Solution Type  Problem Resolution Sure

Solution  1008645.1 :   src/p card causes Sun Enterprise[TM] 450 to fail boot with upa-port error.  


Related Items
  • Sun Enterprise 450 Server
  •  
  • Sun Enterprise 250 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
211855


Symptoms
Enterprise 450 is loaded with Solaris[TM] 2.x and is fully functional.
The src/p IO card is added to the appropriate slot in the back of
the 450, and cabled to the middle 8 drive back plane of the array
The addition of the card is verified at the Open Boot Prom level.
Diagnostics such as "probe-scsi-all" and "obdiag" appropriately
identify the card. However reboot of the system now fails with:
warning: pci6:no upa-port id property
The only way to get the system to boot again is to remove the
card from the slot.


Resolution
The problem is solved at the OBP level. The minimum PROM revision
required for the src/p card is 3.12.12. In this particular case, the
PROM version was 3.5. By installing patch 106122-06 (or later) and
upgrading the PROM to the latest level, (in this case 3.16.2), the
system booted up normally.

Note: the same PROM requirement exist for the E250. The PROM upgrade
patch is 106503-04 or later.

Product
Sun Enterprise 450 Server
Sun Enterprise 250 Server

Previously Published As
23897

Change History
Date: 2006-01-19
User Name: 31620
Action: Update Canceled
Comment: *** Restored Published Content *** SSH AUDIT
Version: 0
Date: 2006-01-19
User Name: 31620
Action: Update Started
Comment: SSH AUDIT
Version: 0
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : Daniel Caporale
comment : Article created.
date : Sep 29, 2000



updated by : Daniel Caporale
comment : No comment
date : Sep 29, 2000



updated by : Howard Lapin
comment : No comment
date : Sep 29, 2000



updated by : Howard Lapin
comment : No comment
date : Sep 29, 2000



updated by : Wendy Bean
comment : No comment
date : Sep 29, 2000
Version: 0
Product_uuid
29656238-0a18-11d6-91d9-a4e449afd809|Sun Enterprise 450 Server
2962179a-0a18-11d6-845c-9c8399e8b5f2|Sun Enterprise 250 Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback