Solution Type  Problem Resolution Sure

Solution  1004655.1 :   Boot cdrom on a Sun Enterprise[TM] 450 with 480 MHz CPU Module fails with panic or Fast Data Access MMU (memory management unit) miss  


Related Items
  • Sun Enterprise 450 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
206454


Symptoms
Booting a Solaris[TM] 2.5.1 11/97 CDROM on an Enterprise 450 with 480 MHz CPU Module fails with error:
Fast Data Access MMU (memory management unit) Miss

Booting a Solaris[TM] 2.6 FCS through 2.6 HW 5/98 CDROM on an Enterprise 450 with 480 MHz CPU Module fails with error:

panic[cpu]/thread=0x10404040: mutex_enter: bad mutex



Resolution
The Enterprise 450 with the 480MHz cpu module are not supported under any version of 2.5.1.
The minimum supported Solaris 2.6 version is HW 5/98. It will install with 02/00 Operating Environment CD because it incorporates kernel Patch ID 105181-19 but will not install with previous OECD versions.

The minimum supported Solaris[TM] 7 version is HW 11/99.



Product
Sun Enterprise 450 Server

Boot cdrom, Sun Enterprise 450, 480 MHz CPU Module, panic, Fast Data
Previously Published As
24408

Change History
Date: 2007-06-07
User Name: 84816
Action: Update Canceled
Comment: *** Restored Published Content *** No update needed.
Version: 0
Date: 2005-03-03
User Name: 84816
Action: Update Started
Comment: Test
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback