Solution  1010151.1 :   Disks not being recognized in a Sun Enterprise[TM] 450 (9gb and 18Gb)  


Related Items
  • Sun Enterprise 450 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
213940


Symptoms
When trying to mix 9gb and 18gb disks internally in an e450,
the new 18gb disks are not being recognized.

Resolution
The 18gb disks must be pushed gently, but with a good amount
of force to make them fully connect with the disk backplane.
It helps to put the e450 up against a solid object when pushing
the disks in.

Product
Sun Enterprise 450 Server

Previously Published As
21478

Change History
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : Laurie Hutchins
comment : Verified technically accurate by Hardware-systems.
Reviewed and editied by KE.
date : Jun 7, 2000



updated by : Karen Vergakes
comment : Doc is ok.
date : May 30, 2000



updated by : No owner
comment : Not entered
date : Dec 23, 1999
Version: 0
Product_uuid
29656238-0a18-11d6-91d9-a4e449afd809|Sun Enterprise 450 Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.