Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1010666.1 : Sun Enterprise[TM] 220R/420R:Symptom:Replacing Drive in SRC/P Hardware Raid results in redirected drive
PreviouslyPublishedAs 214730 Symptoms Symptom: Replacing Drive in SRC/P Hardware Raid results in redirected drive. Product: SCSI RAID Controller (SRC/P) x-options 6542 / 6602 part number 375-0078 The redirected drive will appear in dptutil -L all /opt/SUNWhwrdg/dptutil -L all ... # b0 b1 b2 Controller Cache FW NVRAM Serial Status --------------------------------------------------------------------------- d0 c8 c6 c7 DPT PM3755U2B 64MB SMFE SUN V1.6 12-022003 Optimal Address Type Manufacturer/Model Capacity Status --------------------------------------------------------------------------- c8t0d0 Redirect DPT REDIRECT DRIVE 34732MB Optimal c6t0d0 Disk Drive (DASD) SEAGATE ST336704LSUN36G 34732MB Optimal c6t0d0 RAID 5 (Redundant DPT RAID-5 104195MB Optimal c7t3d0 Disk Drive (DASD) SEAGATE ST336704LSUN36G 34732MB Optimal c6t1d0 Disk Drive (DASD) SEAGATE ST336704LSUN36G 34732MB Optimal c6t2d0 Disk Drive (DASD) SEAGATE ST336704LSUN36G 34732MB Optimal c6t3d0 Disk Drive (DASD) SEAGATE ST336704LSUN36G 34732MB Optimal c7t0d0 RAID 5 (Redundant DPT RAID-5 69463MB Optimal c7t0d0 Disk Drive (DASD) SEAGATE ST336704LSUN36G 34732MB Optimal c7t1d0 Disk Drive (DASD) SEAGATE ST336704LSUN36G 34732MB Optimal c7t2d0 Disk Drive (DASD) SEAGATE ST336704LSUN36G 34732MB Optimal Address Max Speed Actual Speed Width --------------------------------------------------------------------------- c6t0d0 40 MHz 20 MHz wide c6t1d0 40 MHz 20 MHz wide c6t2d0 40 MHz 20 MHz wide c6t3d0 40 MHz 20 MHz wide c7t0d0 40 MHz 20 MHz wide c7t1d0 40 MHz 20 MHz wide c7t2d0 40 MHz 20 MHz wide c7t3d0 40 MHz 20 MHz wide
Resolution This document describes replacing Drive in SRC/P Hardware Raid results in redirected drive:
Product Sun Enterprise 220R Server Sun Fire 280R Server Sun Enterprise 450 Server Sun Enterprise 420R Server Sun Enterprise 250 Server src/p, raid, redirect, redirected, dptutil Previously Published As 74488 Change History Date: 2004-03-03 User Name: 13128 Action: Approved Comment: KE quality checklist applied - Publish Version: 0 Date: 2004-03-02 User Name: 13128 Action: Accepted Comment: Version: 0 Date: 2004-03-01 User Name: 25675 Action: Approved Comment: Excellent doc Version: 0 Date: 2004-03-01 User Name: 103982 Action: Approved Comment: here is the doc Dan told you about Version: 0 Date: 2004-03-01 User Name: 103982 Action: Created Comment: Version: 0 Change History Date: 2004-03-03 User Name: 13128 Action: Approved Comment: KE quality checklist applied - Publish Version: 0 Date: 2004-03-02 User Name: 13128 Action: Accepted Comment: Version: 0 Date: 2004-03-01 User Name: 25675 Action: Approved Comment: Excellent doc Version: 0 Attachments This solution has no attachment |
||||||||||||
|