Solution Type  Problem Resolution Sure

Solution  1008568.1 :   Sun Enterprise[TM]450 only shows 4 disks under prtdiag  


Related Items
  • Sun Enterprise 450 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
211707


Symptoms
When users run prtdiag -v on the Enterprise 450
fully configured with disks they  can only see a max of 4 disks e.g.
Disk LED Status:	OK = GREEN	ERROR = YELLOW
		DISK 18: [EMPTY]	DISK 19: [EMPTY]
		DISK 16: [EMPTY]	DISK 17: [EMPTY]
		DISK 14: [EMPTY]	DISK 15: [EMPTY]
		DISK 12: [EMPTY]	DISK 13: [EMPTY]
		DISK 10: [EMPTY]	DISK 11: [EMPTY]
		DISK  8: [EMPTY]	DISK  9: [EMPTY]
		DISK  6: [EMPTY]	DISK  7: [EMPTY]
		DISK  4: [EMPTY]	DISK  5: [EMPTY]
		DISK  2:    [OK]        DISK  3:    [OK]
		DISK  0:    [OK]	DISK  1:    [OK]


Resolution
From the OBP prompt:
ok setenv disk-led-assoc 0 x y
where x= 1 to 10 PCI slot where the lowest Ultrascsi cont is installed
where y= 1 to 10 PCI slot where the uppermost Ultrascsi cont is installed
				
For example, if ctrl cards are in slot 5 and 7 enter the following:
ok setenv disk-led-assoc 0 5 7
if there is only one ctrl installed in slot 5
ok setenv disk-led-assoc 0 5
ok reset
ok boot -r to take effect
Now run prtdiag -v
Disk LED Status:        OK = GREEN      ERROR = YELLOW
DISK 18:    [OK]        DISK 19:    [OK]
DISK 16:    [OK]        DISK 17:    [OK]
DISK 14:    [OK]        DISK 15:    [OK]
DISK 12:    [OK]        DISK 13:    [OK]
DISK 10:    [OK]        DISK 11:    [OK]
DISK  8:    [OK]        DISK  9:    [OK]
DISK  6:    [OK]        DISK  7:    [OK]
DISK  4:    [OK]        DISK  5:    [OK]
DISK  2:    [OK]        DISK  3:    [OK]
DISK  0:    [OK]        DISK  1:    [OK]


Product
Sun Enterprise 450 Server

Previously Published As
16524

Change History
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : Laurie Hutchins
comment : Verified technically accurate by Hardware-systems.
Reviewed and edited by KE.
date : Jun 1, 2000



updated by : Karen Vergakes
comment : Doc is techinal ok.
date : May 24, 2000



updated by : Thom Chumley
comment : Changed to SRDB and issued
date : Feb 9, 1998
Version: 0
Product_uuid
29656238-0a18-11d6-91d9-a4e449afd809|Sun Enterprise 450 Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback