Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1004655.1 : Boot cdrom on a Sun Enterprise[TM] 450 with 480 MHz CPU Module fails with panic or Fast Data Access MMU (memory management unit) miss
PreviouslyPublishedAs 206454 Symptoms Booting a Solaris[TM] 2.5.1 11/97 CDROM on an Enterprise 450 with 480 MHz CPU Module fails with error: Fast Data Access MMU (memory management unit) Miss Booting a Solaris[TM] 2.6 FCS through 2.6 HW 5/98 CDROM on an Enterprise 450 with 480 MHz CPU Module fails with error: panic[cpu]/thread=0x10404040: mutex_enter: bad mutex Resolution The Enterprise 450 with the 480MHz cpu module are not supported under any version of 2.5.1. The minimum supported Solaris 2.6 version is HW 5/98. It will install with 02/00 Operating Environment CD because it incorporates kernel Patch ID 105181-19 but will not install with previous OECD versions. The minimum supported Solaris[TM] 7 version is HW 11/99. Product Sun Enterprise 450 Server Boot cdrom, Sun Enterprise 450, 480 MHz CPU Module, panic, Fast Data Previously Published As 24408 Change History Date: 2007-06-07 User Name: 84816 Action: Update Canceled Comment: *** Restored Published Content *** No update needed. Version: 0 Date: 2005-03-03 User Name: 84816 Action: Update Started Comment: Test Version: 0 Attachments This solution has no attachment |
||||||||||||
|