 2005-03-15 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2005-03-15 User Name: 27596 Action: Approved Comment: Reviewed Document. Attachments This solution has no attachment |
||||||||||||
|